ACS R/RP to a Bennett EIC 5000 Trim System
Product Information: ACS R/RP
The ACS R/RP is a system that can be connected to a Bennett EIC
5000 trim system. It requires the removal of the original control
panel and control unit. The ACS R/RP is connected directly to
terminals 3,4,5,6 which are connected directly to the pump. The
supply to the old control unit (Orange/red +, black -) can be used
for the ACS. The black wire from the pump needs to be grounded.
Product Usage Instructions
- Remove the original control panel and control unit from the
Bennett EIC 5000 trim system. - Connect the ACS R/RP to terminals 3,4,5,6 which are connected
directly to the pump. - Use the supply to the old control unit (Orange/red +, black -)
for the ACS. - Make sure the black wire from the pump is grounded.
- After installation, refer to the user manual and verify the
control direction according to instructions.
ACS R/RP
Bennett EIC 5000 connection
Connecting the ACS R/RP to a Bennett EIC 5000 trim system
The terminals 3,4,5,6 are connected directly to the pump. The original control panel and control unit have to be removed. The supply to the old control unit ( Orange/red +, black – ) maybe be used for the ACS. Make sure the black wire from the pump is grounded. After installation, please verify the control direction according to instructions in the user’s manual.
1 23 45 6 7
Control panel (Removed)
20A(F) (+) (-)
Cut here
(-)
Control unit (Removed)
Mente Marine Ltd Vaasa, Finland www.mente-marine.com