Quoizel Baw3122pk Lamps And Lighting Barlow Fan Light Installation Guide

BAW3122PK Lamps and Lighting Barlow Fan Light

Product Information

The BAW3122PK and BAW3122WS are ceiling fans manufactured by
Quoizel. The fans come with a remote control and four LED bulbs.
The fans are designed for ceilings up to 11 feet high and can
support a weight of up to 50 lbs (22.72 kg). Longer downrods are
included for angled ceilings or ceilings 12 feet or higher. The
fans cannot be used for ceilings with an angle greater than 10
degrees.

Product Usage Instructions

Warnings and Cautions

Before installing the fan, read and save the instructions
provided. Use the appropriate tools when removing or installing
parts. For further assistance, contact Quoizel Customer Care at
1-800-645-3184 (9:00 am – 5:00 pm EST), or visit the Quoizel
website at www.quoizel.com.

Package Contents

The package contains the following:

  • Rod Assembly x1
  • 12L Rod x1
  • Receiver x1
  • Ceiling Canopy x1
  • Ceiling D Canopy Cap x1
  • Fan Blade x1
  • Blade G Assembly Nut x1
  • LED Bulb x4
  • Fixture Body x1
  • Glass Panel x4
  • Parts Bag 1:
    • Lock Washer x4
    • Spring Washer x4
    • Flat Washer x4
    • Wire Connector x7 (1 replacement connector included)
    • Screw x2
    • Mechanical Screw x2
    • Hanger Frame x1
  • Parts Bag 2:
    • Spring Washer x1
    • Flat Washer x1
    • Screw x1
    • Wall Anchor x1
    • Fastener with LL Set Screw x1
  • Parts Bag 3:
    • 9V Battery x1
    • Remote Control MM Transmitter x1
    • Wall Bracket OO x1
    • Screw x2

Installation Guide

Step 1: Install Glass Panels

Assemble the glass panels so that the side edge is hidden behind
the vertical bars.

Step 2: Install Hanger Frame

Secure the hanger frame to the support structure using wood
screws and drill a 9/64 pilot hole. If the hanger frame is being
secured to an existing ceiling fan-rated outlet box, use machine
screws instead of wood screws.

Step 3: Choose Rod

Select the standard downrod for ceilings up to 11 feet high. For
angled ceilings or ceilings 12 feet or higher, use the longer
downrod provided.

Step 4: Install Rod to Fixture Body

Remove the pin, install the ceiling canopy and ceiling canopy
cap, remove the set screws on the fixture body, install the set
screws, install the pin, and finally install the rod.

Step 5: Install Rod to Hanger Frame

Attach the rod to the hanger frame.

Step 6: Install Safety Cable

For concrete ceilings, drill a 5/16 pilot hole and install the
safety cable.

Step 7: Wiring

Connect the white wire from the outlet box to the white wire
from the receiver with the label N. Connect the black wire from the
outlet box to the black wire from the receiver with the label AC L.
Connect the black (or red) wire from the outlet box to the black
wire from the receiver with the label AC N. Connect the green
ground screw on the crossbar to the bare or green ground wire from
the outlet box.

Step 8: Place Controller to Hanger Frame

Connect the white wire from the receiver with the label N to the
white wire from the fixture identified with the label N. Connect
the black wire from the receiver with the label MOTOR L to the
black wire from the fixture identified with the label MOTOR L.
Connect the blue wire from the receiver with the label LIGHT L to
the blue wire from the fixture identified with the label LIGHT L.
Connect the ground wire from fixture to ground wire from hanger
frame.

Step 9: Install Ceiling Canopy and Cap

Install the ceiling canopy and cap.

Step 10: Install Fan Blade

Remove and attach fan blades as necessary and install blade
assembly nut.

Step 11: Install Bulbs

Install four correct bulbs referring to fixture markings and/or
labels for maximum wattage.

INSTALLATION GUIDE FOR BAW3122PK and BAW3122WS

WARNINGS AND CAUTIONS

Released Date: 2022-04-08

READ AND SAVE THESE INSTRUCTIONS
Please read and understand this entire manual before attempting to assemble, install or operate the product. WARNING · RISK OF ELECTRIC SHOCK – Before beginning installation, turn off electricity at the circuit breaker box or the main fuse box. · RISK OF FIRE – Use bulbs specified by the markings and/or labels on the fixture. · RISK OF PERSONAL INJURY – DO NOT bend the blades when installing the fan, or cleaning the fan. Do not insert foreign objects in between
rotating fan blades. · RISK OF FIRE, ELECTRIC SHOCK, OR PERSONAL INJURY – mount to outlet box marked (acceptable for fan support of 22.7kg(50lbs) or less)
and use mounting screws provided with the outlet box. · All set screws must be checked, and re-tightened where necessary, before installation. · After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one
side of the outlet box and the ungrounded conductor on the other side of the outlet box. · Suitable for use with solid-state speed controls. · use only with light kits marked suitable for use in damp locations. · This unit weighs 8.1 kg (17.82 lbs). CAUTION · For your safety, read instructions completely before beginning installation. · If in doubt about electrical installation, consult a licensed electrician. · Disconnect fixture from the power source before replacing bulbs or cleaning. Make sure the bulbs are given sufficient time to cool be before
removing. TOOLS REQUIRED

