ProSoft L24ER Rockwell Automation User Manual
Ethernet and Serial Gateway Solutions
ProSoft Technology’s stand-alone, DIN rail-mounted industrial gateways provide a means to read or write data from devices using dissimilar protocols. All gateways come with our ProSoft Discovery Service feature. With PDS, you don’t have to change your PC to the default subnet of the module, saving you time during setup.
Building Automation solutions – including QuickServer gateways
bring key operational data directly to your Rockwell Automation controller. Use these solutions to boost energy efficiency, use the resource most productively, and decrease your usage and costs.
- Gateways with two Ethernet ports allow you to isolate networks, passing only the data you want between devices
- EtherNet/IP™ gatewayssupport multiple I/O connections for fast real-time data
- Remote configuration and diagnostics via Ethernet
- SD Card slot for disaster recovery of configuration data
- Up to four Serial ports

PROFIBUS DP & many other protocols are also available
- The CANOpen Router is an ideal solution for motion-oriented machine control systems, primarily in automotive applications. The module supports EtherNet/IP to CANOpen communications, and can support either Master or Slave mode.
- The J1939 Router enables automotive diagnostic communications via EtherNet/IP between Logix controllers and J1939 devices. The module is used to facilitate automatic unpacking and scaling of J1939 devices’ data to your controller’s UDT structure, saving you time.
- The Time Sync Module enables precise time syncing with Logix controllers and HMIs, and provides GPS data as well for inertial navigation applications. Velocity and odometer data is available thanks to the onboard GPS receiver.
- The XPosition Module delivers highly precise location data from GPS or inertial navigation devices,ensuring you know the placement of your crane system, marine crafts, or drilling equipment.
Serial & Ethernet Modbus® Solutions
Modbus® Serial
- Module configuration stored within the Studio 5000®/RSLogix™ 5000 project (ACD file) for simplified disaster recovery
- Add-On Profile (AOP) improves integration into Studio 5000/RSLogix 5000
- Add-On Instruction (AOI) reduces configuration effort and simplifies maintenance Scalable Modbus® & Modbus® TCP Solutions for CompactLogix™
- Enhanced modules allow up to 10,000 I/O words
- Lite modules allow up to 240 I/O words
- Integrated Modbus® Serial communications in 1734 Point I/O™ applications
- Modules also available for the Logix-XT platform; support operations in extreme environments at higher operating temperatures, and have a conformal coating to protect them in harsh conditions.

Modbus® TCP/IP
- Fast Multi-Server/MultiClient capabilities
- Add-On Instruction reduces configuration effort and simplifies maintenance.

Scalable Modbus® & Modbus® TCP Solutions for CompactLogix
Enhanced modules allow up to 10,000 I/O words- Lite modules allow up to 240 I/O words
- Integrated Modbus® Serial communications in 1734 Point I/O™ applications


