Rheem Proe50-t2-rh95 Professional Classic Standard Electric Water Heater User Manual

Rheem Proe50-t2-rh95 Professional Classic Standard Electric Water Heater User Manual

Rheem-PROE50-T2-RH95-Professional-Classic-Standard-Electric-Water-Heater-logo

Rheem PROE50-T2-RH95 Professional Classic Standard Electric Water Heater

Rheem-PROE50-T2-RH95-Professional-Classic-Standard-Electric-Water-Heater-product-image

Professional Classic® electric water heaters are engineered for longer life – registered heating elements and premium grade anode rod

Efficiency

  • 90 – .93 UEF
  • Isolated tank design reduces conductive heat loss
  • Registered stainless steel upper and lower heating elements to prolong anode rod and tank life
    Rheem-PROE50-T2-RH95-Professional-Classic-Standard-Electric-Water-Heater-01

Performance

  • FHR: 45 – 67 gallons, based on gallon capacity
  • Recovery: 21 GPH at a 90° F rise†

System Sentinel
(Available on selected models)

  •  Exclusive diagnostic system with glowing LEDs that verify heating element operation. LEDs pin point the exact location of functioning or non-functioning heating elements

Longer Life

  •  Premium grade anode rod provides long-lasting tank protection

Features

  • Electric junction box located above heating elements for easy installation
  • Over-temperature protector cuts off power in excess temperature situations
  • Automatic thermostat keeps water at desired temperature

Plus…

  • Rheemglas® tank lining resistscorrosion and prolongs tank life
  • EverKleen® self cleaning device fights harmful sediment build-up with a high- velocity spiraling water stream –helps operating efficiency by saving energy, money and improving tank life
    Rheem-PROE50-T2-RH95-Professional-Classic-Standard-Electric-Water-Heater-02
  • Enhanced-flow brass drain valve
  • Temperature and pressure relief valve included
  • Models are compliant to HUD Standards for manufactured housing and modular construction
  • Low lead compliant

Warranty

  • 6-Year limited tank and parts warranty*
  • With Protection Plus™ the 6-year limited tank warranty becomes 10-year

* See Residential Warranty Certificate for complete information
Units meet or exceed ANSI requirements and have been tested according to the AHRI Operations Manual and D.O.E. procedures. Units meet or exceed the energy efficiency requirements of NAECA, ASHRAE standard 90, ICC Code and all state energy efficiency performance criteria.

Professional Classic® Specifications

DESCRIPTIONFEATURESROUGHING IN DIMENSIONS (SHOWN IN INCHES)ENERGY INFO.
T Y P ENOMINAL GALLON CAPACITYRATED GALLON CAPACITYMODEL NUMBERFIRST HOUR RATING (GALLONS)RECOVERY IN G.P.H. 90° F RISETANK HEIGHT A 

HEIGHT TO WATER CONN. B

DIAMETER CAPPROX. SHIP WT. (LBS.)UNIFORM ENERGY FACTOR (UEF)
Tall3027PROE30 T2 RH95††462147-1/250-3/819920.92
Tall4036PROE40 T2 RH95††552160-3/463-5/819-1/41090.93
Tall5045PROE50 T2 RH95††632158-5/861-5/820-1/41210.93
Tall5555PROE55 T2 RH94††72215759-3/422-1/41280.92
Med.3027PROE30 M2 RH95††452137-1/240-1/220-1/4920.90
Med.4036PROE40 M2 RH95††552148-1/450-1/220-1/41060.93
Med.5045PROE50 M2 RH95††62214850-1/2231320.93
Short19.9PROE20 S2 RH2131-1/231-1/21762
Short2825PROE28 S2 RH9545213031-1/823950.92
Short3027PROE30 S2 RH95 B*4621303219-3/41100.92
Short3633PROE36 S2 RH95462131-1/23324-1/41180.92
Short3835PROE38 S2 RH95 B**512131-1/234231080.92
Short4743PROE47 S2 RH955421323426-1/41490.93

Uniform Energy Factor and rated gallon capacity based on Department of Energy (DOE) requirements.

System Sentinel optional. Add EC1 to the end of the model number. System Sentinel not available on single element models, available on dual element models only. System Sentinel not available in excess of 5 kW on 208 V models.

* Insulation blanket(s) required to achieve UEF value. Water heater dimensions prior to installing insulation blanket(s). Blanket(s) will be included with water heater. The blanket(s) add 2-1/2 inches to the tank height and 10 inches to tank diameter.
** Insulation blanket(s) required to achieve UEF value. Water heater dimensions prior to installing insulation blanket(s). Blanket(s) will be included with water heater. The blanket(s) add 2 inches to the tank height and 4 inches to tank diameter.

  • Heaters furnished with standard 240 volt AC, single phase non-simultaneous wiring, and 4500 watt upper and lower heating  elements.
  • If heating elements of different wattages than those shown are demanded by zone requirements, they must be specifically requested.
  • Single element models available on special order (6000W max.). Substitute “1” for “2” in model number.
  • Special Wiring Options – A limited number of special wiring options are available. Consult factory for price and availability.
  • All models equipped with heat traps.

Recovery calculations used are based on 4500 watt elements used in non-simultaneous operation.Rheem-PROE50-T2-RH95-Professional-Classic-Standard-Electric-Water-Heater-03