GS-5210PLG 10-Port Gigabit Long Range PoE+ Web Smart Switch
Product Information
The GS-5210PLG is a 10-Port Gigabit Long Range PoE+ Web Smart
Switch with 1 Gigabit RJ45 and 1 SFP Ports.
I-1. Package Content
- GS-5210PLG
- Quick Installation Guide
- Power Cord
- Rack-Mount Kit
I-2. Hardware Overview

- LED (PoE/Alert, PWR)
- Gigabit PoE Port (1~8)
- Gigabit RJ45 Port (9)
- Reset
- AC Power Socket
- SFP Port (10)
I-3. LED Status
| Function | Color | Description |
|---|---|---|
| PWR | Green | Power on |
| PoE Alert | Green | Total PoE power consumed is OVER PoE power budget |
| Link/ACT (Port 1-9) | Green Amber | Link at 1000Mbps Sending or receiving data Port disconnected or link fail |
| SFP (Port 10) | Green | Link at 1000Mbps Sending or receiving data Port disconnected or link fail |
| PoE (Port 1-8) | Green | Feeding power to PoE devices PoE function is not active |
Installation
II-1. Physically Setup
Read the following below procedures in the correct order.
Incorrect installation may cause damage to the product.
- Desktop Placement: Place the switch on a flat
surface and install the four rubber feet (included) on the bottom
of the switch.
- Rack-mount the switch: You can mount the
switch in any standard size, 19-inch (about 48 cm) wide rack with 1
Rack Unit (1U) of space, which is 1.75 inches (4.45 cm) high. A
pair of extension brackets and screws are needed to adapt the
switch to the rack size. Align the mounting brackets with the
mounting holes on the switch’s side panels and secure the brackets
with the screws.
Secure the switch on the equipment rack.
II-2. Connection
- Power on: Connect the power cord to the switch
and the power outlet. The switch is powered by the 100-240VAC
50/60Hz external high-performance power supply. (Note: Make sure
the PWR LED is green.) - Uplink: Plug the standard Cat5e Ethernet cable
into the LAN port no. 9 or plug the SFP cable into the SFP slot and
connect it to the LAN server or core switch. (Note: Make sure that
the LED is green or amber.) - Connect devices: Plug the standard Cat5e
Ethernet cable into the LAN port and connect to any networking
device with an Ethernet port. (Note: Make sure that the LAN LED is
green or amber.) The hardware installation is complete!
GS-5210PLG
Quick Installation Guide
03-2022 / V1.0
Contents
I. Product Information …………………………………………..1
I-1. Package Content………………………………………………………1 I-2. Hardware Overview …………………………………………………1 I-3. LED Status ………………………………………………………………2
II. Installation………………………………………………………2
II-1. Physically Setup……………………………………………………….2 II-2. Connection ……………………………………………………………..4
III. Web-based Configuration Utility ………………………..5 IV. More Information ……………………………………………7 V. Safety Instructions ……………………………………………7
I.Product Information
GS-5210PLG is a 10-Port Gigabit Long Range PoE+ Web Smart Switch with 1 Gigabit RJ45 and 1 SFP Ports.
I-1. Package Content
GS-5210PLG
Quick Installation Power Cord Rack-Mount Kit Guide
I-2. Hardware Overview
LED (PoE/Alert,
LED
Gigabit PoE Port
PWR)
(Link/Act 1~8)
(1~8)
Gigabit RJ45 Port (9)
Reset
AC
Power Socket
PoE LED (Link/Act 1~8)
1
SFP Port (10)
I-3. LED Status
Function
Color
PWR
Green
PoE Alert Green
Link/ACT (Port 1-9)
Green Amber
SPF (Port 10)
PoE (Port 1-8)
Green Green
Status On Off
Blinking
On
Off
On Blinking
Off On Blinking Off On Blinking Off On Off
Description
Power on
Power off
Booting up
Total PoE power consumed is OVER PoE power budget
Total PoE power consumed is under PoE power budget
Link at 1000Mbps Sending or receiving data Port disconnected or link fail Link at 10/100Mpps Sending or receiving data Port disconnected or link fail Link at 1000Mbps Sending or receiving data Port disconnected or link fail Feeding power to PoE devices PoE function is not active
II.Installation
Read the following below procedures in the correct order. Incorrect installation may cause damage to the product.
II-1. Physically Setup
There are two ways to physically set up the switch.
1. Desktop Placement: Place the switch on a flat surface and install the four rubber feet (included) on the bottom of the switch.
2
2. Rack-mount the switch: You can mount the switch in any standard size, 19-inch (about 48 cm) wide rack with 1 Rack Unit (1U) of space, which is 1.75 inches (4.45 cm) high. A pair of extension brackets and screws are needed to adapt the switch to the rack size. Align the mounting brackets with the mounting holes on the switch’s side panels and secure the brackets with the screws.
Secure the switch on the equipment rack.
3
II-2. Connection
1. Power on: Connect the power cord to the switch and the power outlet. The switch is powered by the 100-240VAC 50/60Hz external highperformance power supply. (Note: Make sure the PWR LED is green.)
