Fanmaster Imf600 Axial Misting Fan Instruction Manual

IMF600 Axial Misting Fan

Product Information:

The AXIAL MISTING FAN is a powerful fan designed to provide
cooling and misting capabilities. It features a misting motor,
pump, and water tank for misting functionality. The fan is equipped
with an oscillation motor for wide-angle air distribution. It has a
safety grill, misting plate, water outlet, and water gathering
plate for efficient misting. The fan operates at a power of 800W
and has a speed of 910rpm. It can produce an air flow of 160m3/min
and air pressure of 90Pa. The oscillation angle is 90 degrees, and
the misting volume can reach up to 10L/h. The fan also has a noise
level of 70dB.

Product Usage Instructions:

  1. Before assembly, ensure that the fan is not plugged in and
    carefully remove all packaging materials.
  2. Check all components to make sure there are no shortages or
    damages during transportation.
  3. Assembling Tank Cart:
    • Refer to diagram 1. Loosen two M8 bolts and remove the
      oscillation device.
    • Refer to diagram 2. Assemble the left supporter and
      right supporter on the tank cart using M8 bolts.
  4. Assembling Oscillating Device And Handle:
    • Refer to diagram 3. Assemble the oscillating device on
      the top of the left and right supporters and secure it with M16
      bolts and M16 hand wheel.
    • Refer to diagram 4. Assemble the handle inside the
      left and right supporters using the M6 screw.
  5. Settling Water Tank:
    • Refer to diagram 5. Place the water tank on the tank
      cart.
  6. Assembling Misting Fan And Electric Box:
    • Refer to diagram 6. Place the misting fan on the
      oscillation connect panel and secure it with an M8 bolt.
    • Refer to diagram 7. Fix the electrical box behind the
      horizontal plate using M6 screws.
    • Connect the two-core male and female connectors of the water
      pump and the four-core male and female connectors of the
      oscillating device.
    • Lock the nut and connect the upper blue water pipe to the lower
      end of the regulating ball valve.

Please refer to the provided structure diagram for a visual
representation of the product components and their respective
numbers.

Cautions
1. When opening packing box, please take machine head out as per direction sign. 2. Don’t insert hands or any objects into the machine guards and misting plate. 3. Upward and downward angle of machine must be adjusted within stated angle range. 4. Don’t put the machine close to curtain and other easily sucked in objects 5. Don’t put the machine on uneven place. 6. Children,elders and weak people can’t stand in front of the machine for a long time. 7. Type Y attachment – Damaged supply cords to be replaced by the manufacturer,service agent or similarly qualified person to avoid hazard. 8. Please cut off the power and send the machine to qualified technician for checking if the running machine emit unusual noise,smoke or machine blade can not run after power supply. 9. Except maintenance scope, unprofessional person should not dissemble repair or rebuild the machine. 10. Take away non-humidity proof objects when starting the mist function in order to avoid causing rusty or damage to the objects. 11. The appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
Maintenance
1. In order to keep the machine durable, you should clean the machine timely. 2. Please cut off the power before cleaning and remove the front guard and blade.Clean the machine with soft cloth, ( please don’t use gasoline or other corrosive liquid ) please dry the guard and blade with dry cloth,then install the machine.( Attention:mist plate inside misting system can’t be dissembled ). 3. Please don’t let water flow into the motor and wet electric elements during cleaning, also don’t press / bend the blade and change the pitch angle of the blade. 4. In order to keep water clean in water tank,please wash the water tank,water-receiving plate at a proper time. 5. To ensure machine can oscillate smoothly,please add grease oil to the rotary part of oscillating mechanism every 6 months. 6. Please clean the machine and seal the whole machine with plastic bag before long time storage of the machine.

AXIAL MISTING FAN
INSTRUCTION MANUAL

Please read the instructions carefully before use.

/0%5)2

Feature And Application
1. Utilize CAD optimized design ,good and graceful looking. 2. Centrifugal misting system means no nozzles and filter water, with reasonable structure and simple maintenance. 3. Fan surface is epoxy resin coated, anti-rust and durable. The fan electrical components are designed to be waterproof. Safe to use, with tank cart, easy to move. 4. Air supplying, misting and oscillating functions are driven by different motors. Motors adopt high quality ball bearings, with advantages of stable, low temperature-rise, long service life, low noise, and strong overloading ability. 5. The misting function is controlled by an independent switch, with good misting effect and adjustable misting volume. 6. Fan is equipped with independent control oscillation device . Convenient and reliable for use. 7. Designed for cooling, dedusting and deodorizing in factories, residential areas, shopping malls , athletic fields, livestock farms, greenhouses, paper mills, tobacco factories and more.

