SCHLAGE Deadbolt with Alarm BE469 User Guide - Manualsee

SCHLAGE Deadbolt with Alarm BE469 User Guide

SCHLAGE - LOGO

SCHLAGE Deadbolt with Alarm BE469 - ICON

Touchscreen
Deadbolt with Alarm
Model BE469 User’s Guide

SCHLAGE Deadbolt with Alarm BE469 -

Please Keep This Guide
SCHLAGE Deadbolt with Alarm BE469 - syambol
You will need these instructions for future reference.

Need Help?
Please call customer support before returning the product to the store.
Toll-Free Calling From:
U.S.A.: (888) 805-9837
Canada: (800) 997-4734
Mexico: 018005067866
Visit our website for videos, FAQs, and more: answers.schlage.com

Warranty and FCC/IC Statements

Register Your Product

Document your purchase and register your warranty at RegisterMySchlage.com, or use the included registration card.

Lifetime Limited Mechanical and Finish Warranty and 1-Year Limited Electronics Warranty
Subject to the terms and conditions of the warranty, Schlage extends a lifetime limited mechanical and finishes warranty and a one-year limited electronics warranty to the original consumer user (“Original User”) of our Schlage brand product (“Product”) against defects in material and workmanship, as long as the Original User occupies the residential premises upon which the Product was originally installed. See answers.schlage.com for specific warranty details and limitations, or contact Schlage Customer Service at (888) 805-9837 in the U.S. and Canada or (800) 5067866 in Mexico for assistance.

FCC Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and receiver.
– Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
– Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules.

lock Setup

Follow these steps to get your lock set up and ready to use. If you would like to use a home automation system to enable remote control of the lock, refer to Enrolling on a Z-Wave
Network on page 13.

  1. Decide what length you want the User Codes for the lock to be.
    You can set User Codes to be from 4 – 8 digits in length. The default length is 4 digits. All User
    Codes must be the same length. Any time you change the User Code length, all current User
    Codes will be deleted from the lock.
    • See Change User Code Length on page 7.
  2. Add/Delete User Codes.
    The lock comes preset with two unique User Codes. You can either use these codes or remove them and program your own codes.
    • See Add User Code and Delete User Code on page 7.
  3. Decide if you want to use the Auto-Lock feature or not.
    When the Auto-Lock feature is enabled, the lock will automatically relock itself 30 seconds after being unlocked.
    • See Enable/Disable Auto-Lock on page 7.
  4. Turn on the alarm and decide which model you want to use.
    The alarm is turned off by default. If you want to use the alarm, you’ll need to turn it on and decide on a mode.
    • See Programming the Alarm on page 8.

PLEASE KEEP THIS GUIDE

This guide contains important information about your lock!
• Default User Codes and Programming Code are located on the sticker on the back of this guide! You will need these if you ever need to reset your lock back to factory default settings!
• The sticker also contains your serial number, which may be needed for warranty and customer service support.
• Instructions for adding and deleting User Codes, changing the lock behavior, troubleshooting, customer service, and more are explained in this guide!

Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

RF Exposure

To comply with FCC/IC RF exposure requirements for mobile transmitting devices, this transmitter should only be used or installed at locations where there is at least a 20 cm separation distance between the antenna and all persons.
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.
This device complies with Industry Canada License-exempt RSS standard(s). Operation is subject to the following two conditions: 1) this device may not cause interference, and 2) this device must accept any interference, including interference that may cause undesired operation of the device.

LOCK PARTS

SCHLAGE Deadbolt with Alarm BE469 - FIG 1

Inside Schlage Button• Located on the inside of the door.
• Has three distinct lights.
• Used to program the alarm. See Programming the Alarm on page 8.
• Does not lock or unlock the door.
Thumbturn• Used to lock and unlock manually from the inside.
Outside Schlage Button• Located on the outside of the door.
• The first button you will press when entering a User Code and in the programming process.
• Press to exit programming mode immediately.
Touchscreen• Remains unlit until the Outside Schlage Button is pressed.
• Located on the outside of the door.
• Used to enter codes for programming and unlocking.
Cylinder• Used to unlock only in emergency situations. See Emergency Key Override on page 12.
Alarm Speaker• Sounds alarms based on the chosen settings. See Programming the Alarm on page 8.
Bolt• Automatically extends and retracts when the touchscreen is used.
• Manually extends and retracts when the thumb turn is rotated.

