XPT01E1433 Wireless Sensor Translator
Product Information
The Wireless Translator by Sybersense IoT allows you to reuse
existing Honeywell & 2GIG wired or wireless sensors with the
Sybersense Panel. It is compatible with XP02/XP06 Security Panels
and can convert the 345MHz signal to a 433MHz signal for wireless
sensors. The Translator supports 2 wired sensors and has a unique
Wireless ID for each zone. It also supports all sensor alarm,
supervisory, and trouble signals, as well as Sybersense DHM system
and Cover Tamper. The Translator has dual antennas to increase
transmit and receive range and operates on a backup battery.
Product Features
- Listens to 2G1G and Honeywell 345MHz radio frequency protocol
wireless sensors. - Converts to 433MHz radio frequency protocol via the Translator
(does not support repeater). - Compatible with XP02/XP06 Security Panels.
- Unique Wireless ID for each Zone.
- Supports 2 wired sensors.
- Supports all sensor alarm, supervisory, and trouble
signals. - Supports Sybersense DHM system.
- Supports Cover Tamper.
- Dual Antennas to increase Transmit and Receive range.
- Backup Battery Operation.
Product Specification
- Wireless Signal Range: RX 150 Meters, TX 200 Meters (To be
Verified, Open area) - Transmitter Frequency: Rx 345MHz, Tx 433MHz
- Modulation: OOK
- Encrypted: 345Mhz unencrypted signal to 433MHz encrypted
signal - 2-way support: Yes
- Frequency Hoping: No
- Supervisions: Yes
- Heartbeat Interval: 60 minutes
- Tamper: Yes
- Wired Support: Yes
- Battery: Built-in 2000mAh 3.7V Li battery
- Battery Life Adaptor: 24 hours minimum for Non-Powered Zones, 4
hours minimum for Powered Zones - DC Jack: 12VDC 1A, 100-240VAC 50/60Hz, UL certificated
- Current Draw: Output 12VDC Max. 80mA for wired sensors
(TBC) - Water Resistance: No
- Operating Temperature: 0 ~ 49°C
- Relative Humidity (Storage): 80% Max. non-condensing
- Sensor Dimensions: 116mm * 115mm * 26mm
- Certification: FCC, IC
Product Usage Instructions – Pairing with the Security
Panel
- Enter Settings in the Panel.
- Select Devices and click + at the top right corner.
- Select the Translator device to add.
- Open the case and trigger the Tamper.
- Select a location for the sensor.
- Review the installation guide and confirm Done. The new
Translator is added.
LED Indicator
| LED | Power Mode | Meaning |
|---|---|---|
| LED Power | Green | On/Flash/Off |
| Configure | Blue | On/Off |
| Translator Mode | ||
| Flash | Ready to add a sensor to panel via the translator. | |
| Adding Mode | Green | Flash/Off |
| Flash | Received a signal for adding a sensor. | |
| Duplicated Mode | Red | Flash/Off |
| Flash | The Panel tells the Translator that it is sending an already added sensor signal to Panel. And Panel shows the duplicated SN on the screen (tbd). |
Translator User Guide
PTG – Product Sybersense IoT Co., Ltd
Confidential. Sybersense IoT Co., Ltd
1
1. Introduction
The Wireless Translator allows you to reuse the existing Honeywell & 2GIG wired or wireless sensors with Sybersense Panel (refer to the compatible sensor list). For wireless sensors, it can switch the 345MHz signal to 433MHz signal. It can power wired sensors and add them directly into the Sybersense new system via the translator terminals.
2. Included Material
Translator*1 Wall screw*2 Expansive rubber sleeve*2
3. Product Appearance
115mm
Power Rx Tx
116mm
4. Product Features
Listens to 2G1G and Honeywell 345MHz radio frequency protocol wireless sensors.
Convert to 433Mhz radio frequency protocol via the Translator (doesn’t support repeater)
Compatible with XP02/XP06 Security Panels.
