SMOKE+

A new benchmark for detection performance, detection reliability, consistent performance over time and efficiency of operation

  • Detection Performance
    • Vastly better sensitivity
    • Faster response time
  • Detection Reliability
    • Minimizing nuisance alarms
    • Unsurpassed detection stability under temperature
  • Consistent Performance Over Time
    • Long term exposure to smoke
    • Long term exposure to dust
  • Efficiency of Operation
    • Power consumption per unit area

FLEX

Future Proof expandability for maximum flexibility across a wide variety of applications

PSU StaX

Power supply providing operating power including battery backup for VESDA-E detectors

Auto Pipe Clean StaX

Automated Pipe Cleaning StaX improves performance and minimizes maintenance costs in dusty environments

SECTOR ADDRESSABILITY

Sector (pipe) addressability coupled with the Flair technology provides the best in VEW more cost- effectively than the standard “4 detector” approach

Sector (Pipe) Addressability
  • Enables a single fire zone to be divided into four separate sectors (areas)
  • Allows users to locate the source of smoke more quickly due to smaller search area
  • Provides real time detection by Sector to monitor fire growth
  • Provides four individually configurable alarm levels (Alert, Action, Fire 1 and Fire 2) for each Sector allowing flexible application in different environments
  • More cost effective than “4 detectors” approach for both installation and maintenance

PINPOINT ADDRESSABILITY

Pinpoint tube addressability provides situational awareness to improve response time, efficiency and effectiveness

Pinpoint Addressability
  • VESDA-E pinpoint addressability with flexible tubing (up to 40 holes)
  • VESDA-E VEA is a multichannel addressable system which is able to divide a protected space into sampling locations, enabling the localization of a fire for faster incident response
VESDA-E VEA
  • Fully supervised assured detection with self- monitoring and auto cleaning options
  • Immediate, effective and efficient response minimizing downtime
  • Interruption free operation and maintenance allows uninterrupted and secure business operation
  • Reduces service time by up to 90% due to automatic and centralised maintenance
  • Removes requirements of electrical codes with benign tubes / pipes usage

CONNECT

Flexible networking and programming capabilities that reduce maintenance and monitoring costs through extensive connectivity options and  remote diagnostics

  • Ethernet enables connectivity with Xtralis VSC & VSM4
  • Wi-Fi enables connectivity with hand-held Android & iOS devices
  • USB port allows direct PC connection as well as firmware upgrade
  • VESDAnet supports up to 200 VESDA-E devices on a single loop
  • VESDA-E detectors provide up to 12 relays

TOTAL COST OF OWNERSHIP (TCO)

VESDA-E provides lifetime of value, reliability, and protection – with VESDA-E you can reduce the Total Cost of Ownership

  • Delivering greater Capex value with higher sensitivity and longer pipe runs to reduce the total installation cost
  • Reduces Opex with longer pipe runs enabling convenient mounting, and field replaceable parts
  • Plug & Play installation improves the installation experience and reduces installation cost
  • Design-less pipe networks eliminate design for simple networks and provide direct time and cost saving
  • Backwards compatibility
    • Same footprint, pipe conduit pitch and relays order as VLP/VLS
    • Acts as a gateway into existing VESDAnet
  • Vast monitoring options
    • VSM4
    • iVESDA
    • Remotes

PRODUCT COMPARISON

ParameterVESDA-E VEUVESDA-E VEP-1VESDA-E VEPVESDA-E VESVESDA-E VEA
Fire 1 Lowest Threshold0.001%/m (0.0003%/ft)0.01%/m (0.0031%/ft)1.6%/m (0.5%/ft)
Detection Range0.001 – 20.0% obs/m (0.0003 – 6.25% obs/ft)0.005 – 20% obs/m (0.0016% – 6.25% obs/ft)0.020 – 16% obs/m (0.006 – 4.88% obs/ft)
EN54-20 Max. No. of Holes (Class A / B / C)80 / 80 / 10030 / 40 / 4540 / 80 / 10040 / 80 / 10040
Pipe Length (Linear)400 m (1,312 ft)100 m (328 ft)280 m (919 ft)280 m (919 ft)40 x 100 m (40 x 328 ft)
Pipe Length (Branched)800 m (2,624 ft)130 m (427 ft)560 m (1,837 ft)560 m (1,837 ft)NA
Flow SensingUltrasonicsUltrasonicsUltrasonicsUltrasonicsPressure Transducer and Thermistor
Flow ThresholdsPer PipePer PipePer PipePer PipePer System
StaX SupportYesYesYesYesYes
AddressabilityNoNoNo4 Sectors (pipes)Up to 40 sampling holes
VESDAnetYesYesYesYesYes
iVESDA SupportYesYesYesYesYes
Field Replaceable ChamberYesYesYesYesYes
Ethernet, USBYesYesYesYesYes
Wi-FiYesNoNoNoYes

LEARN MORE: XTRALIS.COM

References

Documents / Resouces

Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.


Related Manuals