REPLACING THE BATTERIES

  • Replace the batteries in your lock at the same time each year that you test and replace the batteries in your smoke alarms. This will ensure continued reliable operation.
  • Use four high-quality alkaline AA batteries for replacement. Lithium batteries may cause undesirable operations.

ELECTROSTATIC DISCHARGE
SCHLAGE Deadbolt with Alarm BE469 - ICON 1WARNING!
DO NOT TOUCH the circuit board! You may damage the lock.

  1. Remove the inside cover.SCHLAGE Deadbolt with Alarm BE469 - FIG 2
  2. Unsnap the battery connector, remove the battery tray and replace the batteries.
    SCHLAGE Deadbolt with Alarm BE469 - FIG 3
  3. Replace the battery tray with the batteries facing the door. Snap the battery connector to the tray and replace the cover.
    SCHLAGE Deadbolt with Alarm BE469 - FIG 4

LOCKING AND UNLOCKING

If you make a mistake while entering a User Code, press the Outside Schlage Button and then start again.

Locking from the Outside

  1. SCHLAGE Deadbolt with Alarm BE469 - FIG 5Press the Outside Schlage Button.
  2. The lock will lock. The green checkmark will light once.

If the bolt cannot fully extend, the red X will light and a tone will sound. The door may remain unlocked!
If the Lock & Leave feature is disabled, a valid User Code must be entered to lock the door. See Enable/Disable Lock & Leave on page 7.

Locking from the Inside

SCHLAGE Deadbolt with Alarm BE469 - FIG 6

Rotate the Inside Thumbturn.
The Inside Schlage Button will not lock the deadbolt. It is used to program and control the alarm. See Programming the Alarm on page 8.

Unlocking from the Outside

SCHLAGE Deadbolt with Alarm BE469 - FIG 7

  1. Press the Outside Schlage Button.
  2. Enter a valid User Code.
  3. The green success checkmark will flash twice and one beep will sound. The deadbolt will unlock.
    If the red error X lights, the User Code was not valid.

Unlocking from the Inside

SCHLAGE Deadbolt with Alarm BE469 - FIG 8Rotate the Inside Thumbturn.
The Inside Schlage Button will not unlock the deadbolt. It is used to program and control the alarm. See Programming the Alarm on page 8.

CLEANING THE LOCK

In order to properly clean the touchscreen from a build-up of dirt, oils, or other contaminants; you should use mild dish soap with warm water and follow the general rules below:

  • Do rinse the touchscreen with warm water prior to the cleaning process.
  • Do follow the application of soap with a damp, lukewarm cloth
  • Don’t use abrasives, high alkaline cleaners, or gasoline
  • Don’t leave cleaners on the touchscreen for long periods, wash immediately.
  • Don’t apply cleaners in direct sunlight or at elevated temperatures.
  • Don’t use scrapers, squeegees, or razors.
    The bolt itself can be cleaned, using mild dish soap and warm water. This can help improve decreased performance.

PROGRAMMING THE TOUCHSCREEN

SCHLAGE Deadbolt with Alarm BE469 - FIG 9

Tips for Successful Programming

  • Watch the video before you begin! Browse to answers.schlage.com and watch User and Alarm Programming For Touchscreen Deadbolt.
  • The lock comes preset with a unique default Programming Code and two unique Default User Codes. Use these codes to
    operate your lock or change them using the instructions in this guide.
  • Default Codes are located on the back of the Alarm Assembly, and on the back of this guide.
  • If you would like to use a home automation system to enable remote control of the lock, refer to Enrolling on a Z-Wave Network on page 13.

