Ozone Xt-kja07 Hepa Air Purifier User Manual

Ozone Xt-kja07 Hepa Air Purifier User Manual

ozone logoXT-KJA07 HEPA Air Purifier
User Manualozone XT-KJA07 HEPA Air Purifier

Product User Manual
(Please be subject to 🙂 the actual product
Please real this manual carefully before use
Keep it for reference

After purchasing this product, the customer should follow the corresponding accessories and instructions in the manual.lf there are any mistakes or omissions, please timely feedback to the corresponding distributor. Wish you enjoy using it!

Safety Precautions

In order to ensure that you use this product correctly and safely and avoid harm to you and others, please carefully refer to this manual and comply with it.

  1. Correct and safe use of this product requires proper power sockets.lf your supply is not grounded, please ask a professional electrician to install a suitable socket for you. Please do not modify the plug in any way.
  2. Make sure that the voltage marked by the product is consistent with the local voltage before connecting the power supply.
  3. If the power cord is damaged or the plug is worn, do not use this product. Please arrange replacement it at the repair point designated by the manufacturer.
  4. Do not pull out the plug by pulling the power cord correct way is to hold the plug tightly and pull it out from the socket.
  5. If you do not use it for a long time, you must pull out the plug to avoid electric shock and other accidents.
  6. The power cord plug should maintain solid contact with the socket, so as to avoid fire.
  7. Do not pull out the power plug of the machine when there is flammable gas leakage.
  8. Always unplug the power plug before cleaning, maintenance, and replacement of the filter to prevent electric shock.
  9. Do not block the air inlet and outlet to avoid blocking the normal air outlet.

Extra Precautions:
Thermometers PC868. Infrared Thermometer - Warning 2 Non-standard power adapters.
Thermometers PC868. Infrared Thermometer - Warning 2 Do not contact combustible may not be used. materials or fire sources.
Thermometers PC868. Infrared Thermometer - Warning 2Do not contact water and store the unit in a high temperature (60°C) environment
Thermometers PC868. Infrared Thermometer - Warning 2 Do not slam into the machine.
Thermometers PC868. Infrared Thermometer - Warning 2 Do not dismantle the main motor without authorization (except some operations allowed in the manual).

Notes:
ozone XT-KJA07 HEPA Air Purifier - icon When this product is running not use insecticide or other things, otherwise, it will make the machine’s internal accumulation of pharmaceutical ingredients, adverse to human health.
ozone XT-KJA07 HEPA Air Purifier - icon After switching on the power, the operation panel and the display screen will all be on for 2 seconds before turning off at the same time,a long beep will be heard: when starting up, the PM2.5 sensor reading has a certain lag, please wait patiently for 10s, which is normal.
ozone XT-KJA07 HEPA Air Purifier - icon This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
ozone XT-KJA07 HEPA Air Purifier - icon The appliance is only to be used with the power supply unit provided with the appliance.
ozone XT-KJA07 HEPA Air Purifier - icon If there is any difference in this manual due to the iteration of the product update, please refer to the actual product.

FCC warning:

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter, End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

ItemDetails Parameters
ModeXT-KJA07
Product NameAir PurifierAir Disinfection
Purifier
Air Disinfection and Deodorization Purifier
Configuration optionsAlA2A3
ColorWhite Grey/Black GreyWhite Grey/Black GreyWhite Grey/Black Grey
Rated VoltageDC24VDC24VDC24V
The adapter corresponding PowerHCX4801-2402000E-4PW
Purification Methodfilter, Nrtiyeion
curation
Filter, Negative steratnpuniFile: Nega Negative on UV
sterilization purification
Particulate Matter
CADR
300m3/h300m3/h300m3/h
CCMP4P4P4
Staphylococcus Albus
Removal Rate
100.%100.%100.%
Nature Air Bacteria
Removal Rate
99.%99.%99.%
Applicable Area≈20m2-35m2≈ 20m2- 35m2≈20m2- 35m2
Wind Speed Gearadjustment 3 ge gears3 gears  adjustment3 gears
adjustment
MaterialHIPS+ABSH I PS+ABSHIPS+ABS
NoiseC.58dE560dB–.C..60dB
Product Size4)270*532mm0270*532mm(1)270’532mm
N.W/G.W4.7kg/6.37kg4.7kg/6.37kg4.7kg/6.37kg
WIFI ControlYES