Firman P06702 Recoil Start Gasoline Portable Generator User Manual

Firman P06702 Recoil Start Gasoline Portable Generator User Manual

FIRMAN logoP06702 Recoil Start Gasoline Portable Generator
User Manual

Troubleshooting

ProblemCauseCorrection
The engine is running, but no AC output is available.1. Circuit breaker is open.
2. Fault in the generator.
3. Poor connection or defective cord set
4. Connected device is bad.
1. Reset the circuit breaker.
2. Contact the authorized service facility.
3. Check and repair.
4. Connect another device that is in good condition.
Engine runs good at no-load but ‘bogs down”
when loads are connected.
1. Short circuit in a connected load.
2. Engine speed is too slow.
3. Shorted generator circuit.
4. Clogged or dirty fuel filter.
1. Disconnect shorted electrical load.
2. Contact the authorized service facility.
3. Contact the authorized service facility.
4. Clean or replace the fuel filter.
The engine will not start; starts and runs rough or shuts down when running.1. Fuel valve set to OFF (0) position.
2. Low oil level.
3. Dirty air cleaner.
4. Out of gasoline. S. Stale gasoline.
6. Spark plug wire not connected to spark plug.
7. Bad spark plug.
8. Water in gasoline.
9. Flooded.
10. Excessively rich fuel mixture.
11. Clogged or dirty fuel filter.
1. Turn the fuel valve to the “ON’ (I) position.
2. Fill the crankcase to the proper level or place the generator on a level surface.
3. Clean or replace the air cleaner.
4. Fill the fuel tank with gasoline.
5. Drain the fuel tank and carburetor; fill with fresh gasoline.
6. Connect a wire to the spark plug.
7. Replace the spark plug.
8. Drain the gas tank and carburetor, and fill them with fresh gasoline.
9. Wait 5 minutes and re-crank the engine.
10. Contact the authorized service facility.
11. Clean or replace the fuel filter.
The engine lacks power.1. Load is too high.
2. Dirty air filter.
3. Clogged or dirty fuel filter.
4. Clogged spark arrester.
1. Don’t Overload Generator
2. Replace the air filter.
3. Clean or replace the fuel filter.
4. Clean or replace the spark arrester.
Engine “hunts” or falters.1. Carburetor is running too rich or too lean.
2. Clogged or dirty fuel filter.
1. Contact the authorized service facility.
2. Clean or replace the fuel filter.
The engine shuts down when running.1. Out of gasoline.
2. Dirty air cleaner.
3. Low oil level.
1. Fill the fuel tank with gasoline.
2. Clean or replace the air cleaner.
3. Fill the crankcase to the proper level or place. generator on a level surface.
The engine shuts down and the yellow CO fault light blinks.1. CO system fault1. Contact the authorized FIRMAN service facility.

SPECIFICATIONS

ModelP06702
Starting Watts8375
Running Watts*6700
Rated AC Voltage120/240V
Rated Frequency60Hz
PhaseSingle
Voltage RegulatorAVR
Power Factor1
Alternator TypeBrushed
EngineFIRMAN
Engine TypeSingle Cylinder. 4-Stroke OHV Air Cooled
Displacement389cc
Low Oil ShutdownYes
Ignition SystemBreakless Ignition Type. Flywheel Magneto
Starting SystemRecoil
FuelUnleaded Automotive Gasoline
Capacity Fuel Tank8 U.S. Gallons (30L)
Lubricating Oil Capacity37.2 oz (1.1 L)
Carburetor TypeFloat
Air CleanerPolyurethane Type
P.T.O. Shaft RotationCounter Clockwise (Facing P.T.O.)
Oil TypeSee “Add Engine Oil” Section
AC Grounding SystemNeutral Bonded To Frame

*Generator certified in accordance with CSA (Canadian Standards Association) standard C22.2 No. 100-14, Motors and Generators.