Programming Descriptions

Add User CodeUser Codes unlock the deadbolt. Can be 4 – 8 digits long. All codes must be the same length. See Change User Code Length on page 7.
Delete User CodeRemoves one User Code at a time.
Change Programming CodeThe Programming Code is used to put the lock into Programming Mode. It is 6 digits long.
Enable Vacation ModePrevents all user codes from unlocking the deadbolt. Enable extra security while you are away for an extended period of time.
Disable Vacation ModeReturns lock to normal operation.
Enable/Disable BeeperThe beeper can be turned off if desired. Beeps will still sound during programming.
Delete ALL User CodesRemoves ALL User Codes from the lock.
Enable/Disable Lock & LeaveWhen enabled: Press the Outside Schlage Button to lock the deadbolt. (Default setting). When disabled: Press the Outside Schlage Button and then enter a user code to lock the deadbolt.
Change User Code LengthUser Codes can be 4 – 8 digits in length. Default is 4 digits. Changing the User Code length will delete all existing User Codes!
Enable/Disable Auto-LockWhen enabled, the lock will automatically relock 30 seconds after unlocking. (Disabled by default.)
Temporarily Disable Auto-LockAuto-Lock must already be enabled. While the deadbolt is locked, press the Outside Schlage Button and then enter a 4-8 digit User Code to unlock the deadbolt. Within 5 seconds, manually lock and unlock the deadbolt using the thumbturn.
Restore Auto-LockLock the deadbolt using the thumbturn.

Programming Procedures

Determine how long you want your User Codes to be BEFORE adding any User Codes. If you change the User Code length, all existing User Codes will be deleted!

FOR USING A STANDALONE UNIT

• Programming Mode will automatically time out after 30 seconds of inactivity.

  1. Open the door and extend the deadbolt before beginning.
  2. If you make a mistake, press the Outside Schlage Button to leave Programming Mode, and then start over

WRITE YOUR PROGRAMMING CODE HERE FOR EASY ACCESS

PROGRAMMING THE ALARM

  1. Powering the Alarm
    The alarm is turned off by default. After installation, you’ll need to turn on your alarm.
    • Program the alarm using the Inside Schlage Button, shown below.
    • Not sure your alarm is turned on? Simply press and release the Inside Schlage Button once. It will beep and light up to confirm it is activated. If it does not, try turning the alarm on again, and check the batteries.
    • Watch the video before you begin! Browse to answers.schlage.com and watch User and Alarm Programming For Touchscreen Deadbolt.
    SCHLAGE Deadbolt with Alarm BE469 - FIG 10•  If you want to silence an alarm early, press and hold the Inside Schlage Button until the alarm sound stops.
    • Want to hear what the alarm sounds like in Activity or Forced Entry mode? Enter an incorrect code four times and the alarm will sound.
  2. Alarm setting Descriptions
    Decide which alarm setting is best for you.

    MODE

    DESCRIPTIONLIGHTS

    SOUNDS

    Activity
    Alarms when the door opens or closes.
    Perfect for monitoring doors while you’re at home.

    •  After the alarm is triggered, there is a built-in 3-second delay for it to reset.

    Middle LED light flashes
    SCHLAGE Deadbolt with Alarm BE469 - ICON 2
    Two short beeps
    Tamper

    Alarms when the lock is disturbed, while locked.

    Senses subtle activity at the lock.Left and right LED lights to flash alternately
    SCHLAGE Deadbolt with Alarm BE469 - ICON 2
    15-second Alarm (90 dB=similar to the volume of your smoke alarm)
    Forced Entry
    Alarms when a significant force pushes against the door, while locked.
    Perfect for nighttime or when you’re away from home.
    • Least sensitive mode – many choose to use this alert setting all the time.
    All lights flash
    SCHLAGE Deadbolt with Alarm BE469 - ICON 2
    Three-minute shrill, steady alarm (90 dB=similar to the volume of your smoke alarm)
  3. Changing the Alarm Mode
    After you power on the alarm, it will be preset to the Forced Entry mode, by default. If you want to change the mode, follow these simple steps:
    • The alarm must first be powered on before changing the alert setting!
    SCHLAGE Deadbolt with Alarm BE469 - Changing the Alarm ModeThe lock will beep when it leaves Programming Mode.
  4. Adjusting the sensitivity Level
    Each alarm mode is preset to a sensitivity level of three. If your alarm is sounding too frequently, or not frequently enough, try changing this setting.
    • You do not need to adjust this setting unless the alarm is sounding too frequently or not frequently enough.
    • If you change the alarm mode, the sensitivity will revert back to the default setting.
    SCHLAGE Deadbolt with Alarm BE469 - sensitivity Level• Each time you press and release the button, the alarm will beep/flash the same number of times as the setting level.
    SCHLAGE Deadbolt with Alarm BE469 - SENSITIVITY 1Number of Flashes/Beeps

MY CODES
Use these tables to record Programming and User Codes that you program into the lock.

