Honeywell Home VisionPRO Series with RedLINK Installation Guide - Manualsee

Honeywell Home VisionPRO Series with RedLINK Installation Guide

Honeywell Home VisionPRO Series with RedLINK Installation Guide
Honeywell Home VisionPRO Series with RedLIN

Wired Directly to Equipment 

Dual Powered – C Wire or Battery (C wire or Wire Saver required to use RedLINK accessories).

OR

RedLINK to Equipment Interface Module

2 Wires for Power or Battery Only (no wires)

OR

RedLINK to TrueZONE Wireless Adapter 

2 Wires for Power or Battery Only (no wires)

Reference to key features

features

Password is the date code.

Getting started

Follow these basic steps to install this
thermostat, link it with the wireless
accessories, and set installer options.

  1. Installing the thermostat
  2. Powering optional RedLINK accessories
  3. Performing initial setup
  4. Finding your password (Date Code)
    • To add or remove RedLINK accessories
    • To make changes to Installer Setup
    • To perform an Installer Test

Getting started

Installing the thermostat

NOTE: For best RedLINK performance, mount thermostats at least 2 feet apart.

Separate wallplate from thermostat.

wallplate

If your thermostat has a button along the top of the wallplate, press  button on top and pull to remove the wallplate as shown. Updated models do not have this button. On those models pull evenly along the sides and bottom of the thermostat to separate it from the wallplate.

Mount wallplate as shown.

Mount wallplate

Mount new wallplate using screws and anchors included with the thermostat. Drill 3/16-in holes for drywall. Drill 7/32-in holes for plaster.

Connect power.

  1. Insert supplied AA alkaline batteries for primary or backup power
    .Thermostat (back view)
    NOTE: When the thermostat is NOT used with the Equipment Interface Module or the TrueZONE Wireless Adapter, a C wire is required for RedLINK.
  2. For 24VAC primary power, connect common side of transformer to C terminal.
    HEAT PUMP

Wire the thermostat. Is the thermostat wired directly to the equipment

Wire the thermostat

  • If the thermostat is wired directly to the equipment: a Refer to the table and wiring diagrams on the next page. b Turn on 24VAC NOW. 24VAC (C wire) is required to connect RedLINK accessories.
  • If the thermostat is used with an Equipment Interface Module or TrueZONE Wireless Adapter, power the thermostat using Rc and C terminals or with batteries

    NOTE: The relay outputs and inputs on the thermostat do not function when used with an Equipment Interface Module or TrueZONE Wireless Adapter.

With thermostat removed from sub-base, insert the coin cell battery.

cell battery

NOTE: On some models the coin cell battery compartment slides out from the left side of the thermostat when viewing it from the back (not pictured).

Mount thermostat on wallplate.

NOTE: If your thermostat has hinges at the bottom of the wallplate as shown, insert the thermostat into the hinges, then push the top toward the wall until it snaps together. Updated models do not have hinges. On those models push evenly along the sides and bottom of the thermostat to connect it to the wallplate.

Terminal Designations

Terminal
C
Conventional S stem                                     Heat Pump

Description                                       Terminal Description

Common wire from secondary side of cooling transformer (if 2 transformers).CCommon wire from secondary side of cooling transformer.
Rc*Cooling power.RcCooling power.
R*Heating power.RHeating power.
WHeat Stage 1                                    0/BChangeover valve for heat pumps. Backup Heat/Emergency Heat
W2          Heat Stage 2                             AUX-E
YCompressor Stage 1YCompressor Stage 1
Y2Compressor Stage 2Y2Compressor Stage 2
GFan RelayGFan Relay
AConnect to Economizer Module or Lighting Panel (TOD).VAConnect to Compressor Monitor, Zone Panel, Economizer Module or Lighting Panel (TOD).
U1 / UlRelay for humidification, dehumidification ventilation, or a stage of heating/cooling.Ul / UlRelay for humidification, dehumidification ventilation, or a stage of heating/cooling.
51 / S1discharge a wired indoor, outdoor or discharge sensor.Si / Sidischarge a wired indoor, outdoor or discharge sensor.
K**Connect to K on C-wire adaptor.K**Connect to K on C-wire adaptor.

Remove factory installed jumper for two transformer systems.

