i6-5B-40 Vannus Ceiling Fan
Product Information
Model: i6-5B/40 i6-5B/56
Product: Ceiling Fan
Version: 2022 V1
Safety Precautions
- Installation and maintenance work should only be performed by
qualified persons familiar with local codes and regulations. - All field wiring must comply with national wiring
regulations. - Ensure that the rated voltage of the unit matches the voltage
stated on the nameplate before starting any wiring work. - The appliance must be connected to the electricity supply
through a double pole switch with a contact separation of at least
3mm in all poles. - The unit must be grounded to prevent hazards due to insulation
failure. - Tighten the blades firmly to prevent detachment during
operation, which can cause injuries and property damage. - This appliance is not intended for use by persons with reduced
physical, sensory, or mental capabilities, unless supervised or
instructed by a responsible person. - Children should be supervised to prevent them from playing with
the appliance. - Always switch off the power supply before installing or
servicing the unit, and ensure that the blades are fully static
before performing any maintenance work. - Stop using the ceiling fan and contact the manufacturer or
qualified persons if any abnormality or failure occurs, or if
unusual oscillating movement is observed.
Installation Instructions
- The fixing means for attachment to the ceiling, such as hooks
or other devices, should have sufficient strength to withstand four
times the weight of the ceiling fan. - The suspension system should be installed by the manufacturer,
its service agent, or suitably qualified persons. - Install the fan so that the blades are more than 2.5m above the
floor. - The safety cord should not be longer than the earthing
conductor. The fan’s earthing terminal should effectively earth the
body of the fan assembly in case of suspension system failure. - Ensure that the unit’s panel is closed securely after service
or installation to prevent noisy operation.
INSTRUCTION MANUAL
Version: 2022 V1
MODEL
i6-5B/40 i6-5B/56
CEILING FAN
Table of Contents
Item 1. Safety Precaution 2. Parts & Accessories 3. Installation Instruction 4. Power Supply Connection 5. Circuit Diagram 6. Transmitter Learning Process 7. Transmitter Function & Assembly 8. Maintenance 9. Technical Specifications 10. Customer Service Centre
Page No. 1 – 2 3 4 – 7 8 9 10 11 12 12 – 13 13
Safety Precaution
Warning
Installation and maintenance work shall only be performed by qualified persons, familiar with local code and regulation, and experienced with this type of appliance.
All field wiring must be installed in accordance with the national wiring regulation.
Ensure that the rated voltage of the unit corresponds to that of the name plate before commencing wiring work according to the wiring diagram.
The appliance must be permanently connected to the electricity supply through a double pole switch having a contact separation of at least 3mm in all poles.
The unit must be GROUNDED to prevent possible hazard due to insulation failure. The earth wire is approximately 60mm longer than safety wire. This is to ensure at the event whereby the suspension system fails, the (L) and (N) wire will break leaving the fan remain earthed to prevent electrocution.
Tighten the blade firmly using a screw driver. Blades that are detached from the unit during operation will cause serious injuries and property damages.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliances.
Confirm that the power supply has been switched OFF before installing or servicing the unit. Ensure that the blade is fully static before doing any maintenance work.
Safety Precaution
STOP using the ceiling fan when any abnormality or failure occurs. If unusual oscillating movement is observed, immediately stop using the ceiling fan and contact the manufacturer, its service agent or suitably qualified persons.
CAUTION
Please take note of the following important points when installing.
The fixing means for attachment to the ceiling such as hooks or other devices shall be fixed with a sufficient strength to withstand 4 times the weight of the ceiling fan.
The mounting of the suspension system shall be performed by the manufacturer, its service agent or suitably qualified persons.
The fan is to be installed so that the blades are more than 2.5m above the floor.
Safety cord should not be longer than the earthing conductor. Should failure of the suspension system occur, the supporting of the fan must not rely on the earthing conductor. The earthing terminal in the fan assembly should be such that should any part of the suspension system fall off, the body of the fan assembly shall effectively earthed.
Ensure that the unit’s panel is closed after service or installation. Unsecured panels will cause the unit to operate noisily.