  • The Programming Code can be any combination of six numbers entered into the keypad to put the lock in the Programming Mode.
  • The first 4 – 6 numbers (depending on User Code Length) must be different from all of the User Codes currently in the
    lock.
    • Use a pencil to enter the codes in the boxes so you can easily change them later.
  • One Programming Code is programmed into the lock by default. This code can be found on the stickers, one on the back of the Alarm Assembly and one on the back of this guide.

User Codes

  • A User Code can be any combination of 4 – 8 digits entered into the keypad to unlock the lock.
  • The first 4-6 digits must be different from the first 4-6 digits of the Programming Code.
    • Up to 30 User Codes can be stored in the lock at one time.
  • Two User Codes are programmed into the lock by default. These two codes can be found on the stickers, one on the back of the Inside Alarm Assembly and one on the back of this guide.

Best Practices

  • Give each person their own unique User Code.
  • Change User and Programming Codes periodically to ensure security.

Default Codes Locations
Codes are located on the sticker on the back of this guide. They are also located on the back of the Alarm Assembly.

SCHLAGE Deadbolt with Alarm BE469 - FIG 11

• DO NOT remove the sticker from the back of the Alarm Assembly! If you lose your Programming Code, you can reset your lock back to these default codes.

DATE

PROGRAMMING CODE

USER NAMEUSER NAME
Example: John Smith1234
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30

FACTORY DEFAULT RESET

When should you perform a Factory Default Reset?

  • If you want to move the lock to a different door, you need to restore default settings, move the lock to the new door, and then set up the lock again.
  • If you have forgotten your Programming Code, you can restore the default codes.

WARNING

Locate the default Programming and User Codes on the back of this guide or the back of the Alarm Assembly before beginning! Default Programming and User Codes will be restored. All existing User Codes and current Programming Codes will be erased.
CUSTOMER SERVICE CANNOT RETRIEVE LOST DEFAULT CODES! DO NOT RESTORE FACTORY SETTINgS UNLESS YOU CAN LOCATE ThE DEFAULT CODES.

  1. Disconnect the batteries. See Replacing the Batteries on page 4.
  2. Press and hold the Outside Schlage Button.
  3. While holding the Outside Schlage Button, reconnect the batteries.
  4. Release the Outside Schlage Button.
    • If you are moving the lock to a new door, install the lock on that door before continuing.
  5. To check that the lock was reset, press the Outside Schlage Button and enter one of the Default User Codes. See Default Codes Locations on page 10.
  6. If the reset was successful, the lock will perform a setup routine. Wait until the bolt stops moving. The reset and setup are complete.

SCHLAGE Deadbolt with Alarm BE469 - FIG 5

EMERGENcY KEY OVERRIDE

Emergency Key Override can be used when the battery is completely dead, or when no valid User Code is known.
Insert key and rotate to unlock, just like any lock. See
Replacing the Batteries on page 4.
This lock may be rekeyed to match other locks in a residence. Contact a locksmith for assistance.

SCHLAGE Deadbolt with Alarm BE469 - FIG 13

Z-WAVE

This lock is equipped with a Z-Wave® radio.
• The Z-Wave radio is disabled by default to conserve battery life. When the lock is enrolled for the first time, the radio is automatically enabled.
About Z-Wave
This lock is a Security Enabled Z-Wave Product.

  • This lock may be included in any Z-Wave network to enable remote control of the lock, from any manufacturer or service provider.
  • Listening nodes from any manufacturer or service provider can act as repeaters to extend the network range.
  • The lock will have limited functionality if included with a non-secure controller.
  • Replication is the process of copying the network data from a primary controller to a secondary controller on the network. For more information, please see your controller’s documentation.
  • This device supports Anti-Theft. Enabling Anti-Theft protection requires an Anti-Theft enabled controller. For more information, please see your controller’s website or documentation.

Enrolling on a Z-Wave Network
This lock may be included in any Z-Wave network, from any manufacturer.

SCHLAGE Deadbolt with Alarm BE469 - ICON 3
Refer to your home automation system’s documentation or website for more information, then continue.

