HD-BD88 ECO Friendly
Product Information:
Product Name: Bluedry
Model: HD-BD88
Technical Specifications:
- Item Category: Hand Dryer
- Operating Voltage: 220 – 240Vac, 50Hz, 880 WATTS
- Warm Air Speed Output: 103 m/s
- Noise Level: 78dBA @ 1 meter
- Motor Type: 650 Watts, 23,000 rpm, Brush Type, Dual Ball
Bearings - Heater Element: 230W
- Drying Time: Less than 15 seconds
- Circuit Operation: Infrared Automatic, self-adjusting
- Sensor Range: 100 mm
- Timing Protection: 60 seconds auto shut off
- Drip Proof: IP22
- Isolation: CLASS 11 double insulated
- Net Weight: 4.5 kg
- Shipping Weight: 5 kg
- Unit Size: 255mm W x 525mm H x 172mm D
- Finish: ABS Silver – HD-BD88S, ABS White – HD-BD88W
Product Usage Instructions:
General Safety Information:
- Ensure proper grounding of the unit to avoid electrical
shock. - This product should be installed by a qualified service
person. - Disconnect power at the service breaker before installing or
servicing. - Not for household use as it may cause burns.
- Do not install the dryer over a wash basin.
- If the power supply cord is damaged, it must be replaced by the
manufacturer, its service agent, or a qualified person. - Means for disconnection must be incorporated in the fixed
wiring as per the wiring rules.
Recommended Mounting Heights:
From floor to bottom of air outlet:
- Men’s: 43 inches (109 cm)
- Ladies: 41 inches (104 cm)
- Children, ages 11-17: 39 inches (99 cm)
- Children, ages 3-10: 33 inches (84 cm)
- Disabled: 35 inches (89 cm)
Installation:
- Ensure the power supply breaker is switched off.
- Place the template against the wall at the desired height and
mark the locations of the 4 mounting holes and wire service
entry. - Connect the supply wires to the terminal block as indicated and
connect the ground wire to the baseplate with the ground
screw. - Replace the cover, but do not over-tighten the screws.
- Fix the water tank to the hand dryer using the provided
screws. - Make a breach on the cover according to the position of the
power cord coming out before pulling out the power cord. Hang the
dryer on the hanger board and fix the water tank at the bottom with
the screws. - Drill three holes of 6mm diameter.
- If the unit overruns or does not work after installation,
adjust the induction sensibility.
NO DLY
EC FRIE
BLUEDRY USER MANUAL
Model HD-BD88
1. TECHNICAL SPECIFICATIONS
525mm
255mm
172mm
Item Category
Performance Data
Operating Voltage
220 – 240Vac, 50Hz, 880 WATTS
Warm Air Speed Output 103 m/s
Noise Level
78dBA @ 1 meter
Air Output Temperature 77°F (25°C) – Ambient Temperature 68°F (20°C)
Motor Type
650 Watts, 23,000 rpm, Brush Type, Dual Ball Bearings
Motor Thermal Protection Auto Resetting Thermostat turns unit off, 240V at 221°F (105°C) – EURO Spec
Heater Element
230W
Heater Thermal Protection Auto Resetting Thermostat turns unit off at, 149°F (65°C)
Drying Time
Less than 15 seconds
Circuit Operation
Infrared Automatic, self adjusting
Sensor Range
100 mm
Timing Protection
60 seconds auto shut off
Drip Proof
IP22
Isolation
CLASS 11 double insulated
Net Weight
4.5 kg
Shipping Weight
5 kg
Unit Size
255mm W x 525mm H x 172mm D
Finish
ABS Silver – HD-BD88S ABS White – HD-BD88W
2. GENERAL SAFETY INFORMATION
· WARNING
Failure to properly ground unit could result in electrical shock and/or death.
This product is intended for installation by a qualified service person. Use AWAG No.16 solid conductor for wiring.
Disconnect power at the service breaker before installing or servicing. NOT FOR HOUSEHOLD USE – MAY CAUSE BURNS
NOTE: Do not install dryer over wash basin.
Type Y attachment
If the power supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person in order to avoid a hazard.
Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules.
3. RECOMMENDED MOUNTING HEIGHTS
From floor to bottom of air outlet.
Men’s
Ladies
Children, ages 11-17 Children, ages 3-10 Disabled
43″
41″
39″
33″
35″
109 cm
104 cm
99 cm
84 cm
89 cm
4. INSTALLATION
Installation must be carried out by a qualified electrician
1. Make sure power supply breaker is switched off. Installation must be carried out in accordance with the current edition of the local wiring regulations code having jurisdiction. Installation should be performed only by a qualified electrician.
2. Place template against wall at desired height (see mounting height recommendations) and mark locations of 4 mounting holes and wire service entry at knockout (KO) location.
4. Connect supply wires to terminal block where indicated and connect ground wire to baseplate with ground screw.
Connections:
a. Connect the live wire (coloured red or brown) to the terminal block marked “L”.
b. Connect the neutral wire (coloured black or blue) to the terminal block marked “N”.
Note that the colour of live and neutral wires depends on voltage of supply service.
NOTE: Two or more dryers should be no
5. Replace cover. Do not over-tighten
closer than 24 inches (610 mm) on centre. screws.
3. Remove and retain 2 cover screws and cover.
5. INSTALLATION CONT.
1. Fix the water tank to the hand drier with the screws attached.
4. Make a breach on the cover according to the position of the power cord coming out before pulling out the power cord. Follow arrow A, hang the drier on the hanger board. Follow the arrow B, pull out the water tank and fix the hole at the bottom with the screws attached. Put back the water tank.
2. Drill three holes of 6mm diameter.
5. In order to meet different installation environments the induction sensibility is set at the most sensitive point. If this unit over runs or does not work after installing, please adjust
3. Fix the hanging board to two holes which are at the top by using the plugs and screws.
6. CLEANING & MAINTENANCE
Check the water tank 1-2 times a week and empty before it reaches the full mark.
DO NOT use caustic solutions or abrasive cleaning materials on the drier.
Take out the air filter mesh from this appliance, clean it once a week and refix.
All surfaces of the unit should be cleaned daily with a soft cloth dampened with warm, soapy water. Polish with a soft dry cloth.
7. DIAGRAM
8. PARTS LIST
1 Power indicator light 2 Front cover 3 Motor housing 4 Rubber washer 5 Shock absorber 6 Motor rubber 7 Motor and fan module 8 Blower housing base plate 9 Blower housing cover 10 Terminal block 11 Cable clamp 12 Base plate 13 Wall fixing bracket 14 Circuit board module
15 Water tank 16 Wall fix bracket 17 Water tank cover 18 Water tank 19 Air outlet gasket 20 Heating element 21 Air outlet 22 Fixing screw 23 Bottom plate 24 Filter 25 Sensor PCB module 26 Sensor screen 27 Front cover flange












![Breville 3x Bluicer Pro [bjb815] User Manual Breville 3x Bluicer Pro [bjb815] User Manual](https://static-data1.manualsee.com/1/img/77/17011/2020/12/00-16.jpg)