Sharp edges and coil surfaces are potential locations which may cause injury hazards. Avoid from being in contact with these places.
Before turning off the power supply set the remote controller’s ON/OFF switch to the “OFF” position. If this is not done, the unit’s fans will start turning automatically when power resumes, posing a hazard to service personnel or the user.
Do not operate any heating apparatus too close to the ceiling fan unit or use in room where mineral oil, oil vapour or oil steam exist, this may cause plastic part to melt or deform as a result of excessive heat or chemical reaction.
Ensure the colour of wires of the outdoor unit and the terminal markings are same to the indoors respectively.
Don’t use joined and twisted wires for incoming power supply.
Do not place any object in the path of the blades. Avoid raising objects or your arms near the ceiling fan.
The fan suspension system and blade screw tightening shall be examined yearly.
Replacement of parts of the safety suspension system device shall be performed by the manufacturer, its service agent or suitably qualified persons.
Torque value for screw/bolts for securing primary suspension system for motor is 2Nm.
2
Parts & Accessories
Blade x 5
Motor Assembly
Receiver
Downrod Rubber Pulley Assembly
Canopy & Coupling Cover
AAA AAA
AAA Battery x 2
Blade Screw & Washer x 11
Transmitter & Holder
Wall Screw x 2
3
Installation Instruction
IMPORTANT : DO NOT CONNECT THIS REMOTE CONTROL CEILING FAN TO DIMMER SWITCH OR REGULATOR.
Step 1 a. Route all the wire form the motor through the downrod. Fix the downrod to
the coupling with bolt, washer, nut and tighten tehm firmly then insert the clevis pin. b. Assemble the coupling cover and the canopy through the downrod.
a. Motor Wire (Red, Grey & Pink)
Safety Wire Green/Yellow (E)
Washer & Nut Clevis Pin
b. Motor Wire (Red, Grey & Pink)
Safety Wire
Green/ Yellow (E)
Clamp the downrod with the 2 screws on the coupling to prevent shaking during operation.
Step 2 – Remove the Bolt, Clevis, Nut, Washer and Rubber Pulley from the Downrod. Place the Rubber Pulley onto the ceiling hook and fix back the Bolt, Clevis, Nut and Washer.
IMPORTANT : Clevis Pin MUST be insert to prevent nut from loosening.
Rubber Pulley
Bolt
Washer Nut
Clevis Pin
4
Installation Instruction
Step 3 – Remove the Safety Wire screw and spring washer from the Downrod.
Step 4 – Tie the Safety Wire across the hook as shown.
In the case of “J” Hook is being used.
5
Installation Instruction
Step 5 – Firmly screw the Safety Wire with spring washer onto the Downrod.
Step 6 – Connect the Connectors from Fan and Receiver. Connect the wires from the receiver to House’s Supply Wire. Connect Earth Wire to House Supply Earth Terminal.
Brown (L) Blue (N)
Green/Yellow (E)
House Supply Wires
Pink Pink Grey Grey Red Red
N
L
Brown (L) Blue (N) Green/Yellow (E)
Installation Instruction
Step 7 – Install the Blades on Motor with Blade Screw. Install the Switch Housing by twisting in. IMPORTANT : Assemble the Fan Blades only after the ceiling fan is mounted on the hook.
Blade Screw
Blade
Below shows a complete installation diagram.
6
7
Power Supply Connection
IMPORTANT : DO NOT CONNECT THIS REMOTE CONTROL CEILING FAN TO DIMMER SWITCH OR REGULATOR.
Regulator
Dimmer Switch
Double Pole Switch
Single Pole Switch
Circuit Diagram
DC Motor
Earth (Green/Yellow) Red Grey Pink
Neutral (Blue) Live (Brown) Earth (Green/Yellow)
Power Supply 220V-240V – 50Hz
W
ANT
V
U
Blue Brown Green/Yellow
MAIN PCB N L
E
220V-240V~ 50Hz
8
9
Transmitter Learning Process
The receiver & transmitter is pre-programmed in factory. If you wish to control 2 or more fans using 1 transmitter, the below steps are required. DO NOT PRESS ANY OTHER BUTTON DURING THIS PROCESS Step 1 a) Insert the 2 pcs of batteries (provided) into transmitter. b) Turn on the power supply (wall switch) to the fan. c) Within 10 sec, press and hold the “1” and “2” button for 3 sec. Once the receiver has
detected the frequency, transmitter will “Beep Beep” twice. Programming process is completed and fan is ready to use. If the fan is not responding to the transmitter, repeat Step 1b.
