BAF552AA160 High Performance Pre filter
Product Information: High Performance Pre-Filter
The High Performance Pre-Filter BAF552AA160 is an optional kit
designed for use with specific Daikin indoor units. It is a filter
that helps to improve indoor air quality by capturing larger
particles such as dust and pet hair before they enter the indoor
unit. This pre-filter is compatible with select Daikin indoor units
in model groups A, B, C, and D. It is important to note that only
the Daikin high performance pre-filter is permitted for replacement
and cannot be used with other filters, chambers, fresh air intake
kits, or air discharge outlet sealing member kit.
Product Usage Instructions: Installation
- Before installation, check the compatibility of the High
Performance Pre-Filter with your indoor unit. Refer to the
installation and operation manual of the indoor unit and the
decoration panel. - Ensure that you have all the following parts included in your
kit: Daikin high performance pre-filter, screw, tie wrap, and
clamp. - Identify the installation site requirements of the unit and do
not install in places with mineral oil or corrosive gas. - Install the pre-filter by following the instructions provided
in the installation manual. - After installation, make sure to replace the filter when the
filter sign is displayed on the remote controller. Contact your
dealer for instructions regarding installation or replacement of
the filter.
Product Usage Instructions: Configuration
To configure the High Performance Pre-Filter, refer to the Field
Setting section in the installation manual. Make sure to refer to
the table of compatible units for proper configuration.
Product Usage Instructions: Disposal
Disposal of the High Performance Pre-Filter should be in
compliance with local regulations. Contact your local waste
management authority for instructions on proper disposal.
Installation manual
High performance pre-filter
BAF552AA160
Installation manual High performance pre-filter
English
Table of contents
Table of contents
a
b
c
d
1×
2×
2×
2×
1 About this document
2
2 About the kit
2
2.1 Components …………………………………………………………………… 2
2.2 Compatibility…………………………………………………………………… 2
3 Installation
2
3.1 Before installation……………………………………………………………. 2
3.2 Installation site requirements of the unit……………………………… 2
3.3 To install the pre-filter………………………………………………………. 2
4 Configuration
3
4.1 Field setting ……………………………………………………………………. 3
5 Disposal
3
1 About this document
Target audience Authorised installers
Documentation set This document is part of a documentation set. The complete set consists of: General safety precautions:
Safety instructions that you must read before installing Format: paper (in the box of the indoor unit) Installation manual: Installation instructions Format: paper (supplied in the kit) Latest revisions of the supplied documentation may be available on the regional Daikin website or via your dealer. The original documentation is written in English. All other languages are translations.
2 About the kit
NOTICE
Read this manual carefully before installation together with all documents from the documentation set, see “1 About this document” 4[ 2].
Be sure to use only the specified components delivered with the option kit when installing.
When the Daikin high performance pre-filter is installed, air volume, performance and operation sound of the indoor unit may be altered.
Only the Daikin high performance pre-filter is permitted for replacement.
Daikin high performance pre-filter CANNOT be used with other filters, chambers, fresh air intake kits or air discharge outlet sealing member kit (for selection of 2 or 3 way air blow).
Replace the filter when the filter sign is displayed on the remote controller.
Contact your dealer for instruction regarding installation or replacement of the filter.
2.1 Components
Make sure you have all the following part included in your kit:
a Daikin high performance pre-filter b Screw c Tie wrap d Clamp
2.2 Compatibility
Combine the Daikin high performance pre-filter with the following indoor units:
21Model group
Group A FCAG35~60
Group B FCAG71
Group C
Group D
FCAG100~140 FXFQ125
FXFQ20~32 FCAHG71~140 FXFQ80+100 FXFA125
FXFA20~32 FXFQ40~63 FXFN50+112 FXFN71
FXFA40~63 FXFA80+100
Refer to this table when performing “4.1 Field setting” 4[ 3]. For a full list of compatible units, refer to the option list.
3 Installation
3.1 Before installation
Check the “2.2 Compatibility” 4[ 2] before installation. Refer to the installation and operation manual of the indoor unit and the decoration panel.
3.2 Installation site requirements of the unit
Do NOT install in places:
With mineral oil, or filled with oil vapour or spray, like in kitchens.
Where corrosive gas like sulphurous gas exists.
Where the humidity is 90% and the temperature is 65°C.
That require a high ceiling mode setting and 2/3 way blow mode setting of the indoor unit.
3.3 To install the pre-filter
Open the suction grille. 1 Slowly lower the suction grille while pressing down on the two knobs.
2 Release the strap of the suction grille from the hook (2 locations). Open the suction grille in 45° angle.
Installation manual
2
BAF552AA160 High performance pre-filter
4P706412-1 2022.12
1
2
4 Configuration
45°
Remove the original air filter from suction grille. 3 Pull the end of the original air filter diagonally down to unhook the air filter from the suction grille. 4 Lift up the air filter and remove the original air filter from the hook on the suction grille.
2 3
1
Attach Daikin high performance pre-filter. 5 Attach 2 clamps (delivered with the kit). Do NOT overtight the screw to avoid damaging the suction grille.
6 Position the Daikin high performance pre-filter with airflow indicator on the high performance pre-filter frame. Point in the same direction of the airflow.
7 Install the Daikin high performance pre-filter securely and fix with tie wraps. The direction of the clamp should match the figure.
13 Follow steps 6~8 to install new filter.
4 Configuration
4.1 Field setting
After installation of the Daikin high performance pre-filter make the following field settings:
Air volume setting
Filter sign setting
INFORMATION
Following setting are only applicable when using the BRC1H52* user interface. When using any other user interface, see the installation manual or service manual of the user interface.
Setting: Air volume setting
Setting(1)
For model group (refer to
M
SW
—
” 21Model group” 4[ 2])
A
13 (23)
0
03
1
02
B
0
02
1
02
C
1
02
D
0
03
Setting: Filter sign setting All models
Setting(1)
M
SW
—
10 (20) 0
01
8 Cut of excess tie wraps.
Re-install the suction grille. 9 Perform steps 1 and 2 in reverse order to re-install the suction grille. Refer to the installation manual provided with the indoor unit and decoration panel.
Finish the installation 10 Perform the field setting, see “4.1 Field setting” 4[ 3].
11 Perform the test run, see the installation manual of the indoor unit.
Replacing the Daikin high performance pre-filter. 12 Cut and remove the tie wraps and remove the Daikin high performance pre-filter.
5 Disposal
Prerequisite: Turn off the indoor unit before removing the pre-filter.
1 While wearing protective glasses, mask and gloves open the suction grille and remove the pre-filter.
2 Put the pre-filter in plastic bag and close tightly.
INFORMATION
Daikin high performance pre-filter CANNOT be renewed by washing.
Daikin high performance pre-filter can be used up to 12 months (2500 h). Pre-filter lifetime may vary depending on the room conditions. In rooms with lot of pollutants (smoke, pets, high traffic areas…) pre-filter may require more frequent changes.
When disposing the pre-filter, follow the local waste separation rules.
(1) Field settings are defined as follows: · M: Mode number First number: for group of units Number between brackets: for individual unit · SW: Setting number · –: Value number
BAF552AA160 High performance pre-filter 4P706412-1 2022.12
Installation manual
3
Verantwortung für Energie und Umwelt
4P706412-1 2022.12
Copyright 2022 Daikin