Product Information
The Aria Ceiling Hood is a cooker hood designed for home use. It
is available in two colors: white (VP-CH93WHTSS.2 and VP-CH93WHT.2)
and black (VP-CH93BLKSS.2 and VP-CH93BLK.2). This product is
compliant with the following European Directives: 2014/30/EU (EMC),
2014/35/EU (LVD), 2011/65/EU (RoHS), and 2009/125/EC (ErP).
Product Usage Instructions
Safety Instructions
- Read the instruction manual carefully before using the cooker
hood and keep it in a safe place. - Ensure that the voltage and frequency indicated on the cooker
hood match those in your home. - Installation work should be carried out by a qualified
electrician or competent person. - Do not allow children to operate the cooker hood.
- The cooker hood is intended for home use only, not for
barbecues, roast shops, or commercial purposes. - Regularly clean the cooker hood and its filter mesh to maintain
its performance. - Before cleaning, switch off the power at the main supply to
avoid the danger of burning. - Do not place the cooker hood near an open fire.
- If there is any fault with the appliance, contact the service
department for assistance. - This appliance can be used by children aged 8 years and above
with supervision.
Important Hints on Installation
- Do not discharge the air into a flue used for exhausting fumes
from appliances burning gas or other fuels. - Ensure compliance with regulations concerning the discharge of
air.
Important Information about Extraction
WARNING: Risk of poisoning from exhaust gases
sucked back. Never operate the device in extraction mode
simultaneously with an open flue appliance when there is not
adequate airflow guaranteed.
In extraction mode, indoor air is removed from the kitchen and
adjacent rooms, creating a vacuum. This can lead to toxic gases
from the chimney or extraction flue being sucked back into living
spaces. Avoid using the cooker hood in extraction mode if there is
inadequate airflow or an open flue appliance operating
simultaneously.
Aria Ceiling Hood Installation And User’s Manual
VP-CH93WHTSS.2 VP-CH93BLKSS.2 VP-CH93WHT.2 VP-CH93BLK.2
Aria Ceiling Hood Fitting Instructions and Operation
Aria Ceiling Hood Fitting Instructions and Operation
Dear Customer,
Congratulations on purchasing this equipment. Please read this manual carefully and take care of the following hints to avoid damages. Any failure caused by ignoring the items and cautions mentioned in the instruction manual is not covered by our warranty and any liability.
Content
Contents
3
Safety Instructions
4
Installation
6
Recirculation Mode
8
Changing the Filter
8
Operation
9
Remote Control
10
Technical Data
11
Trouble shooting
12
Cleaning And Care
13
Hints On Disposal
13
Declaration of conformity
This product is conform to the following European Directives:
2014/30/EU (EMC) 2014/35/EU (LVD) 2011/65/EU (RoHS) 2009/125/EC (ErP)
Aria Ceiling Hood Fitting Instructions and Operation
Safety instructions
Thank you for purchasing this cooker hood. Please read the instruction manual carefully before you use the cooker hood, and keep it in a safe place.
The installation work must be carried out by a qualified electrician or competent person. Before you use the cooker hood, make sure that the voltage (V) and the frequency (Hz) indicated on the cooker hood are exactly the same as the voltage
(V) and the frequency (Hz) in your home. The manufacturer and the agent will not bear any responsibility for the damage
caused by inappropriate installation and usage. Never let children operate the cooker hood. The cooker hood is for home use only. It is not suitable for barbecues, Roast
shopand commercial purposes. The cooker hood and its filter mesh should be cleaned regularly in order to
keep it in good working order. Before cleaning, switch the power off at the main supply. Clean the cooker hood according to the instruction manual and keep the
cookerhood from the danger of burning. Prohibit putting the cooker hood by fire. If there is any fault with the appliance, please call the service department to
request a service engineer. This appliance can be used by children aged from 8 years and above and
persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. The instructions shall state the substance of the following: there shall be adequate ventilation of the room when the range hood is used at the same time as appliances burning gas or other fuels (not applicable to appliances that only discharge the air back into the room). Do not flambé under the range hood. Accessible parts may become hot when used withcookingappliances.