CARE AND MAINTENANCE
· Wipe clean using soft, dry cloth or static duster. Always avoid using harsh chemicals and abrasives to clean fixture as they may damage the finish.
If you need further assistance call Quoizel Customer Care at 1-800-645-3184 (9:00am – 5:00pm EST), or visit us on-line at www.quoizel.com.
PACKAGE CONTENTS

A

Rod Assembly x1

B

12″L Rod x1

E

Receiver x 1

C

Ceiling Canopy x1

Ceiling D Canopy Cap
x1

F

Fan Blade x1

Blade G Assembly Nut
x1

H

LED Bulb x4

– 1 of 6 –

I

Fixture Body x1

J

Glass Panel x4

PACKAGE CONTENTS (PARTS BAG 1)

AA

Lock Washer x4

BB

Spring Washer x4

CC

Flat Washer x4

Wire Connector

DD

[1pc replacement connector included]

x7

EE

Screw x2

FF

Mechanical Screw x2

GG

Hanger Frame x1

PACKAGE CONTENTS (PARTS BAG 2)

HH

Spring Washer x1

II

Flat Washer x1

KK

Screw x1

JJ

Wall Anchor x1

Fastener with LL Set Screw
x1

INSTALLATION
1 Install Glass Panels

PACKAGE CONTENTS (PARTS BAG 3)

NN

9V Battery x1

Remote Control MM Transmitter
x1

Wall Bracket OO x 1

PP

Screw x2

2 Install Hanger Frame
Outlet box

9/64″ pilot hole

CEILING

Vertical Bar

Side Edge

Use machine screws when securing to existing ceiling fan-rated outlet box.
that supports of 50 lbs (22.72 kg) or less.

Use wood screws When securing to support structure with approved electrical outlet box. Drill
9/64″ pilot holes.

* The side edge of the glass panel must be hidden behind of the vertical bars after assembly.
– 2 of 6 –

This fan cannot be used for the ceiling which angle is greater
than 10 degree.
For angled ceilings, point opening toward peak.

INSTALLATION
3 Choose Rod
OPTION 1
Standard Downrod (Included Pre-assembled) for ceilings 11 Feet high

SKIP TO NEXT STEP

1

2

3

Steps 1-3 to remove standard downrod

OPTION 2
Longer Downrod (Included) for angled ceilings or ceilings 12 Feet or higher

4

Steps 4-6 to assemble longer downrod

6

5

4 Install Rod to Fixture Body

1

2

3

Steps 1-2 to remove pin

Install ceiling canopy & ceiling canopy cap

4
Remove set screws on fixture body

Install set screws 7

Install pin 6

Install rod 5

– 3 of 6 –

INSTALLATION
5 Install Rod to Hanger Frame

6 Install Safety Cable

5/16″ pilot hole
Optional: for concrete ceiling

Pick the fan up by the down rod only. Place the downrod ball into the slot in the ceiling bracket.

7 Wiring

White wire from outlet box

Black wire from receiver with the Label “AC N”

Black (or Red) wire from outlet box

Black wire from receiver with the Label “AC L”

Green Ground Screw on the Crossbar
Bare, or Green Ground wire
from outlet box

8 Place Controller to Hanger Frame

ON ON DIP 1234

White Wire from receiver with the Label “N”

White wire from fixture identified with the Label “N”

Black wire from receiver with the Label “MOTOR L”
Blue wire from receiver with the Label “LIGHT L”

Black wire from fixture identified with the Label “MOTOR L”
Blue wire from fixture identified with the Label “LIGHT L”

Ground wire from Fixture Ground wire from Hanger Frame
9 Install Ceiling Canopy and Cap

– 4 of 6 –

INSTALLATION
10 Install Fan Blade
1 Remove pin

2 Attach fan blade

3 Install pin

4 Install blade assembly nut

11 Install Bulbs

Install four correct bulbs referring to fixture markings and/or labels for maximum wattage.
Recommended Bulb Type (included):
8W MAX

12 Install Wall Bracket
WALL

BULB BASE TYPE BULB TYPE Medium (E26) TYPE S LED

13 Install Battery to Remote Control Transmitter

1 Remove back cover

2 Match the codes on receiver and remote

Receiver

ON DIP 1234

Remove the rubber stopper from the receiver. Then the code must be the same for both receiver and remote. Place the previously removed rubber stopper back in the receiver.

Remote

Antenna

ON DIP 1234

OPERATION:
1. Light button : Press it to turn on the lights. Press it again to turn off the lights. Long press it, the bulbs will be dimmable.
2. HI, MED, LOW, OFF buttons: To adjust fan speed.

1 2
Battery 6F22 9V
Install battery and back cover 4
– 5 of 6 –

Battery 6F22 9V
Connect battery 3

ADDITIONAL FUNCTIONS
14 Reverse Fan Blade (Optional)

Season Summer Winter

Reverse Switch Information

Rotation Direction Switch Position

Counterclockwise Clockwise

Left Right

Reversing Switch

Note: 1. If airflow is desired in the opposite direction, turn the
fan off and wait for the blades to stop turning. 2. Push the reverse switch to Left or Right completely.

Your installation is now complete! Restore electricity and save this sheet for future reference.

– 6 of 6 –

References