Secure Remote Connectivity
Our Secure Remote Access suite, easy to use by design, provides IT-secure and OT-friendly solutions that help you connect to your equipment anywhere, at any time. Remote access gateways and always-on networks can be monitored securely and easily in Belden Horizon™, Belden’s cloud-native service.
We aim to make remote access as secure and streamlined as possible, and put the end user in the driver’s seat, ensuring complete access control of remote equipment. Our remote access solutions feature:
- Virtual Lockout-Tagout feature for greater access control of specific equipment
- A multi-layered Defense-in-Depth approach to security, including advanced two-factor authentication (we avoid the less-secure SMS mode of authentication) and Active Directory support via Single Sign-On (SSO), which means you can access Belden Horizon with your corporate login credentials
- Role-based device and user access
- No software updates on your part – no userinstalled software means you’ll eliminate an entry point for hackers, and save time for your team
- OpenVPN support: One-time-use tunnels provide a secure connection between your equipment and Belden Horizon
- Layer 2 Tunneling Protocol (L2TP)/IPSec and Secure Socket Tunneling Protocol (SSTP) support increases VPN security for all popular clients, including Windows, iOS, and Android products, and easily allows you to see your remote devices rather than try to remember them
- Support for SMS messaging from your EtherNet/IP or Modbus TCP/IP PAC (Cellular Gateway only)
Persistent Data Network (PDN)
Always-on, secure, and managed cloudbased network to connect geographically dispersed remote sites. This simple, secure solution is ideal for infrastructure communications networks.
Gateways
Industrial Cellular Gateway (ICX35-HWC)
- 4G LTE cellular or wired access via WAN/LAN port’
- Ethernet port available for Internet connection or SIM card
- Monitor and manage via Belden Horizon
Network Bridge (PLX35-NB2)
- Wired remote access
- Monitor and manage via Belden Horizon
- Enable / Disable remote access locally via an EtherNet/IP message
- File Relay – transfer files across segmented networks
Data Logger Plus (PLX51-DLplus-232)
- Ideal for remote sites with limited communications that need to log data (stores over 16M records!)
- Can help OEMs identify operational issues and improve OEE
- Data can be downloaded as a .csv file
- Support for 200 tags; minimum log interval: 50 milliseconds
- Features support for JSON interface, enabling easy exporting of logged data to business CRM systems
- Features an integrated webserver to trend variables and upload logged data
- XLReporter connection available
Belden Horizon Platform
- EasyBridge™ technology enables your PC to act like it is connected directly to a switch on the remote network
- Allows software tools, such as RSWho and Studio 5000, to work without routing
- Multi-layered defense-in-depth approach, including support for Active Directory (SSO) and token-based 2F Authentication, keeps your data and equipment safe
Belden Horizon Lite App
What if you’re not at your desk or office when the customer call comes in, or sitting on a beach and your customer calls with a critical issue? You don’t have to give up that view or worry you’ll upset your customer – Belden Horizon has gone mobile, and the app is available to download on the iOS or Android platform!

Before
After
ControlLogix®
CompactLogix™
For Multi-Well Pad and LACT Applications
- Supports 8-16 meter runs with 4 streams per meter run for the measurement of hydrocarbon gases and liquids
- In-chassis solution brings data directly into your ControlLogix® or CompactLogix™; helps minimize cabinet space
- Pair with Rockwell Automation’s distributed I/O capability + ProSoft’s wireless radios to reduce wiring to transmitters and I/O devices
- Includes the use of EAFC Manager, a free Windows 7-based tool for configuration, reporting, and monitoring; hourly or daily archives with user-selected data are available
- NMi certified for OIML, WELMEC, and MID type approval (AGA/API)
- No additional licensing fee for liquid meter runs
- Add another AFC card in same chassis if more meter runs are required
- Secure data archiving / meter run
- Archive records stored in non-volatile memory in module
- Archive data cannot be altered/changed
- Integration to SCADA with Modbus/Enron Modbus support (Cygnet, Autosol, and FlowCal)
- System designs can support more than 80 metering locations.
HART Solutions
Gain additional diagnostic information from your distributed process equipment – and boost efficiency as a result.
Power and Energy Solutions
Connecting your Rockwell Automation controller to intelligent electronic devices (IEDs), including substation power monitors and relays.
Those devices’ data can then be used for IED integration and substation automation, as well as be sent to the utility enterprise level. ProSoft has a variety of modules that can help you extend your power and energy application’s Connected Enterpris.
IEC 61850 Solutions
IEC 61850 Client Module
- Allows ControlLogix® PACs to interface with IEC 61850 IEDs, including power protection equipment; features support for up to 40 IEC 61850 Server devices on the network
- Supports up to 225 I/O connections to ControlLogix PAC
- Supports MMS and GOOSE messaging, helping you eliminate hard-wired I/O signals for interlocking of protection relays and load shedding applications
- Streamlined configuration: Highly integrated into Studio 5000 with Add-On Profile; custom Add-On Instruction available
- An IEC 61850 Server Module is also available for ControlLogix PACs.

IEC 61850 Gateway
- Fast, real-time data transfers with a maximumof 10,000 bytes in and 9,920 out (PLX82)
- Polls up to 20 IEC 61850 server devices
- Application-specific Add-On Instructions are automatically generated
- IEC 61850 IED tags are created in your Studio 5000®/RSLogix 5000™ Project, reducing configuration time and errors.

