simaluba SL09 Biodegradable Grease Instruction Manual
Define installation type, lubricant, lubricator size, dispensing time, and accessories
- Direct installation

- Indirect installation

- simalube lubricators can be installed in all positions, even underwater.

- Use “Calculation Pro” to choose correct lubricant, dispensing time, and lubricator size.
(“Calculation Pro” is available at www.simatec.com, in the App Store, and in the Android Market.)

Prepare lubrication point
- Clean lubrication point

- Remove connector nipple

- Screw in reducing nipple
(if necessary, seal lubrication point)
- Lubricate the grease lines with a grease gun
(fill tubes completely)
Install and activate simalube
- Cut off plug from lubricator or remove black plug

- Activate dispensing time with 3 mm Allen key

- Write in activation date

- Screw in lubricator

- Regularly check simalube

Dispose of simalube correctly
- Either refill or dispose of empty lubricators

- a) Remove cover disk
b) Remove gas generator with a socket wrench (SW21mm)
- Dispose of intact gas generator in battery recycling and empty housing in plastic recycling.
( Warning: dispose of leftover grease separately )
simatec ag
Stadthof 2
CH-3380 Wangen a. Aare
Tel.: +41 (0)32 636 50 00
Fax.: +41 (0)32 636 50 19
[email protected]