The THP9045A1098 C-wire adaptor is used on heat/cool systems when you only have four wires at the thermostat and you would like the thermostat to be powered with a common wire. Use the  Kterminal in place of the Y and G terminals on conventional or heat pump systems to provide control of the fan and the compressor through a single wire—the unused wire then becomes your common wire. See THP9045 instructions for more information.

POWERED HUMIDIFIER, DEHUMIDIFIER OR VENTILATOR
VENTILATOR

DEHUMIDIFICATION WITH LOW SPEED FAN

Speed fan

Wire the thermostat U1 terminal to the low speed fan for dehumidification control at the equipment as shown. The relay can be set to normally open or normally closed in the installer setup.

  •   Normally open, dry contacts
  • Normally closed, dry contacts

NON-POWERED HUMIDIFIER, DEHUMIDIFIER OR VENTILATOR

VENTILATOR

CONNECTING A HEAT OR COOL STAGE TO U1

VENTILATOR

  1. U1 terminals are normally open dry contacts when set up for a stage of heating or cooling.
  2. You must install a field jumper if the stage of heating or cooling is powered by system transformer. Do NOT install a field jumper if the stage of heating has its own transformer. 1

Powering optional RedLINK accessories

accessories

Install batteries in RedLINK accessories

  • Portable Comfort Control
  • Wireless Outdoor Sensor*
  • Wireless Indoor Sensor*
  • Wireless Entry/Exit Remote*
  • Wireless Vent and Filter BoostRemote*
    • Requires setup. See Installer Setup options in Step 3.4.

Connect gateway to internet and connect to power. 

  • Connect RedLINK Internet Gateway to router or modem with Ethernet cable (RJ45).
  • Connect gateway’s power cord to an electrical outlet that is not controlled by a wall switch.

NOTE: If the thermostat is wired directly to the equipment, 24VAC (C wire) is required to connect RedLINK accessories. Turn on 24VAC before performing initial setup in Step 3.

Performing initial setup

Initial setup options define the type of system you are installing:

  • Residential or commercial
  • Non-zoned or zoned
  • Used with or without an Equipment Interface Module (THM5421)
  • Used with or without the TrueZONE Wireless Adapter (THM4000)

Follow prompts on the screen to select the appropriate options.

select the appropriate options
NOTE: If you are connecting the thermostat to the TrueZONE Wireless Adapter (THM4000), refer to the TrueZONE instructions to link the thermostat and RedLINK accessories. Then go to Step 3.4.

When you see the prompt Connect RedLINK Accessories? Touch No or Yes.

  • If you select No, continue to Step 3.4.
  • If you select Yes, you will be prompted to Press Connect on New Accessories. Continue to Step 3.3.

Connect each RedLINK accessory.

NOTE: Accessories must be at least 2 feet away from the thermostat during the linking process.

While the Press Connect message is displayed (listening mode), press and quickly release the CONNECT button on each new RedLINK accessory

Listening mode

After a short delay (up to 15 seconds), check thermostat to confirm the connection of each RedLINK accessory. Touch s or t to review the list.

Touch Done at the thermostat after all new RedLINK accessories are connected.

Finish the initial setup.

Finish the setup by selecting the desired options. Touch Done after you select the last option you want to change.

The thermostat now displays its Home screen and the thermostat setup is complete.

Finding your password (Date Code)

  • To add or remove RedLINK accessories
  • To make changes to Installer Setup
  • To perform an Installer Test

Finding your password

Finding your password

  1. Touch Menu.
  2. Select Dealer Information
  3. Scroll down to see the Date Code.

Linking RedLINK accessories to the thermostat

  1. Touch Menu.

  2. Select Installer Options.
  3. Enter password (date code) and touch Done.
  4. Select Wireless Manager
  5. Select Add Device. The screen displays “Press Connect on New Accessories.” The thermostat is now in listening mode.
    Select Add Device
    NOTE: Accessories must be at least 2 feet away from the thermostat during the linking process.
    Press and quickly release the CONNECT button on each new RedLINK accessory

    After a short delay (up to 15 seconds), check thermostat to confirm the connection of each RedLINK accessory. Touch s or t to review the list.

