Tpp Tissue Culture Flasks With Peel-off Foil Instruction Manual

Tissue Culture Flasks with Peel-off Foil

Product Information

The TPP Tissue Culture Flasks with Peel-off Foil are designed
for cell culture with sterile handling techniques, storage, and
microscopy. These flasks have an optomechanically activated growth
surface to optimize cell adhesion and proliferation. The angled
flask neck helps reduce the risk of medium contact with the inside
of the screw cap.

These flasks are available with filter screw caps only. It is
important to note that using a VENT screw cap may cause pressure
build-up, which could press open the peel-off foil.

The TPP Tissue Culture Flasks with Peel-off Foil are intended
for single-use only. It is recommended to follow national
regulations for handling biological material and use appropriate
protective clothing.

Product Usage Instructions

  1. Check the packaging material and the product for intactness.
    Use only faultless packaging.
  2. Open the packaging in a sterile environment and remove a
    complete system for use.
  3. Open the filter screw cap of the cell culture flask.
  4. Fill the flask with medium and inoculum according to your
    standard laboratory routine.
  5. Resuspend the cells well with the medium to avoid cell
    lumps.
  6. Avoid foaming during resuspension and seeding to prevent holes
    in the cell layer.
  7. Ensure an appropriate medium volume to avoid meniscus formation
    and uneven growth of cells. Refer to the technical data for the
    optimum filling volume.
  8. If stacking multiple flasks in an incubator, air vents in the
    bottom rim ensure optimum heat distribution.
  9. When centrifuging the flasks, consider factors such as shape,
    material, accuracy of fit in the centrifuge adapter, temperature,
    centrifugation time, and g-number to maintain mechanical
    strength.

Please note that TPP products are for research use only and not
intended for use in clinical, diagnostic, or therapeutic
procedures. TPP does not assume any guarantee for damages and
defects resulting from unregistered or improper use. These
instructions should be considered as guidelines, and TPP accepts no
responsibility for the topicality, accuracy, completeness, or
quality of this information.

Instruções de uso Frasco de cultura celular com
película removível TPP

Instructions for Use TPP Tissue Culture Flasks with
Peel-off Foil

Os frascos de cultura celular TPP com película removível são projetados para o cultivo e crescimento de células com um único acesso a partir do topo. Somente o fundo do frasco é opto-mecanicamente ativado para uma ótima aderência e crescimento celular. O gargalo angular da garrafa reduz o risco de contato médio com o interior da tampa rosqueável com filtro por derramamento.
Estes frascos de cultura celular TPP estão disponíveis apenas com tampa rosqueável com filtro. Ao utilizar uma tampa rosqueável com VENT, uma possível acumulação de pressão de 0,03 bar ou superior poderia pressionar a película removível. O frasco de cultura celular TPP com película removível é destinado a uso único.

TPP tissue culture flasks with peel-off foil are designed for cell culture with necessary sterile handling techniques, storage and microscopy in manual use and to meet the need for a large one-time access from the above to the cell culture. The growth surface is optomechanically activated to optimize cell adhesion and proliferation. The angled flask neck reduces the risk of medium contact with the inside of the screw cap.
TPP cell culture flasks with peel-off foil are available with filter screw caps only, when using a VENT screw cap a possible pressure build-up of 0.03 bar or higher could press open the peel-off foil.
The TPP tissue culture flask with peel-off foil is intended for single use only.

Dica:

Note:

Observar as regulamentações nacionais para o manuseio de material biológico, usar a roupa de proteção apropriada.

Follow national regulations when handling biological material, use appropriate protective clothing

Observar as regras do trabalho asséptico em todas as etapas.

Take note of the regulations of aseptic working during the work process.

Instruções:

Instructions:

Verificar o material de embalagem e o

Check the packaging material and the

produto quanto a danos. Usar somente

product for intactness. Use only faultless

material em perfeitas condições.

material.

Verificar a data de validade (EXP) no rótulo e Check the expiry date (EXP) on the label and

na embalagem. Utilizar somente produtos

packaging. Only use products with valid EXP

com EXP válido.

