Instruction Manual
Weather Station
model 02048HD
Questions? Contact Customer Support at
(877) 221-1252 or visit www.AcuRite.com.
SAVE THIS MANUAL FOR FUTURE REFERENCE.
Congratulations on your new AcuRite product. To ensure the best possible product performance, please read this manual in its entirety and retain it for future reference.
Unpacking Instructions
Remove the protective film that is applied to the LCD screen prior to using this product. Locate the tab and peel it off to remove it.
Package Contents
- Display unit with tabletop stand
- Power adapter
- Outdoor sensor
- Instruction Manual
Features & Benefits
OUTDOOR SENSOR
- Integrated Hanger
For easy placement. - Wireless Signal Indicator
Flashes when data is being sent to the display unit. - Battery Compartment
- A-B-C Switch
ID code that must match display’s A-B-C switch to ensure units synchronize. - Battery Compartment Cover
BACK OF DISPLAY UNIT
- Integrated Hang Hole for easy wall mounting.
- Reset Full reset to factory defaults.
- A-B-C Switch ID code that must match tower sensor’s A-B-C switch to ensure units synchronize.
- Battery Compartment
- Plug-in for Power Adapter
- Battery Compartment Cover
FRONT OF DISPLAY UNIT
- “∧” Button
for setup preferences. - ” ” Button for setup preferences.
- “∨ ” Button
for setup preferences. - Momentary Backlight Button
Lights display for 7 seconds (only applicable while on battery power).
DISPLAY UNIT FRONT
- Current Outdoor Temperature
The arrow icon indicates direction temperature is trending. - 12 to 24 Hour Weather Forecast
Self-Calibrating Forecasting pulls data from the outdoor sensor to generate your personal forecast. - Current Indoor Temperature
The arrow icon indicates direction temperature is trending. - Moon Phase
- Display Low Battery Indicator
- AUTO DIM Indicator
(see page 8) - Intelli-Time® Clock
Automatically updates for Daylight Saving Time. - Date
- Current Indoor Humidity
The arrow icon indicates direction humidity is trending. - Humidity Level Indicator
Indicates a high or low indoor humidity level. - Learning Mode Icon
Disappears after weather forecast self-calibration is complete. - Barometric Pressure
The arrow icon indicates direction pressure is trending. - Current Outdoor Humidity
The arrow icon indicates direction humidity is trending. - Heat Index
Displays Heat Index calculation when the temperature is 80°F (27°C) or above. - Sensor Low Battery Indicator
- Outdoor Sensor Signal Strength
- Dew Point
Displays Dew Point calculation when the temperature is 79°F (26°C) or below.
SETUP
Sensor Setup
- Set the A-B-C Switch
The A-B-C switch is located inside the battery compartment. It can be set to A, B or C. However, you must select the same letter choices for both the sensor and the display unit in order for the units to synchronize. - Install or Replace Batteries
AcuRite recommends high-quality alkaline or lithium batteries for the best product performance. Heavy duty or rechargeable batteries are not recommended. The sensor requires lithium batteries in low-temperature conditions. Cold temperatures can cause alkaline batteries to function improperly. Use lithium batteries in the sensor for temperatures below -4ºF / -20ºC.
1. Slide off the battery compartment cover. Take note of the A-B-C switch setting inside the battery compartment.
2. Insert 2 x AA batteries into the battery compartment, as shown. Follow the polarity (+/-) diagram in the battery compartment.
3. Replace the battery cover.
Display Unit Setup
- Set the A-B-C
Switch Locate the A-B-C switch inside the battery compartment. Set the A-B-C switch to A, B or C. You must select the same letter choices for both the display unit and the sensor in order for the units to synchronize. - Plug-in Power Adapter
For the best performance, plug in the power adapter as the main power source for this product. - Install or Replace Backup Batteries (optional)
1. Remove the battery compartment cover.
2. Insert 3 x AA alkaline batteries into the battery compartment, as shown. Follow the polarity (+/-) diagram in the battery compartment.
3. Replace the battery cover.
IMPORTANT: Batteries are a backup power source to preserve records in the event of a power outage. The power adapter is recommended as the primary power source to enjoy the full functionality of this product.
PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE WAY AND IN ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS.
BATTERY SAFETY: Clean the battery contacts and also those of the device prior to battery installation. Remove batteries from equipment that is not to be used for an extended period of time. Follow the polarity (+/-) diagram in the battery compartment. Promptly remove dead batteries from the device. Dispose of used batteries properly. Only batteries of the same or equivalent type as recommended are to be used. DO NOT incinerate used batteries. DO NOT dispose of batteries in fire, as batteries may explode or leak. DO NOT mix old and new batteries or types of batteries (alkaline/standard). DO NOT use rechargeable batteries. DO NOT recharge non-rechargeable batteries. DO NOT short-circuit the supply terminals.