Press and hold for 3 sec
Transmitter Function
1 – 8 – Fan speed control – Natural wind, creating gentle seabreeze effect – Forward/Reverse, turn anti-clockwise or clockwise rotation. – Stop the fan
1H – Fan turn on after 1hr 3H – Fan turn on after 3hr 6H – Fan turn on after 6hr
Mount the remote control holder on the wall with the screws provided.
The transmitter & receiver is incorporated with last memory function. This function stores your last setting in memory and the next time you turn on the fan, fan will operate as the last setting.
Function of Forward & Reverse
Fan must be turned on and rotating.
Press Forward/Reverse button and fan will slow down and then change direction (approx. 15 sec). When the fan is slowing down to change direction, the Fan Speed function is disabled until direction has been changed.
Forward Fan rotates anti-clockwise blowing the air downwards creating the wind chill effect. Suitable for hot weather condition.
Reverse Fan rotates clockwise drawing the air towards the ceiling circulating the warm air downwards. This function works best at low speed. Suitable for air-conditioned condition.
10
11
Maintenance
Due to the fan’s natural movement, connections may get loose after period of usage. To ensure a proper and safety usage, it is highly recommended to inspect and tighten all connections every 6 months.
Cleaning Cleaning your fan periodically will prolong its new appearance. Basic cleaning procedures are as follows : 1. Use only water and mild soap. Do not use solvents, corrosive or acidic solution. 2. Damp the cloth lightly. Use only soft or lint-free cloth to clean the fan. Rough fabric will
scratch the surface. 3. Do not bent the blades while cleaning. At the event where blades are bent or damage,
order new set of blades from service center or dealer shop. 4. There is no need to oil the fan.
Technical Specifications
Model No. of Blades Fan Width Motor R.P.M Voltage Motor Wattage Nett Weight
i6-5B/56 5
1420mm (56″) 110 – 230
220V-240V~ 50Hz 5W – 38W 6kg
i6-5B/40 5
1015mm (40″) 110 – 260
220V-240V~ 50Hz 5W – 30W 5.6kg
12
More than 2.5m (8′ 2″) 320mm (12.6″) 380mm (15″)
Technical Specifications
More than 1m
i6-5B/40 : 1015mm (40″) i6-5B/56 : 1420mm (56″)
Customer Service Centre
If you need any technical assistance or faulty report, please contact our customer service centre at :
Alpha Home Appliances Sdn. Bhd. (390258-H)
Head Office : 6, Jalan Sungai Kayu 32/37, Berjaya Park, Sect 32, 40460 Shah Alam,
Selangor.
Tel
: 03-5740 6666
Fax : 03-5740 8220
Website : www.alphamalaysia.com Email : [email protected]
Johor Tel
: 71, Jalan Molek 3/10, Taman Molek, 81100 Johor Bahru.
: 07-353 4833 / 4933
Fax : 07-355 4233
Melaka Tel
: 19, 19-1 & 19-2, Jalan KSB 11, Taman Kota Syahbandar, 75200 Melaka.
: 06-292 6292 / 6293
Fax : 06-292 6296
Perak Tel
: 11, Laluan Tasek Timur 5, 31400 Ipoh, Perak.
: 05-545 2282 / 547 2282
Fax : 05-547 6282
Penang Tel
: 28, Jalan Icon City, Icon City, 14000 Bukit Mertajam, Penang. : 04-506 2366 / 2066 / 2566 Fax : 04-506 2966
Pahang Tel
: A131, Jalan Dato Wong Ah Jang, Taman Liza, 25100 Kuantan, Pahang.
: 09-516 5226
Fax : 09-513 9226
13