Open the packaging in a sterile environment

Abra a embalagem em um ambiente estéril

and remove a complete system for use.

e remova um sistema completo para uso. Open the filter screw cap of the cell culture

Abra a tampa rosqueável com filtro do

flask and fill the flask with medium and

frasco de cultura celular e encha o frasco

inoculum according to your standard

com meio e inóculo de acordo com a rotina

laboratory routine.

normal do laboratório.

Source: TPP/literature

1 / 4

Version 01_2022

Note: TPP products are for research use only and not intended for use in clinical, diagnostic or therapeutic procedures. TPP does not assume any guarantee for damages and defects resulting from unregistered or improper use.

TPP recommendations are guidelines and do not represent an absolute value. TPP accepts no responsibility for the topicality, accuracy, completeness or quality of this IFU.

Feche completamente a tampa rosqueável Close the filter screw cap completely. A

com filtro. A membrana filtrante PTFE

continuous gas exchange takes place

hidrofóbica integrada 0,22 µm garante a

through the integrated hydrophobic

troca contínua de gás. Se a membrana ficar

membrane 0.22 µm. If the PTFE filter

molhada, a troca de gás é reduzida por um

membrane gets wet, the gas exchange is

curto período.

reduced for a short time.

Cultivar e colher as células de acordo com a Cultivate and harvest cells according to your

rotina laboratorial habitual.

common laboratory routine.

Para obter um crescimento uniforme na

superfície, os seguintes aspectos devem ser To achieve an uniform cell growth, the

observados:

following aspects must be observed:

o Resuspender bem as células com o meio

o Resuspend the cells well with the

para evitar grumos de células.

medium to avoid cell lumps.

o Evitar a formação de espuma durante a

o Avoid foaming during resuspension and

resuspensão e a semeadura para obter

seeding to avoid holes in the cell layer.

uma superfície uniforme de células.

o Low medium volume leads to meniscus

o O baixo volume médio leva à formação

formation and thus to uneven growth of

de menisco e, portanto, ao crescimento

the cells (cell clumps at the edge). Please

desigual das células (tufos de células nas

refer to the technical data for the

bordas). Consulte os dados técnicos para

optimum filling volume.

obter o volume ideal de enchimento. Air vents in the bottom rim ensure optimum

As aberturas de ar na borda da base

heat distribution in the incubator when

garantem uma ótima distribuição de calor

several flasks are stacked on top of each

na incubadora quando várias garrafas são

other.

empilhadas umas sobre as outras.

The mechanical strength of the flasks during

A capacidade de carga mecânica das

centrifugation is influenced by

garrafas durante a centrifugação é

o Shape and material

influenciada por:

o Accuracy of fit in the centrifuge adapter

o Formato e material

o Temperature, centrifugation time,

o Precisão de ajuste no adaptador da

g-number

centrífuga

o Chemical and physical properties of the

o Temperatura, tempo de centrifugação,

centrifuged material

força g

o Rotor type: fixed-angle or swing-out

o Propriedades químicas e físicas do

rotor

material centrifugado

Test the multitude of influencing factors

o Tipo de rotor: rotor de ângulo fixo ou

under routine conditions beforehand.

rotor basculante

Storage before use at room temperature,

Primeiro teste a multiplicidade de fatores de protect from UV light.

influência sob condições de rotina.

Armazenar à temperatura ambiente antes

de usar, proteger da luz UV.

Source: TPP/literature

2 / 4

Version 01_2022

Note: TPP products are for research use only and not intended for use in clinical, diagnostic or therapeutic procedures. TPP does not assume any guarantee for damages and defects resulting from unregistered or improper use.

TPP recommendations are guidelines and do not represent an absolute value. TPP accepts no responsibility for the topicality, accuracy, completeness or quality of this IFU.