Operating Instructions
1. Apply the fan complied to the voltage and frequency shown on the rating label. Do not use in corrosive environment. 2. When socket is used in power supply, the socket should meet the IEC335-1 standard. When power liner is from direct power supply, a polarity switch should be installed with contact gap not less than 3mm on the fixation wiring. 3. Oscillating angle adjustment: Loosen hand wheels on the fan left side and right side. Move it to the desired angle and tighten hand wheels. 4. Make sure two casters locked and tank is filled with certain amount of water before using the misting mode. 5. Filled with certain amount of water, then connect the power supply of the fan and press the fan button to run the fan motor. Press misting button to run misting motor and water pump. By pressing oscillating button, the fan will automatically oscillate. 6. Misting adjustment between “OFF” and “ON” when the fan runs with misting . 7. The fan can operate continually for 8 hours with the maximum misting volume when the fan runs with misting . Re-fill the tank to achieve the misting effect when it is short of water. 8. In the use of water tank cart, DO NOT force to push the tank cart before opening the bake of the caster. Close the bake of the caster when stopping the tank cart. DO NOT stop the tank cart at the slope to prevent sliding forward. 9.Clean the tank each time before use. Take out the water pump before clean . Pour out the water after clean. 10.Press the misting button to cut off the power supply between misting motor and water pump, and the fan can be used for blowing.

Wiring Diagram

Fan motor

Thermic fuse Communal winding(Brown) N

Primary winding(red) Secondary winding(Blue)

Capacitor

Earth wire(Yellow/Green)

Purple

Black

Fan button

Oscillation motor

Communal winding(black) Primary winding(red) Secondary winding(Yellow)

Thermic fuse

Communal winding(black) Primary winding(Brown) Secondary winding(Blue)

Black

Black

Capacitor

Brown

White

Oscillation button

Black

Black

Capacitor

N

Brown

White

Misting button

Misting motor

Pump

Brown

Blue

N

Earth wire(Yellow/Green) Brown Blue

L 240V~ N 50Hz

ParameteIrtem Model

Power W

IMF-600

800

Speed rpm
910

Air flow

Air pressure

m 3/min Pa

160

90

Noise dB
70

Oscillating angle

90

Misting volume (Max)
L/h
10

remark:we don’t notify you if above technology parameter change

/0%5)2

5

Assembly Instructions
Do not plug in the fan before assembly. Carefully remove all packaging materials, make sure there is no residual foam left in any of the components. Carefully check all components, make sure there is neither shortage nor damage during transportation.

1. Assembling Tank Cart a. Refer to diagram 1. Loosen two M8 bolts and take out oscillation device. b. Refer to diagram 2. Assemble left supporter and right supporter on tank cart with M8 bolts.

Loosen M8 bolts.
diagram 1

Lock M8 bolts.
diagram 2

2. Assembling Oscillating Device And Handle. a. Refer to diagram 3. Assemble the oscillating device on the top of the left and right supporters, and fix it with M16 bolts and M16 hand wheel. b. Refer to diagram 4. Assemble the handle inside the left and right supporters with the M6 screw.

Lock M16 bolts Lock M16 hand wheel
diagram 3

Lock M6 screws
diagram 4

3. Settling Water Tank Refer to diagram 5. Place the water tank on tank cart.

diagram 5

Settling the water tank

4. Assembling Misting fan And

Electric Box

a. Refer to diagram 6.Place misting

fan on the oscillation connect panel

and lock by M8 bolt.

b. Refer to diagram 7.Fix the

electrical box behind the

lock M8 bolts

horizontal plate with M6 screws.

Connect the two-core male

and female connectors of water

pump and the four-core male

and female connectors of

oscillating device. Lock the

nut, and connect the upper blue

water pipe to the lower end of

the regulating ball valve.

diagram 6

fix M6 screws

connect blue water pipe

Connect and lock the male and female connectors

diagram 7

5. Misting Testing a. Fill the water tank with appropriate clean water and lid the tank cover and lock casters. b. Turn the misting ball valve from ON to OFF. Start the fan by pressing fan switch and check if fan motor and fan blade run normally. c. Press the misting button to start misting motor and water pump and check if the misting motor, misting plate and water pump run normally. d. Turn the misting ball valve from OFF to ON to check misting condition . e. Press the oscillation button to to check if the fan head oscillates smoothly.

misting volume valve misting button
fan button oscillation button

/0%5)2

Product Dimension

Structure Diagram
1 2 3456 7

9 10 11 12 13

8

20 21

23

22

24

25

15

14

19 18 17

16

26

28

27

1. Safety grill 2. Misting plate 3. Water outlet 4. Water gathering plate 5. Supporter of water gathering plate 6. Misting motor 7. Front grill 8. Water collection plate 9. Drum 10. Motor supporter 11. Fan motor 12. Blade 13. Rear grill 14. Pushing Handle

15. Left fan supporter 16. Right fan supporter 17. Electric box 18. M16 Hand wheel 19. horizontal plate 20. Extension pipe 21. Oscillation connect panel 22. Oscillation device 23. Water tank cover 24. Water tank 25. Front caster 26. Tank cart 27. Rear caster 28. Water pump

Documents / Resouces

Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.


Related Manuals