- Other protocol solutions are available, including modules supporting IEC-60870-5-101/103/104, Modbus, PROFIBUS, and PROFINET
DNP3 Solutions
Connect power and energy, oil and gas, or water and wastewater sites with industrial DNP3 solutions.
DNP3 Master and Slave Gateways
The PLX51-DNPM and -DNPS gateways enable intelligent routing between DNP3 and EtherNet/IP or Modbus protocols. Adding these modules into your SCADA and telemetry system will help you reliably capture key data with no holes, with timeand date-stamped data at the source.
- Supports secure authentication
- Optimized for Rockwell Automation architectures
- Flexible and easy to configure
PLX51-DNPM In Data Concentrator Mode with ProSoft PDN
1761-NET-ENI Replacement – Update Your Legacy DF1 Systems
Need a 1761-NET-ENI now that it’s been discontinued? The Routing Module can be used in nearly every application as the NET-ENI. Now you can modernize your legacy DF1 control system in phases using your OpEx budget.
Intelligent routing to ControlLogix® or CompactLogix™ from PLC-5, SLC, MicroLogix™ controllers- Direct-to-tag technology simplifies data mapping, reducing configuration time.

1761-NET-AIC Replacement – Update your legacy DH485 systems
Need a 1761-NET-AIC replacement? This module can be used in nearly every application as the NET-AIC. Now you can modernize your legacy DH485-based system in phases using your OpEx budget.
Intelligent data routing between DH485 and EtherNet/IP devices- Direct-to-tag technology simplifies data mapping, reducing configuration time
- 2-port unmanaged switch or Device Level Ring (DLR) support

ControlNet and DeviceNet Modernizations
ControlNet Router: Connect existing equipment to new EtherNet/IP -using PanelView Plus terminals – without having to do some major re-cabling. The module also supports Device Level Ring networks or can be used as a two-port Ethernet switch.
DeviceNet Router: Enables data exchanges via EtherNet/IP between DeviceNet devices and your Logix controller or a PanelView Plus terminal. The DeviceNet data can be mapped to a PLC5 type address file; from there, an Ethernet device (such as a PanelView)can either write to or read the data.
PROFIBUS Solutions]
ProSoft’s PROFIBUS DP modules are ideal for the most demanding applications

For ControlLogix®
Through premier integration tools, you can minimize the time required to get a PROFIBUS DP network configured in a ControlLogix environment.
Master/multi-slave module:
Can transfer up to 5000 bytes of cyclic I/O data with various slave devices on the network.
Multi-slave module: Can pass up to 2440 bytes of input and output data as high-speed cyclic I/O data on a PROFIBUS DP network.
For CompactLogix™
Master module: Supports remote Ethernet connectivity with Asset Management Software, significantly lowering your maintenance costs.
Slave module: Supports DPV1 Acyclic Messaging; Add-On Profile provided to allow for seamless integration to Studio 5000 and RSLogix 5000.
Gateways
Master and Slave gateways connect PROFIBUS DP equipment to devices using EtherNet/IP, Modbus Serial, or Modbus TCP/IP. PROFIBUS DP network commissioning time can be greatly reduced with the modules’ built-in PROFIBUS DP packet capture utility. With support for up to 1536 bytes of Input and Output data, and up to 4 EtherNet/IP connections back to the processor, the modules provide performance and data throughput for even the most demanding of PROFIBUS applications.
Siemens® Communications and Migrations
Siemens Industrial Ethernet gateways can be used to foster connections between equipment using the protocol and EtherNet/IP or Modbus TCP/IP devices. ProSoft’s modules include 2-port gateways that allow each protocol to reside on separate subnets, allowing you to pass data between the two subnets without changing each device’s IP address. The gateways’ Add-On Profiles allow for simplified integration and reduced commissioning time.
In-chassis modules are available to help you share data between your new Rockwell Automation controller and your existing Siemens Industrial Ethernet PLC.
PROFINET Gateways
- PROFINET Controller and Device Gateways connect to EtherNet/IP-based systems.
- Gateways with two Ethernet ports allow you to isolate networks, passing only the data you want between devices
- EtherNet/IP gateways support multiple I/O connections for fast real-time data
Enterprise Connectivity
Linux Development Modules
Connect Your Logix Processor to ThingWorx or to a MQTT Broker
These edge-compute modules are ideal for custom algorithm applications, including the transfer of key operational data. The ControlLogix module’s library has sample applications (complete with source code!) for ThingWorx®, Sparkplug B MQTT, and standard MQTT. These samples help enable direct connectivity, expanding your IIoT application.
- In-chassis modules simplify your site and bring data directly into your ControlLogix or CompactLogix; help minimize cabinet space
- Linux Virtual Machine (VM) and C/C++ development environment provided on separate DVD
- VM contains preinstalled toolchain and libraries.


