61059 Selectis Serenity Elite Low Air Loss Alternating Pressure Mattress System
Product Information
Tel: (888) 363-5563
Email: [email protected]
Website: www.emeraldsupply.net
SELECTIS ALTERNATING PRESSURE PUMP AND MATTRESS USER
MANUAL
Model 61059
Important Safeguards
- Product Functions
The Selec s Serenity Elite pump and mattress are intended to
reduce the incidence of pressure ulcers while optimizing patient
comfort. It also provides the following:
- Individual home care setting and long-term care
- Pain management as prescribed by a physician
Pump Functions
The functions of the Serenity Elite pump are described
below:

- Power Switch(1): The switch is at the right side of the pump.
Turn ON/OFF the power and press Power button on the panel, the pump
will start/stop operation.
Installation & Operating Instructions
- Place pump on horizontal surface or hang it by means of the
hook. - Open mattress on the bed. Secure it with end flaps or
straps. - Connect air feed tubes to air outlet on the mattress and pump,
ensuring that the tubes are not kinked or twisted. - Allow space for bed rails to drop freely.
- Turn on the power. After a beep sound, the pump will begin the
operation. The pump will enter static mode initially when the power
is turned on. The cycle will start after a few seconds.
Environment Requirements
Cleaning Guidelines
Maintenance
General
If you have any questions or need assistance, please contact
your local agent or dealer.
Technical Specifications
Pump
- Item: Serenity Elite
- Power supply: 120V/60Hz, 1A
- Air output: 8 liters/min.
- Pressure range: 20 mmHg – 55 mmHg
- Cycle: 10/15/20/25 min. Max firm mode
- Alarm: Low pressure/Power failure/Alternate failure
Alternate/Static/Seat inflate mode - Size: 31cm(L) x 12.5cm(W) x 21cm(H)
- Weight: 2.5 kg
Mattress
- Item: Seren Elite-61059
- Size: 80 (L) x 36 (W) x 8 (H)
- Top cover: Quilted bi-elastic cover with zipper
- Air cells: Nylon PVC (8 cell on cell construction with 5 upper
layer alternating and 3 lower layer static) - Base: Nylon / PVC 840D
- 20 air cells
- CPR valve for emergency procedures
- Transport function
- Quick connectors
- Pillow on 2 sides
Contact Information
Tel: (888) 363-5563
Email: [email protected]
Website: www.emeraldsupply.net
Tel: (888) 363-5563 Email:[email protected]
www.emeraldsupply.net
SELECTIS ALTERNATING PRESSURE PUMP AND MATTRESS USER MANUAL
Model 61059
Important Safeguards
1
Product Func ons
Intended Use The Selec s Serenity Elite pump and ma ress are intended to reduce the incidence of pressure ulcers while op mizing pa ent comfort. It also provides the following:
Individual home care se ng and long-term care Pain management as prescribed by a physician Pump The func ons of the Serenty Elite pump are described below. Please refer to the below figures.
9
56 78
Power Switch(1) The switch is at the right side of the pump. Turn ON/OFF the power and press Power buton on the panel, the pump will start/stop operaton.
· Press Cycle Time(2) · The cycle me is selectable from the panel. · The cycle me value can be either 10, 15, 20, or 25 minutes.
· Press Pressure Range(3) · 20mmHg~55mmHg is offered from the panel, providing op ns of pressure value by easy press.
· Alarm Mute (4) · The audible/visible alarm turns on a er 1 minute when low pressure, power failure or alternate failure. · To mute the audible alarm, press the Alarm Mute buton. The visible alarm indicator will flash l problem solved. · Re-press the Alarm Mute buton to reac ate the alarm.
· Alternate mode(5) · Press to set the air matress in alternate mode.
· Statc mode(6) · Press to set the air matress in statc mode.
· Max Firm(7) · Press to set the air matress in quick inflaaon mode, which facilitates nursing and caring.
· Seat Inflate (8) · Press to set the air matress in seat inflate+ alternate or seat inflate+ statc mode, pressure value will increase by 5mmHg, which facilitates sea g. · Under max firm mode, because the pressure is already set at the largest value, no more 5mmHg will be increased.
