Ge Lighting Cswonblbwf1nn/st1p 3-wire (no Neutral Required) Switch Compatibility Instructions

Ge Lighting Cswonblbwf1nn/st1p 3-wire (no Neutral Required) Switch Compatibility Instructions

GE Lighting logo3-Wire (No Neutral Required) Switch Compatibility & Wiring
ConfigurationsGE Lighting logo 1

Switch Model Numbers

  • CSWONBLBWF1NN/ST1P
  • CSWONBLPWF1NN/ST1P
  • CSWONBLTWF1NN/ST1P
  • CSWDMBLBWF1NN/ST1P
  • CSWDMOCBWF1NN/ST1P

Requirements

  • Ground wire is required (Wire is usually green, green with a yellow stripe, or copper)
  • Wi-Fi 802.11 b/g/n @ 2.4 GHZ is required
  • Minimum Load 15 Watts
  • If you are using less than 15 Watts, non-dimmable LED bulbs, or C by GE or Cync Smart Bulbs on the circuit, you will need to use the included Bulb Adaptor. Use the optional Fixture Adaptor (available separately) where the Bulb Adaptor will not fit. Contact Customer Support at 1-844302-2943 for details.

Compatibility

  • Rating 120V AC 60Hz
  • Neutral wire is not required (Wire is usually white or grey and is not required)
  • Works with halogen, incandescent, and LED bulbs, including Cync/C by GE Smart Bulbs
  • Not for use with ceiling fans
  • LED up to 1.25 amps (150 Watts)
  • Incandescent/halogen up to 5 amps (450 Watts)
Wiring ConfigurationCompatibleUser Experience
3-Way InstallYesTwo switches on the same circuit controlling the same light(s).  All switches on the circuit must be a Cync Smart Switch.
4-Way/Multi-Way InstallNoThree or more switches on the same circuit controlling the same light(s). Having more switches on the circuit requires more syphoned current from the load which will cause inconsistent functionality and a poor experience. Due to the instability of this setup, this install is not compatible.
California 3-WayYesSee wiring diagram below for details.
Dead End 3-WayYesSee wiring diagram below for details.
Knob and Tube WiringNoThis wiring setup is not compatible or supported due to the risk of lower grade copper, and the potential of deterioration/snapping of the wires.
Mixing different switch brands with Cync Smart Switches on the same circuit.NoAll switches on the same circuit must be a Cync Smart Switch. Our switches will not function properly if they are mixed with a basic on/off switch, or a non-Cync Smart Switch on the same circuit.
Mixing Cync Dimmers and Cync On/Off Switches on the same circuitNoMixing 3-Wire Dimmers and 3-Wire Switches on the same circuit is not compatible. They all need to be either all 3-Wire Dimmers or 3-Wire Switches.
Light Bulb/Fixture
Compatibility
CompatibleUser Experience
CFLYesFor dimmers, select non-dimmable load since CFL’s cannot dim.
Florescent Fixtures with
Electronic Ballasts
NoNot compatible due to high capacitance and high switching frequency within the ballast circuitry which may cause interference with our switches.
Magnetic BallastsNoNot compatible due to high capacitance in the circuit from starting circuitry that may cause interference with our switches.
LED DriversNoDue to the variety of types and different specifications of LED Drivers, we cannot
guaruntee compatibility with our switches.
FansNoOur 3-Wire Switches are not compatible for fan switches. If you have neutrals in your switch box, we recommend our Fan Speed Smart Switch.
Pool Lights and/or PumpsYes, butIf it is within our current switch rating (120V 60HZ 1/4HP motor) and protected with a GFCI.

Single Pole

GE Lighting CSWONBLBWF1NN ST1P 3 Wire No Neutral Required Switch - fig 1

3-Way

GE Lighting CSWONBLBWF1NN ST1P 3 Wire No Neutral Required Switch - fig 2

California 3-Way

GE Lighting CSWONBLBWF1NN ST1P 3 Wire No Neutral Required Switch - fig 3

Dead End 3-Way

GE Lighting CSWONBLBWF1NN ST1P 3 Wire No Neutral Required Switch - fig 4

3 Wire (No Neutral Required) Switch Compatibility and Wiring Configuration Guide

GE Lighting logo

Documents / Resouces

Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.


Related Manuals