2. Uplink: Plug the standard Cat5e Ethernet cable into the LAN port no. 9 or plug the SFP cable into the SFP slot and connect it to the LAN server or core switch. (Note: Make sure that the LED is green or amber.)
3. Connect devices: Plug the standard Cat5e Ethernet cable into the LAN port and connect to any networking device with an Ethernet port. (Note: Make sure that the “LAN” LED is green or amber.) The hardware installation is complete!
4. Connect a computer: Connect your computer with the switch and get ready for web-based configuration with following Section III Web-based Configuration Utility.
1. Power on
2. Uplink to the server or core switch
4. Connect to a computer
3. Connect devices
4
III.Web-based Configuration Utility
This section describes how to navigate the web-based switch configuration utility through web browser. Be sure to disable any browser pop-up blocker.
Browser Restrictions
If you are using older versions of Internet Explorer, you cannot directly use an IPv6 address to access the device. You can, however, use the DNS (Domain Name System) server to create a domain name that contains the IPv6 address, and then use that domain name in the address bar in place of the IPv6 address.
If you have multiple IPv6 interfaces on your management station, use the IPv6 global address instead of the IPv6 link local address to access the device from your browser.
Launching the Configuration Utility
1. Connect your computer with the switch then open a web browser.
2. Enter the IP address of the switch you are configuring in the address bar on the browser (factory default IP address is 192.168.2.1) and then press Enter. Please make sure that your computer’s IP address is in the same subnet as this switch. The default IP address is an IP address in the range of 192.168.2.X (X=2-254). You can modify the IP address of your computer if you need.
Default IP Default User Name Default Password
192.168.2.1 admin 1234
5
3. The default username is “admin” and the default password is “1234”.
4. The first time that you log in with the default username and password, you are required to set a new password.
5. For more information about Web-based Configuration Utility, please download User Manual from EDIMAX official website. https://www.edimax.com/download/
6
IV.More Information
For detailed instructions, you can find user manual and all supporting documents from the link below or via the QR code:
https://www.edimax.com/download/
Please search the model name “GS-5210PLG” to enter the referred page.
V.Safety Instructions
The following general safety guidelines are provided to help ensure your own personal safety and protect your product from potential damage. Remember to consult the product user instructions for more details.
This product is designed for indoor use only. Static electricity can be harmful to electronic components. Discharge static
electricity from your body (i.e. touching grounded bare metal) before touching the product. The device contains no user serviceable parts. Do not attempt to service the product and never disassemble the product. Do not spill food or liquid on your product and never push any objects into the openings of your product. Do not use this product near water, areas with high humidity, or condensation. Keep the product away from radiators and other heat sources. This device is not designed to be operated by children. Always unplug the product from mains power before cleaning and use a dry lint free cloth only.
7
COPYRIGHT
Copyright Edimax Technology Co., Ltd. all rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual or otherwise, without the prior written permission from Edimax Technology Co., Ltd. Edimax Technology Co., Ltd. makes no representations or warranties, either expressed or implied, with respect to the contents hereof and specifically disclaims any warranties, merchantability, or fitness for any particular purpose. Any software described in this manual is sold or licensed as is. Should the programs prove defective following their purchase, the buyer (and not this company, its distributor, or its dealer) assumes the entire cost of all necessary servicing, repair, and any incidental or consequential damages resulting from any defect in the software. Edimax Technology Co., Ltd. reserves the right to revise this publication and to make changes from time to time in the contents hereof without the obligation to notify any person of such revision or changes. The product you have purchased and the setup screen may appear slightly different from those shown in this QIG. The software and specifications are subject to change without notice. Please visit our website www.edimax.com for updates. All brand and product names mentioned in this manual are trademarks and/or registered trademarks of their respective holders.
8
Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
FCC Radiation Exposure Statement This device complies with FCC radiation exposure limits set forth for an uncontrolled environment and it also complies with Part 15 of the FCC RF Rules. This equipment must be installed and operated in accordance with provided instructions and the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and consider removing the no-collocation statement.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Caution! Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
R&TTE Compliance Statement This equipment complies with all the requirements of DIRECTIVE 2014/30/EU OF THE EUROPEAN PARLIAMENT AND THE COUNCIL of March 9, 1999 on radio equipment and telecommunication terminal equipment and the mutual recognition of their conformity (R&TTE). The R&TTE Directive repeals and replaces in the directive 98/13/EEC (Telecommunications Terminal Equipment and Satellite Earth Station Equipment) As of April 8, 2000.
Safety This equipment is designed with the utmost care for the safety of those who install and use it. However, special attention must be paid to the dangers of electric shock and static electricity when working with electrical equipment. All guidelines of this and of the computer manufacture must therefore be allowed at all times to ensure the safe use of the equipment.
EU Countries Intended for Use The ETSI version of this device is intended for home and office use in Austria, Belgium, Bulgaria, Cyprus, Czech, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Turkey, and United Kingdom. The ETSI version of this device is also authorized for use in EFTA member states: Iceland, Liechtenstein, Norway, and Switzerland.