Leverage the IIoT
Collect, store, and analyze data to realize measureable business improvements
There’s operational data within nearly every piece of equipment in your application – and you can use it to make changes that will positively affect your facility. ProSoft’s in-chassis modules and standalone gateways have been used for 30 years to connect disparate equipment, the first step on the path to showing ROI from your IIoT improvements.
Industrial gateways and wireless radios enable communications between equipment in busy facilities, helping you maintain production and meet increased consumer demand.
Logistics
Increased consumer demand for goods bought online has heightened the need for reliable, ontime delivery of man household goods. Industrial protocol gateways and wireless radios can help ensure accurate production and distribution; real-time communications between moving equipment such as smart conveyors and automated guided vehicles (AGVs); and the safety of on-site employees in increasingly mobile applications.
Real Word Example
A logistics end user needed to find a reliable alternative to slip rings for aconveyor application. Wireless radios now communicate with their CompactLogix. psft.com/DEA
Fiat Chrysler increased production flexibility – and saved downtime – when they paired wireless radios with new Rockwell Automation controllers. psft.com/DD4
A perfume manufacturer produces its samples thanks to improved communication with their scale. psft.com/DEB
A UK end user needed to transport materials within its automotive facility. The machine builder Mirage paired AGVs with wireless radios psft.com/DD9 R
Automotive
Automotive production is an intricate process whose automated elements rely on realtime communications.
Moving parts throughout a facility – whether they’re half-finished vehicle frames moving down a production line or AGVs ferrying supplies – require reliable communications to protect workers and product throughout the site. Ultra-Fast Industrial Hotspots can help.
Real-World Examples Fiat Chrysler increased production flexibility – and saved downtime – when they paired wireless radios with new Rockwell Automation controllers. psft.com/DD4
A UK end user needed to transport materials within its automotive facility. The machine builder Mirage paired AGVs with wireless radios psft.com/DD9
Amusement
At the top of any amusement end user or machine builder’s mind is the need to maintain riders’ safety.
Using wireless communications over CIP Safety helps increase communications for thrilling rides – as well as the safety of everyone on-board.
Real Word Example
Safety on the Skyfall: The company Funtime added radiating cable and a wireless radio to best monitor this freefall ride’s signals. psft.com/DEC
Improvements to the Disk’O Coaster: Using a wireless Ethernet-based solution paired with a safety protocol helped this ride manufacturer improve the data rate of communication. psft.com/DED
802.11n (abgn) Fast Industrial Hotspots
- Ultra-Fast access point switchover times of less than 10 ms are perfect for applications such as automated storage-retrieval systems, AGVs, and automotive skillet lines
- EtherNet/IP™ embedded object and Modbus® agent support lets users get radio diagnostics into their PAC/PLC, where the information can be analyzed and acted upon, helping to reduce downtime
- WPA/WPA2-Personal (PSK, AES and/or TKIP); WPA/WPA2-Enterprise (IEEE 802.1X/RADIUS, AES and/or TKIP)
- Secure digital configuration storage for quick field replacement
- Radios support wireless safety Ethernet networks, ideal for tomated material handling applications.
2.4 GHz and 5 GHz High-Power Industrial Hotspots are also available for longer-distance applications.

802.11abgn Wireless Plant Architecture
- 2.4 GHz or 5 GHz HighSpeed Wireless Network
Radiating Cable 2.4 and 5 GHz Band
Acting as a long, flexible antenna, Radiating Cable is an alternative to traditional RF antenna systems.
Features
- Special coaxial shield design uses slots to radiate RF Signals
- Available in variable lengths
- Pre-assembled cable for easy installation
- Frequency Range: 2.4 GHz, 5 GHz to 6 GHz
Benefits
- Wireless signal more stable in terms of response time – useful in communicating with I/O
- Used in metallic environments, rotating/spinning machines, conveyors, AGVs, warehousing, and more