Enroll your lock:
Extend the bolt on the lock and then perform the following:

SCHLAGE Deadbolt with Alarm BE469 - Enroll

To verify enrollment:

  1. Remove the battery cover. See Replacing the Batteries on page 4.
  2. Disconnect the battery connector.
  3. While watching the inside Schlage button, reconnect the battery connector.
  4. The inside Schlage button will blink if the lock is enrolled.

PROGRAMMING USING Z-WAVE

Many home automation systems support features of the deadbolt including locking, unlocking, and various other programming options.
Refer to your home automation system documentation or website for more information.

TROUBLESHOOTING

PROBLEM

SOUNDSLIGHTS

SOLUTION

I forgot my Programming Code.Check the back of this guide or the back of the Alarm Assembly for default Programming Code.
If needed, restore the lock to factory settings. See Factory Default Reset on page 12.
I need to delete a User Code that I don’t remember.Delete all User Codes. Then add all needed User Codes back into the lock. See Programming the Touchscreen on page 6.
Cannot add a new User Code.Yellow dot flashing1 was not pressed after entering Programming Mode.
2 beeps2 Red30 User Codes already exist. Delete a User Code before adding a new one. See Delete User Code on page 7.
Second User Code entry did not match the first User Code entry.
The new User Code matches the first 4 – 6 digits of the existing Programming Code.
Cannot delete a User Code.Yellow dot flashing2 was not pressed after entering Programming Mode.
2 beeps2 RedFirst User Code entered did not match any current User Code.
Second User Code entered did not match the first User Code entered.
Cannot change Programming Code.Yellow dot flashing3 was not pressed after entering Programming Mode.
2 beeps2 RedSecond Programming Code entered did not match the first Programming Code entered.
First 4 – 6 digits of the new Programming Code match an existing User Code.
Cannot delete all User Codes.Yellow dot flashing6 was not pressed after entering Programming Mode.
The 2nd Programming Code entered was not valid.
User Code does not unlock the lock.1 beep1 RedUser Code entered is not a valid User Code.
User Code cannot be entered after the Outside Schlage button is pressed.1 beepGreen  then

Red

Vacation Mode is enabled. Disable Vacation Mode. See Disable Vacation Mode on page 7.
1 beep1 RedToo many incorrect User Codes have been entered. Wait 30 seconds and try again.
Backlighting does not come on when the Outside Schlage button is pressed and the User Code cannot be entered.Batteries are completely dead and no electronic operations are possible. See Replacing the Batteries on page 4.
The battery tray is not connected.
The cable that runs through the door is not connected. Remove the Alarm Assembly and check the connection. See Step 8 of the Touchscreen Deadbolt with Alarm Installation Instructions for help.

PROBLEM

SOUNDSLIGHTS

SOLUTION

After entering a User Code to unlock the lock, the yellow dot is flashing and there is a delay before unlock.Several beepsOutside yellow dot flashingBattery is low and should be replaced. See

Replacing the Batteries on page 4.

Inside Schlage Button is flashing but no alarm is sounding.Inside Schlage Button flashes every 5 seconds
3 Red when Outside Schlage Button is pressed.3 RedBattery is critical and must be replaced. See Replacing the Batteries on page 4.
Pressing the Outside Schlage button when deadbolt is unlocked does not cause deadbolt to relock.The Lock & Leave feature is not enabled. See Enable/Disable Lock & Leave on page 7.
If you do not want to enable Lock & Leave, then enter a valid User Code to lock the door.
Deadbolt will not extend or retract as expected.1 long beep1 RedAdjust bolt/frame alignment. Browse to

answers.schlage.com for help.

Deadbolt requires two attempts to lock or unlock.GreenDeadbolt/frame alignment is marginal. Adjust door/frame for best operation. Browse to answers.schlage.com for help.
The alarm will not sound.Turn on the Alarm.
Alarm sounds too frequently/ false alarm, or not frequently enough.AlarmThe sensitivity level is too high (at 1 or 2) or too low (at 4 or 5) and should be adjusted. See Adjusting the Sensitivity Level on page 9.
The tamper alert is not sounding.There is a 60-second delay before device alarms to allow you to exit and lock the door. See Alarm Setting Descriptions on page 8.
The bolt was operating smoothly but now is not.The bolt has become soiled. Clean with mild detergent and warm water.
The strike has become worn. Flip the strike over for continued smooth operation.