Intelli-Time® Clock
Intelli-Time products are pre-programmed with the correct time and date. All you need to do is select your Time Zone and Daylight Saving Time preferences. The clock will then automatically update for Daylight Saving Time.
Set the Time, Date & Units
Press and HOLD the ” ” button to enter SETUP MODE. Once in setup mode, the preference you are currently setting will blink on the display.
To adjust the currently selected (flashing) item, press and release the ” ∧ ” or ” ∨ ” buttons (press and HOLD to fast adjust).
To save your adjustments, press and release the ” ” button again to adjust the next preference. The preference set order is as follows:
TIME ZONE ( PST MST CST EST AST HAST AKST)
DST* (Daylight Saving Time ON or OFF)
CLOCK HOUR
CLOCK MINUTE
CALENDAR DATE
CALENDAR MONTH
CALENDAR YEAR
TEMPERATURE SCALE (ºF or ºC)
BAROMETRIC PRESSURE SCALE (inHg or hPa)
*If you live in an area that observes daylight saving time, DST should be set to ON, even if it is not currently Daylight Savings Time.
You will automatically exit SETUP MODE if no buttons are pressed for 10
ox seconds. Enter setup mode at any time by pressing the ” ” button.
Backlight Settings
This weather station’s color display features three different lighting settings: High (100%) brightness, Medium (60%) brightness, and Low (30%) brightness.
Using battery power alone, the backlight is available momentarily for 7 seconds by pressing the Momentary Backlight button.
When the display is powered with the power adapter, the backlight remains on at 100% brightness. Press the Momentary Backlight button once to dim to 60% brightness; press again to dim to 30%, press a 3rd time to enter “AUTO DIM” mode. AUTO DIM appears below the time.
AUTO DIM MODE: Automatically adjusts display brightness based on time of day & year. | |
MARCH 11- NOVEMBER 4 | 6:00 a.m. – 9:00 p.m. = 100% brightness |
9:01 p.m. – 5:59 a.m.= 30% brightness | |
NOVEMBER 5 – MARCH 10 | 7:30 a.m. – 7:00 p.m.= 100% brightness |
7:01 p.m. – 7:29 a.m. = 30% brightness |
Placement for Maximum Accuracy
AcuRite sensors are sensitive to surrounding environmental conditions. Proper placement of both the display unit and outdoor sensor is critical to the accuracy and performance of this product.
Display Unit Placement
Place the display unit in a dry area free of dirt and dust. The display unit stands upright for tabletop use or is wall-mountable.
Outdoor Sensor Placement
Sensors must be placed outside to observe outdoor conditions. The sensor is water-resistant and is designed for general outdoor use, however, to extend its life place the sensor in an area protected from direct weather elements.
Hang the sensor using the integrated hang holes or hanger, or by using string (not included) to hang it from a suitable location, like a well-covered tree branch. The best location is 4 to 8 feet above the ground with permanent shade and plenty of fresh air to circulate around the sensor.
Important Placement Guidelines
- To ensure accurate temperature measurement, place units out of direct sunlight and away from any heat sources or vents.
- Display unit and outdoor sensor must be within 330 ft (100 m) of each other.
- To maximize wireless range, place units away from large metallic items, thick walls, metal surfaces, or other objects that may limit wireless communication.
- To prevent wireless interference, place both units at least 3 ft (.9 m) away from electronic devices (TV, computer, microwave, radio, etc.).
Setup is Complete
The sensor will now synchronize with the display unit. It may take a few minutes for synchronization to complete. Please refer to the troubleshooting section of this manual if anything appears to be functioning improperly.
OPERATION
Using the Weather Station
Learning Mode
Self-Calibrating Forecasting uses a unique algorithm to analyze changes in pressure over a time period (called Learning Mode) to determine your altitude. After 14 days, the Learning Mode icon disappears from the display screen. At this point, the self-calibrated pressure is tuned in to your location and the unit is ready for superior weather prediction.
Weather Forecast
AcuRite’s patented Self-Calibrating Forecasting provides your personal forecast of weather conditions for the next 12 to 24 hours by collecting data from the sensor in your backyard. It generates a forecast with pinpoint accuracy personalized for your exact location.
View the complete list of icons at www.AcuRite.com/acurite-icons
Barometric Pressure
Subtle variations in barometric pressure greatly impact the weather. This weather center displays the current pressure and indicates the direction the pressure is trending (FALLING, STEADY, or RISING).