802.11n (abgn) Fast Watertight Industrial Hotspots
- IP67 water/dust-rated
- Designed for extreme temperatures (-40° to +70°C), high vibration/shock and hazardous locations (UL C1D2, ATEX Zone 2)
- Ultra-Fast Roaming with under 10 ms switchover times maintains connections for moving machines/platforms.
- Power over Ethernet (PoE)
- QoS and VLAN for optimum traffic management
- WPA/WPA2-Personal (PSK, AES and/or TKIP)
- WPA/WPA2-Enterprise (IEEE 802.1X/ RADIUS, AES and/or TKIP)

Wireless Support from Trusted Experts
Designing and implementing a wireless network is a major investment. ProSoft’s wireless field application engineers can help ensure a smooth design and installation for your application. Our professional wireless services include:
- Expert Phone Support
- Engineering Drawing Review
- Site Surveys
- Configuration Support
- Troubleshooting

Wireless Comparison Product Selection Chart
| Model | 802.11abgn Weatherproof Industrial Hotspot | 802.11abgn Fast Industrial Hotspot | Industrial Cellular Gateway |
| RLX2-IHNF-W(C) | RLX2-IHNF | ICX35-HWC | |
| Features & Specifications | |||
| Device Connectivity | Ethernet | Ethernet/Serial | Ethernet/Serial |
| Frequency Band(s) | 2.4 & 5 GHz | 2.4 & 5 GHz | Cellular |
| Regions Unlicensed Use Allowed | Global | Global | Global |
| Wireless Technology | IEEE 802.11abgn | IEEE 802.11abgn | 4G LTE Cellular HSPA |
| Max Outdoor Range (miles/km) | 5 mi /8 km | 5 mi /8 km | Unlimited |
| Fast Roaming | Yes | Yes | N/A |
| Repeater Mode | Yes | Yes | N/A |
| Max RF Data Rate | 300 Mbps | 300 Mbps | N/A |
| Security/Encryption | 802.11i / 128 bit AES | 802.11i / 128 bit AES | Internal Firewall, Belden Horizon VPN, OpenVPN, IPSec |
| RF Based IGMP Querying | Yes | Yes | N/A |
| Self-Healing Network | Yes | Yes | N/A |
| Advanced Diagnostics (signal strength LEDs, web server, network management software, OPC tag server, SNMP) | Yes | Yes | N/A |
| Hazardous Location Approvals | Class 1, Div 2/ Atex Zone 2 (WC) | Class 1, Div 2/ Atex Zone 2 | Class 1, Div 2 |
| Outdoor/Wash Down Rated Model | IP67 | N/A | N/A |
| Wireless Applications | |||
| Long-Range SCADA | N/A | N/A | Yes |
| Short-Range SCADA | Yes | Yes | Yes |
| Mobile Worker (Wi-Fi) | Yes | Yes | N/A |
| EtherNet/IP™ Object | Yes | Yes | Yes |
| EtherNet/IP™ Implicit Messaging (High-Speed IO) | Yes | Yes | N/A |
| Serial DF1, ASCII, Modbus®, DNP3, etc. | N/A | Yes (encapsulation) | Yes (encapsulation) |
| Video | Fast Frame Rate | Fast Frame Rate | Yes |
| Check for product availability in your country. | |||
In-Chassis Product Selection Chart
| Platform | ControlLogix® | CompactLogix™ | Point I/O |
| Protocol/Application | |||
| AGA/API Gas & Liquid Flow Computer | MVI56E-AFC | MVI69E-AFC | |
| Moore APACS+ I/O | CLX-APACS | ||
| ASCII | MVI56E-GSC MVI56E-GSCXT | MVI69E-GSC | |
| BASIC | MVI56-BAS | ||
| ‘C’ Programmable | MVI56E-LDM | MVI69E-LDM | |
| DF1 | PLX51-DF1-ENI | PLX51-DF1-ENI | |
| DNP3 Serial | MVI56-DNP | MVI69-DNP | |
| DNP3 Ethernet | MVI56E-DNPNET | MVI69-DNPSNET | |
| EtherNet/IP™ | MVI69-DFNT | ||
| FA Control/Network | MVI56E-FLN | ||
| GE Ethernet Global Data | MVI56-EGD | MVI69-EGD | |