Important Hints on Installation
The air must not be discharged into a flue that is used for exhausting fumes from appliances burning gas or other fuels (not applicable to appliances that only discharge the air back into the room).
Regulations concerning the discharge of air have to be fulfilled.
Aria Ceiling Hood Fitting Instructions and Operation
Importan about extractio
WARNING Risk of poisoning from exhaust gases sucked back. Never operate the device in extraction mode simultaneously with an open flue appliance when there is not adequate airflow guaranteed.
Open flue combustion equipment (for example, gas, oil, wood or coal-fired heaters, tankless water heaters, water heaters) pulls combustion air from the room and run it through an exhaust pipe or chimney to the outside. In the extraction mode, indoor air is removed from the kitchen and the adjacent rooms – without sufficient air intake this creates a vacuum. Toxic gases from the chimney or extraction flue can thereby be sucked back into the living spaces.
Always ensure that a sufficient supply of fresh air is guaranteed and that the air can circulate.
An air supply / extractor box alone does not ensure compliance with the limit value.
Safe operation is only possible when the negative pressure in the room where the appliance is located does not exceed 4 Pa (0.04 mbar). This can be achieved when the air required for combustion can flow through openings that are not closable, For example in doors, windows, in conjunction with an air supply/ extractor box or through other technical measures. In any case, consult a qualified chimney sweep who can assess the entire ventilation of your house and propose appropriate measures for adequate ventilation.
If the hood is used exclusively in the recirculation mode, unrestricted operation is possible.
WARNING Fire hazard from flying sparks. Only install equipment on a fireplace for solid fuels (for example, wood or coal), if a closed, non-removable cover is available.
Aria Ceiling Hood Fitting Instructions and Operation
Installation
Preparation If you have an outlet to the outside, your cooker hood can be connected as below picture by means of an extraction duct (enamel, aluminum, flexible pipe or inflammable material with an interior diameter of 150mm)
Before installation, turn the unit off and unplug it from the outlet.
The cooker hood should be placed at a distance of 65 – 150cm above the cooking plane for best effect.
Installation (Vent outside) Note: ‘When the range hood and appliance supplied with energy other than electricity are simultaneously in operation, the negative pressure in the room must be not exceed 4 Pa (4 x 10·5 Bar). Dimensions
Aria Ceiling Hood Fitting Instructions and Operation
Ceiling Installation
Saw a hole in the ceiling according tothe dimensions of the extractor hood.
Ceiling
Slide the extractor hood into the opening.
Brackets
Hood Push the extractor hood upwards until the brackets engage in the false ceiling. If youdo not engage, use a screwdriver to pierce the four holes in the lower corners of the hood.
The brackets should be adjusted so that the lower edge of the extractor hood is flush with the ceiling. Screw four screws through the four holes in the lower corners of the hood.
Note: The ventilation pipe must be installed after adjusting the extractor hood.
When mounting a non-return valve, it must be ensured that the valve can be opened freely. If the valve cannot be opened freely, it can reduce the suction power and increase the noise from the extractor hood.
Note: The hood uses 220mm x 90mm rectangular ducting. Please ensure that you use this or 150mm round. If reducing the size, the minimum size is 125mm round. Using anything smaller will invalidate the warranty.
Aria Ceiling Hood Fitting Instructions and Operation
Recirculation Mode
If the hood is to be installed as a recirculation hood, the air needs to return to the kitchen once cleaned by the charcoal filter. The vent back into the kitchen should be 1.5m minimum from the hood to ensure adequate airflow. Follow the previous installation instructions for mounting the hood with the addition of the ducting to carry the air to the ceiling vent.
Adding/Changing the carbon filter
Open up the hinged door on the hood. Remove the grease filters. Plug the activated carbon filter into the unit and turn it in
clockwise direction. Repeat the same on the other side. Make sure the filter is
securely locked. When activated carbon filter attached, the suction power will be lower. Replace the filter every 3-4 months for optimum operation. If the extractor hood is used for recirculation and there is no external ventilation (exhaust air), it is important that the ventilation is not blocked or impaired, as this can damage the extractor hood, reduce capacity and increase noise. In addition, no non-return valve can be installed in recirculation mode.