Humidity Level Indicator
The Humidity Level Indicator easily conveys a low or high indoor humidity level for your home and health: Learn more at http://www.acurite.com/humidity-health
High & Low Records
Today’s high and low records are displayed for the indoor and outdoor temperature and humidity. Today’s records automatically clear at 12:00 am-midnight every day. View today’s high or low records by pressing the “∧ ” or “∨ ” buttons. Press and release again to view current readings.
To manually clear all of today’s LOW recorded values, press and release the “∨” button to view low records, then press and HOLD the “∨ ” button for 2 seconds. Dashes will display to confirm you have cleared the LOW records.
To manually clear all of today’s HIGH recorded values, press and release the “∧” button to view high records, then press and HOLD the “∧” button for 2 seconds. Dashes will display to confirm you have cleared the HIGH records.
Troubleshooting
Problem | Possible Solution |
No outdoor sensor retention no bars | If the wireless signal indicator shows no bars: • Relocate the display unit and/or the outdoor sensor. The units must be within 330 ft (100 m) of each other. • Make sure both units are placed at least 3 feet (.9 m) away from electronics that may interfere with the wireless communication (such as TVs, microwaves, computers, etc). • Use standard alkaline batteries (or lithium batteries in the sensor when the temperature is below -4ºF/-20ºC). Do not use heavy-duty or rechargeable batteries. NOTE: It may take up to 20 minutes for the display unit and sensor to synchronize after batteries are replaced. |
Outdoor temperature is flashing or showing dashes | Flashing of the outdoor temperature is generally an indication of wireless interference. 1. Bring both the sensor and display unit indoors and remove at least one battery from each. 2. Make sure the A-B-C switch on both units matches. 3. Reinstall the battery in the outdoor sensor. 4. Reinstall the battery in the display unit. 5. Let the units sit within a couple of feet of each other for about 20 minutes to gain a strong connection. |
Inaccurate forecast | • Weather Forecast icon predicts conditions for the next 12 to 24 hours, not current conditions. • Has the Learning Mode icon disappeared from the display unit? Learning Mode must complete before forecast and pressure will be accurate. • Allow the unit to run continuously for 33 days. Battery removal or resetting the display unit will restart Learning Mode. After 14 days, the forecast should be fairly accurate, however, Learning Mode calibrates for a total of 33 days. |
Inaccurate temperature or humidity | • Make sure both the display unit and sensor are placed out of direct sunlight and away from any heat sources or vents (see page 9). • Make sure both units are positioned away from moisture sources (see page 9). |
Display screen not working | • Check that the batteries are installed correctly. Batteries may need to be replaced. • Reset the display by pressing the reset button, located on the back of the display unit. The date and time will need to be entered after a reset. |
The unit lost power or batteries were changed and the time is not correct | • The Intelli-Time battery needs to be replaced (see page 13). Once the new battery is installed, the time and date will need to be set manually. |
If your AcuRite product does not operate properly after trying the troubleshooting steps, visit www.AcuRite.com or call
(877) 221-1252 for assistance.
Calibration
The indoor/outdoor temperature and humidity readings, and barometric pressure can be calibrated on the display unit to improve accuracy. Calibration can improve accuracy when sensor placement or environmental factors impact the data accuracy.
- To access calibration mode, press AND HOLD the “∧ “, ““, and “∨ ” buttons simultaneously for at least 5 seconds.
- To adjust the currently selected (flashing) item, press and release the “∧ ” or “∨ ” buttons to calibrate the data value higher or lower from the actual reading.
- To save your adjustments, press and release the ” ” button to adjust the next preference. The ” ” icon will remain illuminated next to calibrated values.
The preference set order is as follows:
OUTDOOR TEMPERATURE
OUTDOOR HUMIDITY
INDOOR TEMPERATURE
INDOOR HUMIDITY
BAROMETRIC PRESSURE (must be set to MANUAL mode to calibrate)*
*To change from AUTO to MANUAL pressure mode and vice versa, press
AND HOLD the “ ” button for at least 10 seconds. The display indicates the current pressure mode selected,”AUTO” or “MANUAL”. After 5 seconds of inactivity, the display will save the adjustments and exit calibration mode. Note: Calibrations will be erased if the display is reset or if batteries are removed and the power adapter is unplugged.
Care & Maintenance
Display Unit Care
Clean with a soft, damp cloth. Do not use caustic cleaners or abrasives. Keep away from dust, dirt and moisture. Clean ventilation ports regularly with a gentle puff of air.
Outdoor Sensor Care
Clean with a soft damp cloth. Do not use caustic cleaners or abrasives.