Retirar a película removível:

Peel-off the Peel-Off Foil:

A colheita das células pode ser feita de cima The cell harvest from chamber can be

para baixo através da película removível.

carried out from above when the peel-off foil

Posicione o polegar e o localizador central

is removed.

nos campos de etiquetagem da garrafa T. Position thumb and middle finger on the

Estabilize a garrafa com seu dedo indicador,

inscription fields on both sides of the neck of

colocando-a sob a aba da película removível

the T-flask. Use your index finger to press

e pressionando a garrafa sobre a superfície.

the flask onto the surface by placing the

Segure a aba da película com sua outra mão

fingertip underneath the foil flab, thus

e puxe a aba para trás com um leve puxão.

stabilizing the flask. Grab the foil flap with

Não é possível fechar novamente a película

the other hand and pull the foil back with a

removível.

gentle pull.

It is not possible to reclose the foil.

Comentários e recomendações:

Advice and Recommendations:

Há campos de rotulagem em ambos os lados For labelling there are inscription fields on

para marcação.

both sides of the flask.

A graduação serve como uma indicação da The graduation serves as a reference for the

quantidade de enchimento e não é um valor

filling quantity and is not an absolute value.

absoluto.

The stacking rim allows a stable stacking of

O aro de empilhamento permite uma

several flasks on top of each other, also in

estabilidade segura de várias garrafas

combination with other TPP flasks of the

empilhadas umas sobre as outras, também

same size.

em combinação com outros frascos de

For a homogenous cultivation of the cells,

cultura de células TPP do mesmo tamanho.

levelling of the incubator and continuous

Para o cultivo uniforme das células, é

supply of medium is essential.

essencial o nivelamento da base e o

Avoid and/or eliminate vibration sources

fornecimento regular do meio nutriente.

near the incubator to ensure uniform cell

Evite fontes de vibração perto da

growth

incubadora para garantir o crescimento

uniforme das células.

Nota: A barreira limita a área de crescimento a 115 cm2.

Note: The barrier limits the growth area to 115 cm2.

Source: TPP/literature

3 / 4

Version 01_2022

Note: TPP products are for research use only and not intended for use in clinical, diagnostic or therapeutic procedures. TPP does not assume any guarantee for damages and defects resulting from unregistered or improper use.

TPP recommendations are guidelines and do not represent an absolute value. TPP accepts no responsibility for the topicality, accuracy, completeness or quality of this IFU.

Dados técnicos:
Materiais Frasco Tampa rosqueável Membrana
Película

PS PE PTFE tamanho dos poros 0.22 µm Sem toxinas

Technical Data:
Materials Flask Screw cap Membrane
Foil

PS PE PTFE pore size 0.22 µm
toxin-free foil

Dimensões Película removível Barreira Comprimento mm Largura mm Altura mm Área de crescimento cm2 Volume Recom. mL Abertura mm Volume máximo mL

Measurement Peel-off foil Barrier Length mm Width mm Heights mm Growth area cm2
Recom. volume mL Opening mm Max volume mL

90028 –92 51 31
25
3 ­ 8 38 x 45
15

90078 –155 87 45
75
8 ­ 22 87 x 92
65

90153 –210 122 50
150
15 ­ 45 100 x 128
100

90303 –275 170 55
300
30 – 85 140 x 185
200

90653 210 122 50
115
15 ­ 33 100 x 128
100

Adicional:

Additional:

Instruções de uso, listas de resistência química, certificados de qualidade dos respectivos produtos estão disponíveis para download na homepage www.tpp.ch.

Instructions for use, chemical resistance lists, and quality certificates of the respective products are available for download on the homepage www.tpp.ch .

Source: TPP/literature

4 / 4

Version 01_2022

Note: TPP products are for research use only and not intended for use in clinical, diagnostic or therapeutic procedures. TPP does not assume any guarantee for damages and defects resulting from unregistered or improper use.

TPP recommendations are guidelines and do not represent an absolute value. TPP accepts no responsibility for the topicality, accuracy, completeness or quality of this IFU.

References

Documents / Resouces

Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.


Related Manuals