| Generic Ethernet ASCII | MVI56E-GEC | MVI69E-GEC | |
| IEC 60870-5-101 Slave | MVI56-101S | ||
| IEC 60870-5-101 Master | MVI56-101M | ||
| IEC 60870-5-104 Server | MVI56-104S | MVI69-104S | |
| IEC 61850 Client | MVI56E-61850C | ||
| IEC 61850 Server | MVI56E-61850S | ||
| Limitorque Master | MVI56-LTQ | ||
| Modbus® Serial | MVI56E-MCM MVI56E-MCMR MVI56E-MCMXT | MVI69E-MBS MVI69L-MBS | ILX34-MBS232 ILX34-MBS485 |
| Modbus® TCP/IP | MVI56E-MNET MVI56E-MNETC MVI56E-MNETR MVI56E-MNETCR MVI56E-MNETXT | MVI69E-MBTCP MVI69L-MBTCP | |
| PROFIBUS DP Master | ILX56-PBM | ILX69-PBM | |
| PROFIBUS DP Slave | ILX56-PBS | ILX69-PBS | |
| Siemens® 3964R | MVI56-S3964R | MVI69-S3964R | |
| Siemens® Industrial Ethernet | MVI56E-SIE | ||
Many of ProSoft’s in-chassis and gateway modules for Rockwell Automation systems feature Add-On Instructions or Add-On Profiles to help you increase efficiency and reduce configuration. Learn more: psft.com/DCC
| Protocol/Application | ||||||||||||
| Application/Protocol | ASCII | DF1 Master/Slave | DNP 3.0(Serial + Ethernet) | EtherNet/IP™ | HART Multidrop/ Analog (4 chl) | IEC 60870-5-104Server | Modbus® Serial | Modbus® TCP/IP | OPC UA | PROFIBUS DPMaster | PROFIBUS DPSlave | PROFINET |
| ASCII | PLX31-EIP-ASCII PLX31-EIP-ASCII4 | Contact support | ||||||||||
| BACnet®/IP, BACnet® MS/TP | PS-QS-2010-F (250 Pt)PS-QS-2210-F (500 Pt) | PS-QS-2010-F (250 Pt)PS-QS-2210-F (500 Pt) | PS-QS-2010-F (250 Pt)PS-QS-2210-F (500 Pt) | PS-QS-2010-F (250 Pt)PS-QS-2210-F (500 Pt) | ||||||||
| DF1 Master/Slave | Contact support PLX51-DL-232 PLX51-DLplus-232 | PLX51-DF1-ENI PLX51-DF1-MSG | Contact support | Contact support | Contact support | |||||||
| DH485 | A-DH485R/B | |||||||||||
| DNP 3.0(Serial + Ethernet) | PLX51-DNPM PLX51-DNPS | PLX51-HART-4I(4 channel) | PLX51-DNPM PLX51-DNPS | PLX51-DNPM PLX51-DNPS | Contact support | |||||||
| EtherNet/IP™ | PLX31-EIP-ASCII PLX31-EIP-ASCII4 | PLX51-DF1-ENI PLX51-DF1-MSG | PLX51-DNPM PLX51-DNPS | PLX35-NB2 | PLX51-HART-4I(4 channel) PLX51-HART-4O | PLX32-EIP-104 | PLX31-EIP-MBS PLX31-EIP-MBS4 | PLX31-EIP-MBTCP PLX32-EIP-MBTCP PLX32-EIP-MBTCP-UA A-XGPS | PLX32-EIP-MBTCP-UA | PLX51-PBM | PLX51-PBS | PLX31-EIP-PND PLX32-EIP-PND PLX82-EIP-PNC |
| HART® Analog | PLX51-HART-4I PLX51-HART-4O | |||||||||||
| HART® Multi-drop | PLX51-HART-4I | PLX51-HART-4I PLX51-HART-4O | PLX51-HART-4I PLX51-HART-4O | |||||||||
| IEC 60870-5-101 Slave | ||||||||||||
| IEC 60870-5-104 Server | PLX32-EIP-104 | PLX32-MBTCP-104 | ||||||||||
| IEC 61850 | PLX82-EIP-61850 | PLX82-MNET-61850 | ||||||||||
| LonWorks™ | PS-QS-1011-0783 (250 Pt)PS-QS-1511-0783 (500 Pt) | PS-QS-1011-0783 (250 Pt)PS-QS-1511-0783 (500 Pt) | PS-QS-1011-0154 (250 Pt)PS-QS-1511-0154 (500 Pt) | PS-QS-1011-0154 (250 Pt)PS-QS-1511-0154 (500 Pt) | ||||||||
| Metasys® N2 | PS-QS-2010-F (250 Pt)PS-QS-2210-F (500 Pt) | PS-QS-2010-F (250 Pt)PS-QS-2210-F (500 Pt) | PS-QS-2010-F (250 Pt)PS-QS-2210-F (500 Pt) | PS-QS-2010-F (250 Pt)PS-QS-2210-F (500 Pt) | ||||||||
| Modbus® Serial | PLX51-DNPS PLX51-DNPM | PLX31-EIP-MBS PLX31-EIP-MBS4 | Contact support | Contact support | PLX51-PBM | PLX51-PBS | PLX31-PND-MBS PLX31-PND-MBS4 | |||||