Replace Intelli-Time Clock Battery
Intelli-Time technology is powered by a pre-installed coin-cell battery that stores the time and date settings. The battery has a shelf life of several years. To replace the Intelli-Time battery:
- Locate the coin cell battery compartment door on the back of the display unit. Unscrew and remove the compartment cover.
- Insert 1 x CR2032 coin cell battery into the battery compartment, as shown. Install battery with “+” positive terminal facing OUT.
- Screw in the battery cover.
Specifications
TEMPERATURE RANGE | Outdoor: -40°F to 158°F; -40°C to 70°C |
Indoor: 32°F to 122°F; 0°C to 50°C | |
HUMIDITY RANGE | Outdoor: 1% to 99% RH Indoor: 1% to 99% RH |
WIRELESS RANGE | 330 ft / 100 m depending on home construction materials |
OPERATING FREQUENCY | 433 MHz |
POWER | Display: 5vdc power adapter 3 x AA alkaline batteries (optional) |
Sensor: 2 AA alkaline or lithium batteries | |
DATA REPORTING | Outdoor: 16 second updates |
Indoor: 60-second updates |
FCC Information
This device complies with part 15 of FCC rules. Operation is subject to the following two conditions:
- This device may NOT cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur n a particular installation. If his equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increasetheseparationbetween the equipment and the receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment.
Such modifications could void the user’s authority to operate the equipment.
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:
- This device may not cause interference, and
- This device must accept any interference received, including interference that may cause undesired operation of the device.
Customer Support
AcuRite customer support is committed to providing you with best-in-class service. For assistance, please have the model number of this product available and contact us in any of the following ways:
(877) 221-1252
Visit us at www.AcuRite.com
► Installation Videos
► Instruction Manuals
► Replacement Parts
► Register your Product
► Support User Forum
► Submit Feedback & Ideas
Limited 1-Year Warranty
At AcuRite, we proudly uphold our commitment to quality technology. Chaney Instrument Co. warrants that all products it manufactures to be of good material and workmanship and to be free of defects when properly installed and operated for a period of one year from the date of purchase.
We recommend that you visit us at
www.AcuRite.com for the fastest way to register your product. However, product registration does not eliminate the need to retain your
original proof of purchase in order to obtain warranty benefits.
Chaney Instrument Co. warrants that all products it manufactures to be of good material and workmanship and to be free of defects when properly installed and operated for a period of one year from the date of purchase. Remedy for breach of this warranty is limited to repair or replacement of the defective item(s). Any product which, under normal use and service, is proven to breach the warranty contained herein within ONE YEAR from the date of sale will, upon examination by Chaney, and at its sole option, be repaired or replaced by Chaney.
Transportation costs and charges for returned goods shall be paid for by the purchaser. Chaney hereby disclaims all responsibility for such transportation costs and charges. This warranty will not be breached, and Chaney will give no credit for products it manufactures which have received normal wear and tear, been damaged (including by acts of nature), tampered, abused, improperly installed, damaged in shipping, or repaired or altered by others than authorized representatives of Chaney.
The above-described warranty is expressly in lieu of all other warranties, express or implied, and all other warranties are hereby expressly disclaimed, including without limitation the implied warranty of merchantability and the implied warranty of fitness for a particular purpose. Chaney expressly disclaims all liability for special, consequential, or incidental damages, whether arising in tort or by contract from any breach of this warranty. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Chaney further disclaims all liability from personal injury relating to its products to the extent
permitted by law. By acceptance of any of Chaney’s products, the purchaser assumes all liability for the consequences arising from their use or misuse. No person, firm, or corporation is authorized to assume for Chaney any other liability in connection with the sale of its products. Furthermore, no person, firm, or corporation is authorized to modify or waive the terms of this paragraph, and the preceding paragraph, unless done in writing and signed by a duly authorized agent of Chaney. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
For in-warranty claims: Chaney Instrument Co.
965 Wells St., Lake Geneva, WI 53147
It’s more than accurate, it’s
AcuRite offers an extensive assortment of precision instruments, designed to provide you with information you can depend on to
Plan your day with confidence™.
www.AcuRite.com
© Chaney Instrument Co. All rights reserved. AcuRite is a registered trademark of the Chaney Instrument Co., Lake Geneva, WI 53147. All other trademarks and copyrights are the property of their respective owners. AcuRite uses patented technology.
Visit www.AcuRite.com/patents for details.
Printed in China
02048HD INST 081215
Documents / Resources
ACURITE 02048HD Weather Station [pdf] Instruction Manual 02048HD, Weather Station |