· Lock buton (9) · The panel will automa caly lock in 5 minutes without opera n. · Press the lock buton and hold for 3 seconds, to lock or unlock the panel.
Matress Elite
Installa on & Opera ng Instruc ons
Place pump on horizontal surface or hang it by means of the hook. Open ma ess on the bed. Secure it with end flaps or straps. Connect air feed tubes to air outlet on the ma ess and pump, ensuring that the tubes are no”t kinked”or twisted. Allow space for bed rails to drop freely. Turn on the power. A er a beep sound, the pump will begin the operaton. The pump will enter statc mode initally when the power is turned on. The cycle
me is set at the 1st LED (10 min.), and the pressure level is set at the 3rd LED (30±2mmHg). First it will inflate the ma ess to 10-15±2 mmHg and then enter alternate mode. During normal opera n, the pump will monitor pressure changes. If the pressure is below a user-defined pressure level, the pump will automa caly start to inflate the ma ess. The pump will stop when the user-defined pressure level is reached. The first infllaon of new ma ess: the alarm func n (visible and audible alarm) will actvate if matress is not inflated completely within 40 minutes. During pump is running, low pressure alarm will actvate within 1 minute a er air tubes are disconnected or air cells are broken. If there should be power failure, for example caused by power cord unplugged or power off when pump is working, the audible alarm will be actvated and power failure indicator will flash. When power is back, pump will automatcally start working. If the matress stops alternatng or alternate abnormally, the audible alarm will be actvated and alternate failure indicator will flash. For nursing and caring convenience, press the max firm bu on to automa caly inflate the ma esses to the maximum level (55mmHg) for about 20 minutes. The pressure will return to alternate mode a er 20 minutes.
4
Environment Requirements
· Operaton Temperature: 50~95 (10~35) · Storage Temperature: 5~122 (-15~50) · Operaton Humidity: 20%~80% non-condensing · Storage Humidity: 10%~90% non-condensing
Cleaning Guidelines
· Can be cleaned by disinfectant solu on · Do not immerse the pump in water · Do not heat or steam in autoclave · The matress and cover are aerated un l they are fully dry
Maintenance
General
· Check the power cord and plug to see if there are abrasions or excessive wear. · Check the ma ress cover for signs of wear or damage. Ensure the ma ress cover and tubes
are connected together correctly. · Plug in the pump unit and check the airflow from the hose connec on port. The airflow should
alternate between ports every half-cycle me. · Check the air hoses to see if there are any kinks or breaks. For replacement, please contact
your local agent or dealer. · Make sure the ma ress tube is well connected. · Check the pump unit and make sure both power indicators are off when the switch is turned
off.
Low pressure
Examine if there is any air leakage between the pump and the ma ress connec ons or from the air ma ress tubes: · Check connectors between the air ma ress and pump. If there is any disconnec on, please
reconnect it. · Check the CPR Valves. Ensure their outlets are sealed. · Check the air-connec ng tubes. Ensure each single cell is not broken. · Set the pressure at Max firm. Keep the tubes fully inflated and inspect for air leakage. · Check if there is any air leakage from cells. Ensure no leakage occurs. If any leakage occurs,
please contact your local agent or dealer.
5
Technical Specific
Pump
Matress
Item:
Serenity Elite
Power supply: 120V/60Hz,1A
Air output: 8 literm/ in.
Pressure range: 20 mmHg – 55 mmHg
Cycle 10/15/20/25 min. Max firm mode Alarm:Low pressure/Power failure/ Alternate failure Alternate/Statc /Seat inflate mode Size:31cm(L) x 12.5cm(W) x 21cm(H) Weight: 2.5 kg
Item:
Seren Elite- 61059
Size:80″ (L) x 36″ (W) x8″ (H)
Top cover: Quilted bi-elastc cover with
zipper
Air cells:Nylon PVC
(8″cell on cell constructon with 5″ upper layer alternatng and 3″ lower layer statc)
Base: Nylon / PVC 840D
20 air cells
CPR valve for emergency procedures
Transport functon Quick connectors Pillow on
6
2 s 2
Tel: (888) 363-5563 Email: [email protected]
www.emeraldsupply.net
7