    NOTE: Thermostat displays a countdown timer while in the listening mode. If it detects no activity for 15 minutes, it exits listening mode.

Making changes to Installer Setup and performing an Installer Test

NOTE: Use a microSD card to save set up time. See next page.

Making changes to Installer Setup and performing an Installer Test
  1. Touch Menu. 
  2. Select Installer Options.
  3. Enter password (date code) and touch Done.
  4. Select Installer Setup or Installer Test

Using a microSD card for setup, data logs and software upgrades

Use a microSD (secure digital) card to save setup time by loading Installer Setup
settings, Dealer Information, Holiday Schedules, and Custom Reminders to multiple thermostats. For troubleshooting help, you can save the thermostat Data Logs (Alerts Log and Interaction Log) to a microSD card – then view them on your computer. Also use the microSD card to upgrade the thermostat software.

Loading Dealer Information and New Thermostat Software: 

USB  adapter

  1. Visit http://thermostatsetup.honeywell.com to enter your dealer information or load new thermostat software.
  2. Connect a microSD USB Adapter to your computer to download the file(s).
  3. After the file(s) are downloaded, remove the microSD card from the adapter and insert into thermostat.

To use the microSD card in the thermostat:

  1. Slide card into the bottom of thermostat.
  2. Select the item to load or save.
  3. Follow the prompts on the screen.
    • To add information from the card to the thermostat, select Load from SD Card.
    • To put thermostat information on the card, select Save to SD Card.
  4. When you are finished, touch Done, then Home, and remove the microSD card.

To replace a thermostat

When you replace a thermostat, you must reset the RedLINK accessories before connecting them to the new thermostat. Follow the instructions below:

At the Portable Comfort Control: 

Press and hold the blank space (or arrow) in the lower right hand corner of the screen until the display changes (hold for about 4 seconds). Press REMOVE, then YES to disconnect from the old thermostats. To reconnect the thermostat, go to Step 3.2.

At the Indoor Sensor, RedLINK Internet Gateway, Entry/Exit Remote, Vent-Filter Boost Remote or TrueSTEAM Wireless Adapter:

Press and hold the CONNECT button on the accessory until the status light glows amber (hold for about 10 seconds). To reconnect the thermostat, go to Step 3.2.

At the Equipment Interface Module (EIM): 

Press and hold the CONNECT button on the EIM until the CONNECTED LED glows amber (hold for about 10 seconds). Follow the prompts on the screen to connect the new thermostat to the EIM.

Specifications and replacement parts

Operating Ambient Temperature

Thermostat: 32 to 120° F (0 to 48.9° C)
Portable Comfort Control: 32 to 120° F (0 to 48.9° C)
Wireless Outdoor Sensor: -40 to 140° F (-40 to 60° C)
Wireless Indoor Sensor: 0 to 120° F (-17.8 to 48.9° C)
-For Optimal Battery Life: 35 to 114° F (1.7 to 45.6° C)
Equipment Interface Module: -40 to 165° F (-40 to 73.9° C)
Return Air Sensor: 0 to 200° F (-17.8 to 93.3° C)
Discharge Air Sensor: 0 to 200° F (-17.8 to 93.3° C)
RedLINK Internet Gateway: 32 to 120° F (0 to 48.9° C)

Operating Relative Humidity 

Thermostat: 5% to 90% (non-condensing)
Portable Comfort Control: 5% to 90% (non-condensing)
Wireless Outdoor Sensor: 0% to 100% (condensing)
Wireless Indoor Sensor: 5% to 90% (non-condensing)
Equipment Interface Module: 5% to 95% (non-condensing)
RedLINK Internet Gateway: 5% to 95% (non-condensing)

Physical Dimensions (height, width, depth)

Thermostat: 4-15/16 x 4-5/8 x 1-1/8 inches (126 mm x 118 mm x 29 mm)
Equipment Interface Module: 9-5/16 x 4-13/16 x 1-19/32 inches (91 x 147 x 42 mm)
Wireless Outdoor Sensor: 5 x 3-1/2 x 1-11/16 inches (127 x 89 x 43 mm)
Wireless Indoor Sensor: 2-7/8 x 1-7/8 x 15/16 inches (74 x 48 x 24 mm)
Portable Comfort Control: 6-1/4 x 3-1/8 x 1-5/8 inches (158 x 80 x 38 mm)
RedLINK Internet Gateway: 3-7/8 x 3-9/16 x 1-1/8 (99 x 91 x 29 mm)

RedLINK Communication

Frequency: 900 Mhz frequency range
Re-Sync Time: RedLINK devices re-establish communication within 6 minutes after AC power resumes.