Unique Wireless ID for each Zone
Confidential. Sybersense IoT Co., Ltd
2
Support 2 wired sensors. Support all sensor alarm, supervisory and trouble signals. Support Sybersense DHM system Support Cover Tamper. Dual Antennas to increase Transmit and Receive range Backup Battery Operation
5. Product Specification
Wireless Signal Range Transmitter Frequency
RX 150 Meters, TX 200 Meters (To be Verified, Open area) (*Note)
Rx 345MHz, Tx 433MHz
Modulation
OOK
Encrypted
345Mhz unencrypted signal to 433MHz encrypted signal
2 way support
Yes
Frequency Hoping
No
Supervisions
Yes
Heartbeat Interval
60 minutes
Tamper
Yes
Wired Support
Yes
Battery
Built-in 2000mAh 3.7V Li battery
Battery Life Adaptor
24 hours minimum for Non-Powered Zones 4 hours minimum for Powered Zones
DC Jack,12VDC 1A, 100-240VAC 50/60Hz, UL certificated
Current Draw
Output 12VDC Max. 80mA for wired sensors (TBC)
Water Resistance Operating Temperature
No 0 ~ 49
Relative Humidity (Storage)
80% Max. non-condensing
Sensor Dimensions
116mm * 115mm * 26mm
Certification
FCC, IC
*Note: 1) The XPT01 is facing the panel LCD. 2) The panel is installed at the height of 1.5 meters. The XPT01 is placed at the height of 1.2 meters. 3)RX Wireless Signal Range: Related to sensor RF Performance 3) Open Area, the location of the sensor can have a significant effect on range. In open/unobstructed situation, the transmitter range may be greater. In adverse wireless condition, you may encounter a decrease in range.
Confidential. Sybersense IoT Co., Ltd
3
6. Pairing with the Security Panel
(1) Enter Settings in Panel.
(4) Open the case and trigger the Tamper.
(2) Select “Devices”. Click “+” at the right up corner.
(5) Select a location for the sensor.
(3) Select the Translator device to add.
(6) Review the installation guide and confirm “Done”. The new Translator is added.
7. LED Indicator
LED Power
LED Pattern Green On/Flash/Off
Translator Mode Power Mode
Meaning
On: Translator DC and Battery connected. Flash: Translator DC or battery disconnected.
Configure Blue On/Off
Enroll Mode
Flash: Ready to add a sensor to panel via the translator.
Green Flash/Off
Adding Mode
Flash: Received a signal for adding a sensor.
Red Flash/Off
Duplicated Mode
Flash: The Panel tells the Translator that it is sending an already added sensor signal to Panel. And Panel shows the duplicated SN on the screen (tbd).
Rx
Blue Flash/Off
Rx Mode
Flash: Receiving a sensor’s signal (s)
Tx
Red Flash/Off
Confidential. Sybersense IoT Co., Ltd
Tx Mode
Flash: Transmitting asensor’s signal (s) to the panel. 4
FCC Warning
§ 15.19 Labeling requirements. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
§ 15.21 Information to user. Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
§ 15.105 Information to the user.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: –Reorient or relocate the receiving antenna. –Increase the separation between the equipment and receiver. –Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. –Consult the dealer or an experienced radio/TV technician for help.
RF Exposure warning. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.
IC Warning
RSS-Gen 8.4 User manual notice
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions:
1. This device may not cause interference. 2. This device must accept any interference, including interference that may cause undesired
operation of the device.
Confidential. Sybersense IoT Co., Ltd
5
CNR-Gen 8.4 Avis inséré dans le manuel d’utilisation
L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d’Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes :
1. L’appareil ne doit pas produire de brouillage; 2. L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
susceptible d’en compromettre le fonctionnement.
RF Exposure warning.
This equipment complies with RSS-102 radiation exposure limits set forth for an uncontrolled environment. L’appareil est conforme aux limites d’exposition aux rayonnements du CNR-102 qui sont prescrites pour les environnements non contrôlés.
Confidential. Sybersense IoT Co., Ltd
6