Roypow S2450 Floor Cleaning Machine Battery User Manual

Roypow S2450 Floor Cleaning Machine Battery User Manual

RoyPow LOGO

RoyPow S2450 Floor Cleaning Machine Battery

RoyPow S2450 Floor Cleaning Machine Battery

 

Use Your S2450

Recharge the S2450RoyPow S2450 Floor Cleaning Machine Battery 1
Charger: Not includedRoyPow S2450 Floor Cleaning Machine Battery 2

WARNING

  • Due to the transportation restrictions, the RoyPow battery will be charged to about 30% SOC before delivery. Recharge it fullv before the first time use.
  • To preserve battery lifespan, use and recharge at least once every 3 months!
  • The lithium battery charger is highly recommended, although the universal SLA battery charger is also applicable.

SPECIFICATIONSRoyPow S2450 Floor Cleaning Machine Battery 3RoyPow S2450 Floor Cleaning Machine Battery 4RoyPow S2450 Floor Cleaning Machine Battery 5RoyPow S2450 Floor Cleaning Machine Battery 6

ApplicationsRoyPow S2450 Floor Cleaning Machine Battery 7

WARNING

Suggest charging the RoyPow battery periodically to the regular battery storage voltage (12.8V-13.24V, 30 50% SOc) to avoid over-discharge.

Wiring Diagram ( Series & Parallel)

  • Series Connection (48V 50Ah)RoyPow S2450 Floor Cleaning Machine Battery 8
  • Parallel Connection (24V 100Ah)RoyPow S2450 Floor Cleaning Machine Battery 9
  • Series & Parallel Connection (48V 100Ah)RoyPow S2450 Floor Cleaning Machine Battery 10
  1. All RoyPow batteries must be separately recharged fully before being connected in series or parallel.
  2. If connected in both of series and parallel, make sure connect the RoyPow S2450 batteries in parallel first, then connect the parallel RoyPow S2450 batteries in series.
  3. For series connection, all batteries must be charged or discharged at the same time for proper functionality
  4. Do not connect more than two RoyPow S2450 in series.
  5. Do not recommend connecting more than two RoyPow 2450 batteries in parallel.
  6. If connected in both of series and parallel, recommend connecting the maximum two RoyPow S2450 batteries in series and two RoyPow S2450 batteries in parallel (Max 2S2P).
  7. Do not connect the RoyPow S2450 with the RoyPow batteries in different models or the batteries from other manufacturers.
  8. When below 0’C/32°F, self heating function of the RoyPow S2450 only works when being charged via the charger.

Attention

  • RoyPow S2450 Floor Cleaning Machine Battery 11Use certified lithium battery charger or SLA battery charger to recharge.
  • RoyPow S2450 Floor Cleaning Machine Battery 12Do not expose to liquids
  • Do not disassemble
  • RoyPow S2450 Floor Cleaning Machine Battery 14Avoid dropping
  • RoyPow S2450 Floor Cleaning Machine Battery 15Avoid extreme temperatures
  • RoyPow S2450 Floor Cleaning Machine Battery 16To maximize the life span of the battery cells,suggest using the RoyPow battery within 70% DOD,constant charge and discharge rate should not exceed 1C.

Documents / Resouces

Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.


Related Manuals