Electrical ratings

TerminalVoltage (50/60 Hz)            Max. Current Rating
W – 0818 to 30 VAC and 750 mVDC1.00A
Y (cooling)18 to 30 VAC1.00A
G (fan)18 to 30 VAC0.50A
W2 – Aux (heating)18 to 30 VAC0.60A
Y2 (cooling)18 to 30 VAC0.60A
A-VA (output)18 to 30 VAC1.00A
U1/U130VAC ma0.50A

Accessories and replacement parts

Accessories / Replacement Parts                                                                      Part Number
Equipment Interface ModuleYTHM5421R1010, THM5421R1021
Wireless Adapter for TrueZone, TrueSteam, or extend wireless range of El MTH M4000R1000
RedLINK Internet Gateway                                                                                                                THM6000R7001
Wireless Entry/Exit Remote                                                                                                              REM1000R1003
Wireless Vent and Filter Boost Remote                                                                                           HVC2OA1000
Portable Comfort Control                                                                                                                   REM5000R1001
Wireless Outdoor Sensor                                                                                                                  C7089R1013
Wireless Indoor Sensor                                                                                                                     C7189R1004
Wired Outdoor Sensor 10k ohm NTCC70139U1006
Wired Wall-mount Indoor Sensor 10k ohm NTCC7189U1005
Wired Flush-mount Indoor Sensor 20k ohm NTCC7772A1004, C7772A1012
Wired Wall-mount Indoor Sensor 20k ohm NTCTR21
Wired Watl-mount Indoor Sensor 10k ohm NTCTR21-A
Supply or Return Air Sensor 10k ohm NTCC7735A1000
Supply or Return Air Sensor 20k ohm NTCC7041
Supply or Return Air Sensor 20k ohm NTCC7770A1006
Cover Plate (covers marks left by old thermostats)THP2400A1019
C-wire adaptorTHP9045A1098
Model NumberingTH8321TH8320TH8110
Stages3H/2C HP
2H/2C
CONV
3H/2C HP
2H/2C
CONV
1H/1C HP
1H/1C
CONV
Residential or Commercial
Dual Powered C Wire or Battery
Onboard Humidity Sensor  
Number of IAQ Relays100
Number of Sensor Inputs111
Economizer / TOD Output 
Works with Optional Equipment Interface Module*
Works with Optional TrueZONE Wireless Adapter*

The relay outputs and inputs on the thermostat do not function when used with an Equipment Interface  Module or the TrueZONE Wireless Adapter.

If the thermostat has been setup WITHOUT an Equipment Interface Module or the True ZONE Wireless Adapter and you would like to add one, you must reset the thermostat back to factory defaults. Press MENU > Installer Options > scroll down to select Reset to Defaults.

  • DISCONNECT POWER BEFORE INSTALLATION. Can cause electrical shock or equipment damage.
  • This thermostat contains a Lithium battery which may contain Perchlorate material. Perchlorate Material—special handling may apply. See www.dtsc.ca.gov/hazardouswaste/ perchlorate
  • MERCURY NOTICE: If this product is replacing a control that contains mercury in a sealed tube, do not place the old control in the trash. Contact the Thermostat Recycling Corporation at www.thermostat-recycle.org or 800-238-8192 for information on how and where to properly and safely dispose of your old thermostat.
  • Must be installed by a trained, experience technician. Read these instructions carefully. Failure to follow these instructions can damage the product or cause a hazardous condition.

Need Help?

For assistance please visit
http://customer.resideo.com,
or call toll-free: 1-855-733-5465

Scan for more information
scan

 

Documents / Resources

Honeywell Home VisionPRO Series with RedLINK [pdf] Installation Guide
VisionPRO Series with RedLINK
Honeywell Home VisionPRO Series with RedLINK [pdf] Instructions
TH8110R1008, TH8320R1003, TH8321R1001, VisionPRO Series with RedLINK