EU Countries Not Intended for Use None
9
EU Declaration of Conformity
English: This equipment is in compliance with the essential requirements and other relevant
provisions of Directive 2014/30/EU.
Français: Cet équipement est conforme aux exigences essentielles et autres dispositions de la
directive 2014/30/EU.
Cestina: Toto zaízení je v souladu se základními pozadavky a ostatními píslusnými ustanoveními
smrnic 2014/30/EU.
Polski:
Urzdzenie jest zgodne z ogólnymi wymaganiami oraz szczególnymi warunkami
okrelonymi Dyrektyw UE 2014/30/EU.
Român: Acest echipament este în conformitate cu cerinele eseniale i alte prevederi relevante ale
Directivei 2014/30/EU.
:
2014/30/EU.
Magyar: Ez a berendezés megfelel az alapvet követelményeknek és más vonatkozó irányelveknek
(2014/30/EU).
Türkçe: Bu cihaz 2014/30/EU. direktifleri zorunlu istekler ve dier hükümlerle ile uyumludur.
: 2014/30/EU.
Slovencina: Toto zariadenie spa základné poziadavky a alsie príslusné ustanovenia smerníc
2014/30/EU.
Deutsch: Dieses Gerät erfüllt die Voraussetzungen gemäß den Richtlinien 2014/30/EU.
Español: El presente equipo cumple los requisitos esenciales de la Directiva 2014/30/EU.
Italiano: Questo apparecchio è conforme ai requisiti essenziali e alle altre disposizioni applicabili
della Direttiva 2014/30/EU.
Nederlands: Dit apparaat voldoet aan de essentiële eisen en andere van toepassing zijnde bepalingen
van richtlijn 2014/30/EU.
Português: Este equipamento cumpre os requesitos essênciais da Directiva 2014/30/EU.
Norsk:
Dette utstyret er i samsvar med de viktigste kravene og andre relevante regler i Direktiv
2014/30/EU.
Svenska: Denna utrustning är i överensstämmelse med de väsentliga kraven och övriga relevanta
bestämmelser i direktiv 2014/30/EU.
Dansk: Dette udstyr er i overensstemmelse med de væsentligste krav og andre relevante
forordninger i direktiv 2014/30/EU.
suomen kieli: Tämä laite täyttää direktiivien 2014/30/EU. oleelliset vaatimukset ja muut asiaankuuluvat
määräykset.
——————————————————————————————————————-
WEEE Directive & Product Disposal At the end of its serviceable life, this product should not be treated as household or general waste. It should be handed over to the applicable collection point for the recycling of electrical and electronic equipment, or returned to the supplier for disposal.
10
Declaration of Conformity
We, Edimax Technology Co., Ltd., declare under our sole responsibility, that the equipment described below complies with the requirements of the European R&TTE directives.
Equipment: 9-port Gigabit + 1-port SFP Smart-lite Ethernet Switch w/ 8 PoE+ ports Model No.: GS-5210PLG
The following European standards for essential requirements have been followed:
Directives 2014/30/EU
EMC
: EN 55032:2015+AC:2016
EN 61000-3-2:2014 Class A
EN 61000-3-3:2013
EN 55035:2017
Directives 2014/35/EU
Safety (LVD) : EN 62368-1:2014+A11:2017
Edimax Technology Europe B.V. Fijenhof 2, 5652 AE Eindhoven, The Netherlands Date of Signature: March, 2022 Signature:
a company of: Edimax Technology Co., Ltd. No. 278, Xinhu 1st Rd., Neihu Dist., Taipei City, Taiwan Date of Signature: March, 2022 Signature:
Printed Name: Title:
David Huang Director Edimax Technology Europe B.V.
Printed Name: Title:
Hunter Chen Director Edimax Technology Co., Ltd.
11
Declaration of Conformity
We, Edimax Technology Co., Ltd., declare under our sole responsibility, that the equipment described below complies with the requirements of the United Kingdom EMC and Safety directives.
Equipment: 9-port Gigabit + 1-port SFP Smart-lite Ethernet Switch w/ 8 PoE+ ports Model No.: GS-5210PLG
The following European standards for essential requirements have been followed:
Electromagnetic Compatibility Regulations 2016 (S.I. 2016/1091)
EMC
: EN 55032:2015+AC:2016
EN 61000-3-2:2014 Class A
EN 61000-3-3:2013
EN 55035:2017
Electrical Equipment (Safety) Regulations 2016 (S.I. 2016/1101)
Safety (LVD) : EN 62368-1:2014+A11:2017
Edimax Technology Europe B.V. Fijenhof 2, 5652 AE Eindhoven, The Netherlands Date of Signature: March, 2022 Signature:
a company of: Edimax Technology Co., Ltd. No. 278, Xinhu 1st Rd., Neihu Dist., Taipei City, Taiwan Date of Signature: March, 2022 Signature:
Printed Name: Title:
David Huang Director Edimax Technology Europe B.V.
Printed Name: Title:
Hunter Chen Director Edimax Technology Co., Ltd.
12