| Modbus® TCP/IP | Contact support | PLX51-DNPS PLX51-DNPM | PLX31-EIP-MBTCP PLX32-EIP-MBTCP PLX32-EIP-MBTCP-UA A-XGPS | PLX51-HART-4O PLX51-HART-4I | PLX32-MBTCP-104 | PLX32-EIP-MBTCP-UA | PLX51-PBM | PLX51-PBS | PLX31-MBTCP-PND PLX32-MBTCP-PND PLX82-MBTCP-PNC | |||
| OPC UA | PLX32-EIP-MBTCP-UA | PLX32-EIP-MBTCP-UA | ||||||||||
| PROFIBUS DP | PLX51-PBM PLX51-PBS | PLX51-PBM PLX51-PBS | PLX51-PBM PLX51-PBS | |||||||||
| PROFIBUS PA | A-PAL/B | A-PAL/B | ||||||||||
| PROFINET | PLX31-EIP-PND PLX32-EIP-PND PLX82-EIP-PNC | PLX31-PND-MBS PLX31-PND-MBS4 | PLX31-MBTCP-PND PLX32-MBTCP-PND PLX82-MBTCP-PNC | |||||||||
| Siemens® Industrial Ethernet | PLX31-EIP-SIE PLX32-EIP-SIE | PLX31-MBTCP-SIE PLX32-MBTCP-SIE | ||||||||||
| CAN Protocols (CAN Open, DeviceNet, J1939) | A-CANOR/B A-DNTRA-J1939R | A-CANOR/B | ||||||||||
| ControlNet | A-CNR | |||||||||||
| PTP/NTP | A-TSM | |||||||||||
| Data Logging | PLX51-DL-232 PLX51-DLplus-232 | PLX51-DL-232 PLX51-DLplus-232 | PLX51-DL-232 PLX51-DLplus-232 | |||||||||
Asia Pacific
Regional Office
Phone: +603.2242.2020
[email protected]
Languages: Bahasa, Chinese,
English, Japanese, Korean
Regional Tech Support
[email protected]
North Asia (China, Hong Kong)
Phone: +86.21.5187.7337
[email protected]
Languages: Chinese,English
Southwest Asia
(India, Pakistan, Sri Lanka,
Bangladesh, Mongolia)
Phone: +91.99.1008.6221
1
Languages: English, Hindi
Australasia
(Australia, N. Zealand)
Phone: +61.491.095.248
[email protected]
Language: English
Southeast Asia
(Singapore, Indonesia, Philippines,
Thailand, Vietnam, Malaysia,
Myanmar, Cambodia, Laos, Vietnam)
Phone: +60.12.275.3307
[email protected]
Languages: English, Bahasa, Malay
Northeast & Southeast Asia
(Japan, Taiwan)
Phone: +60.12.275.3307
[email protected]
Languages: English, Chinese, Japanese
Korea
Phone: +82.10.7187.2064
[email protected]
Languages: English, Kore
Europe/M. East /Africa
Regional Office
Phone: +33.(0)5.34.36.87.20
[email protected]
Languages: French, English
Regional Tech Support
[email protected]
Middle East, Turkey,
Sub-Saharan Africa
Phone: +971.4.214.6911
[email protected]
Languages: Hindi, English
North Western Europe
(UK, IE, IS, DK, NO, SE)
Phone: +44.(0)7415.864.902
[email protected]
Language: English
Austria, Germany, Switzerland
Phone: +32.474.36.84.51
[email protected]
Languages: French, English, Dutch
France, Benelux, Portugal,
Algeria, Morroco, Tunisia
Phone: +32.474.36.84.51
[email protected]
Languages: French, English, Dutch
Italy, Greece, Israel,
Eastern Europe
Phone: +39.342.8651.595
[email protected]
Latin America
Regional Office
Phone: +52.222.264.1814
[email protected]
Languages: Spanish, English
Regional Tech Support
[email protected]
Argentina, Bolivia, Brazil,
Paraguay, Uruguay
Phone: +55.11.5084.5178
[email protected]
Languages: Portuguese, English
Mexico, Andean, Caribbean,
& Central America (VE, CO, PE, EC)
Phone: +507-6427-48-38
[email protected]
Languages: Spanish, English
North America
Regional Office
Phone: +1.661.716.5100
[email protected]
Languages: English, Spanish
Regional Tech Support
[email protected]