Aria Ceiling Hood Fitting Instructions and Operation
Operation
Control Panel and Button Functions
Switch the engine on and off. The motor runs at low speed. The motor runs at medium speed. The motor runs at high speed. Switch the light on and off.
Setting the Lighting Colour
In standby mode, press and hold the LIGHT button to adjust the illumination color. Use the button (3) to adjust one of the following light colors. The lights will show the corresponding number (L1-L9):
Display L1 L2 L3 L4 L5
Colour White Red Green Blue Yellow
Display L6 L7 L8 L9
Colour Purple Orange Cyan Yellow-green
Aria Ceiling Hood Fitting Instructions and Operation
Remote Control
1
Press button (1) to switch the motor on or off.
2
Press button (2) to decrease power or speed.
3
Press button (3) to increase power or speed.
4
Press the button (4) to turn the light on or off.
Press the key (5) when the power is
on to activate the timer mode. The
5
pre-set time for the timer is 5 minutes. When the timer has
expired, the cooker hood will
automatically turn off.
To calibrate the remote control
In standby mode, long press the on/off button on the hood panel for 3 seconds till it flashes, then immediately press the on/off button on the remote control to complete
If the calibration was successful, an acoustic signal sounds. If the calibration was not successful, the cooker hood switches to
standby mode.
Aria Ceiling Hood Fitting Instructions and Operation
TECHNICAL DATA Type Material Installation width mm Ceiling Installation Control Type Recirculation Annual energy consumption (AEChood) Energy efficiency category Fluid dynamical efficiency (FDEhood) Fluid dynamical efficiency category Lighting efficiency (LEhood) Lighting efficiency category Grease separation Grease separation category Air flow Maximum air flow Qmax Airflow at boost setting A-rated noise emission Power consumption off (Po) Power consumption standby (Ps) Power Consumption lighting system (W) Connected load Illuminant Power consumption per illuminant unit Voltage / frequency Height Adjustment in mm Grease filter / material / dishwasher safe Carbon filter Installation material Instruction manual Dimension appliance HxWxD mm Weight net / gross kg
Ceiling Cooker Hood Stainless Steel & Glass
900
Touch & Remote Optional 51.4 kW/h D 9.7 E 4.0 lux/W G 69.1% D
317.2m³/hr 411.1m³/hr 411.1m³/h N/A 54dB 59dB 0.4W 0.38W 10.0W 85W / LED 2 * 5W
220 240 V AC /50Hz 200
2 / aluminium / Optional
207 x 320 x 900 15.3 / 17.9
Aria Ceiling Hood Fitting Instructions and Operation
Troubleshooting
Fault Light on, but fan does not work Both light and fan do not work
Serious vibration of the unit
Suction performance not good
Cause The fan blade is jammed. The motor is damaged.
Light bulb burned out.
Power cord loose
The fan blade is damaged. The fan motor is not fixed tightly. The unit is not hung properly on the bracket.
Too long distance between the unit and the cooking plane
Solution
Switch of the unit and Repair by qualified service personnel only. Replace the bulb with correct rating.
Plugin to the power supply again.
Switch of the unit and Repair by qualified service personnel only.
Takedown the unit and check whether the bracket is in proper location. Readjust the distance to 65 – 150cm
Aria Ceiling Hood Fitting Instructions and Operation
Cleaning and Care
Monthly Cleaning for Grease Filter Clean the filter every month can prevent any risk of fire. The filter collects grease, smoke and dust, so the filter is directly affecting the efficiency of the cooker hood. If not cleaned, the grease residue (potential flammable) will saturate on the filter. Clean it with household cleaning detergent.
Hints on disposal
According to the European waste regulation 2012/19/EU this symbol on the product or on its packaging indicates that this
product may not be treated as household waste. Instead it should be taken to the appropriate collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. For more detailed information about recycling of this product, please contact your local council or your household waste disposal service.