Support and expertise for your projects
ProSoft provides a variety of resources and services for wireless applications from initial system design to site surveys to launch support and configuration support. Tech Support: [email protected]
Contact Us
Copyright ©2022 ProSoft Technology, Inc.
All Rights Reserved. July 2022
Rockwell_2022_EN
References
ProSoft Technology Inc — IIOT connectivity starts with ProSoft
ProSoft Technology Inc — IIOT connectivity starts with ProSoft
Travel time decreases with addition of remote access
Ensure reliable wireless communications with Radiating Cable
IIoT Connectivity: Improve your operation's productivity & efficiency
Utility saves time with managed network
Increase efficiency and decrease downtime with advanced diagnostics
Increase efficiency with Add-On Profiles and Add-On Instructions
Pelican Gathering Increases ROI with Facility Improvements
Conveyance lines updated in a car factory to increase safety and efficiency
How phased modernizations can generate return on investment
Modernizing a brewery with very limited downtime
psft.com/DD7
Contact Form / Contact Us / About Us / Homepage - ProSoft Technology, Inc.
Automating parts delivery in an automotive plant – with some help from AGVs and wireless radios - ProSoft Technology, Inc.
Conveyor Gains Reliable Communication Solution
Ensuring the perfect sample sizes – with help from a Modbus module - ProSoft Technology, Inc.
Freefall ride gets a wireless update
An amusement park modernizes communications
technology.com
ProSoft Technology Inc — IIOT connectivity starts with ProSoft
ProSoft Technology Inc — IIOT connectivity starts with ProSoft
ProSoft Technology Inc — IIOT connectivity starts with ProSoft
Travel time decreases with addition of remote access
Ensure reliable wireless communications with Radiating Cable
IIoT Connectivity: Improve your operation's productivity & efficiency
Utility saves time with managed network
Increase efficiency and decrease downtime with advanced diagnostics
Increase efficiency with Add-On Profiles and Add-On Instructions
Pelican Gathering Increases ROI with Facility Improvements
Conveyance lines updated in a car factory to increase safety and efficiency
How phased modernizations can generate return on investment
Modernizing a brewery with very limited downtime
psft.com/dd7
Contact Form / Contact Us / About Us / Homepage - ProSoft Technology, Inc.



Enhanced modules allow up to 10,000 I/O words



Intelligent routing to ControlLogix® or CompactLogix™ from PLC-5, SLC, MicroLogix™ controllers
Intelligent data routing between DH485 and EtherNet/IP devices
ControlNet Router: Connect existing equipment to new EtherNet/IP -using PanelView Plus terminals – without having to do some major re-cabling. The module also supports Device Level Ring networks or can be used as a two-port Ethernet switch.
DeviceNet Router: Enables data exchanges via EtherNet/IP between DeviceNet devices and your Logix controller or a PanelView Plus terminal. The DeviceNet data can be mapped to a PLC5 type address file; from there, an Ethernet device (such as a PanelView)can either write to or read the data.