Quick Guide
IND360
Safety Instructions
Intended Use
The IND360 Automation Terminal is used for weighing. Use it exclusively for this purpose. Any other type of use and operation beyond the limits of technical specifications without written consent from Mettler-Toledo, LLC is considered as not intended.
It is essential for the buyer to closely observe the installation information, product and system manuals, operating instructions and other documentation and specifications. MT’s warranty and any liability are expressly excluded for damages caused by noncompliance with the applicable manuals.
Do not use the terminal in any environment or category other than those specified under Specifications.
Documentation
For further details on system configuration and operation, visit www.mt.com/ind-ind360-downloads. For product compliance information, visit http://glo.mt.com/global/en/home/search/compliance.html.
Safety Warnings
DOWNLOAD and READ the Installation Guide BEFORE operating or servicing this equipment and FOLLOW all instructions carefully.
WARNINGS
FOR CONTINUED PROTECTION AGAINST SHOCK HAZARD CONNECT TO PROPERLY GROUNDED OUTLET ONLY. DO NOT REMOVE THE GROUND PRONG.
THE IND360 IS INTENDED TO BE USED FOR PROCESS CONTROL AND IS NOT APPROVED AS A SAFETY COMPONENT. WHEN USED AS A COMPONENT PART OF A SYSTEM, ANY SAFETY CIRCUITS MUST BE INDEPENDENT OF THE IND360 AND REMOVE POWER FROM THE IND360 OUTPUTS IN THE EVENT OF AN EMERGENCY STOP OR EMERGENCY POWER DOWN.
THE IND360 IS NOT INTRINSICALLY SAFE! DO NOT USE IN HAZARDOUS AREAS CLASSIFIED AS DIVISION 1, ZONE 0, ZONE 20, ZONE 1 OR ZONE 21 BECAUSE OF COMBUSTIBLE OR EXPLOSIVE ATMOSPHERES. FAILURE TO COMPLY WITH THIS WARNING COULD RESULT IN BODILY HARM AND/OR PROPERTY DAMAGE.
IND360 MUST NOT BE INSTALLED INTO A DIVISION 2 OR ZONE 2/22 ENVIRONMENT.
DO NOT ACTIVATE POWER OVER ETHERNET (PoE) ON ETHERNET SWITCHES ON THE IND360 NETWORK. ACTIVATING PoE MAY RESULT IN DAMAGE TO THE IND360.
WHEN THIS EQUIPMENT IS INCLUDED AS A COMPONENT PART OF A SYSTEM, THE RESULTING DESIGN MUST BE REVIEWED BY QUALIFIED PERSONNEL WHO ARE FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF ALL COMPONENTS IN THE SYSTEM AND THE POTENTIAL HAZARDS INVOLVED. FAILURE TO OBSERVE THIS PRECAUTION COULD RESULT IN BODILY HARM AND/OR PROPERTY DAMAGE.
DO NOT INSTALL, DISCONNECT OR PERFORM ANY SERVICE ON THIS EQUIPMENT BEFORE POWER HAS BEEN SWITCHED OFF AND THE AREA HAS BEEN SECURED AS NON-HAZARDOUS BY PERSONNEL AUTHORIZED TO DO SO BY THE RESPONSIBLE PERSON ON-SITE.
ONLY THE COMPONENTS SPECIFIED IN THE IND360 DOCUMENTATION CAN BE USED IN THIS TERMINAL. ALL EQUIPMENT MUST BE INSTALLED IN ACCORDANCE WITH THE INSTALLATION INSTRUCTIONS DETAILED IN THE INSTALLATION MANUAL. INCORRECT OR SUBSTITUTE COMPONENTS AND/OR DEVIATION FROM THESE INSTRUCTIONS CAN IMPAIR THE SAFETY OF THE TERMINAL AND COULD RESULT IN BODILY HARM AND/OR PROPERTY DAMAGE.
BEFORE CONNECTING/DISCONNECTING ANY INTERNAL ELECTRONIC COMPONENTS OR INTERCONNECTING WIRING BETWEEN ELECTRONIC EQUIPMENT ALWAYS REMOVE POWER AND WAIT AT LEAST THIRTY (30) SECONDS BEFORE ANY CONNECTIONS OR DISCONNECTIONS ARE MADE. FAILURE TO OBSERVE THESE PRECAUTIONS COULD RESULT IN DAMAGE TO OR DESTRUCTION OF THE EQUIPMENT AND/OR BODILY HARM.
ONLY PERMIT QUALIFIED PERSONNEL TO SERVICE THE TERMINAL. EXERCISE CARE WHEN MAKING CHECKS, TESTS AND ADJUSTMENTS THAT MUST BE MADE WITH POWER ON. FAILING TO OBSERVE THESE PRECAUTIONS CAN RESULT IN BODILY HARM AND/OR PROPERTY DAMAGE.
Specifications and Operator Interface
Specifications
Enclosure Types | DIN Rail mount, ABS plastic with automatic grounding springs at the rear side of the enclosure, the unit also includes a green plastic locking clip. |
Panel-mount stainless steel front panel with a frame which is compatible to the IND331 mounting dimensions. The panel is structured such that the electronics may be mounted with the display or may be remotely mounted on a DIN (Omega) rail. | |
Harsh environment desk/wall/column-mount type 304L stainless steel enclosure with Versa 100 mounting holes in the rear of the enclosure using. Mounting brackets are exactly the same as the Model IND570. | |
Dimensions (w × h × d) | DIN-Rail mount: 40 x 135 x 100 /1.6 x 5.1 x 3.9 |
Panel Mount: 175 x 94 x 16 / 6.9 x 3.7 x 0.6 | |
Harsh Environment: 275 x 85 x 200 / 10.8 x 3.3 x 7.9 | |
Shipping Weight | DIN-Rail mount: 0.5 / 1.1 |
Panel Mount: 1.7 / 3.7 | |
Harsh Environment: 3.6 / 7.9 | |
Environmental Protection | DIN-Rail mount: IP20 type 1 |
Panel-mount panel display: IP65 | |
IND360 Harsh Environment model: IP69K. | |
Operating Environment | −10° to 50° C (14° to 122° F) at 10% to 90% relative humidity, non-condensing |
Legal for Trade | −10° to 40° C (14° to 104° F) at 10% to 90% relative humidity, non-condensing |
Hazardous Areas | IND360 is not yet certified for used in hazardous areas |
AC Input Power (Harsh and panel-mounmodels) | Operates at 100–240 VAC, 49–61 Hz |
Peak current at startup: 750 mA | |
DC Input Power (DIN Rail mount and Panelmount models) | Operates at 20-28 VDC 1); 12W 2) 1) Power supply short circuit protection time shall be equal or longer than 100ms. 2) 18W when 5 … 8 POWERCELLs are connected |
Scale Types | Analog load cells: up to 8×350 Ω or 20×1000 Ω; 1~4mV/V or APW (Automated Precision Weighing) module and high-precision platforms that include Advanced Setup Mode or Up to 8 POWERCELL load cells. |
Analog Load Cell Excitation Voltage | 5 VDC |
Automation interface Update Rate | IND360 analog: 960 Hz IND360 POWERCELL: 100Hz for 1~4 LCs; 50 for 4~8 LCs IND360 Precision: 92 Hz |
Display | DIN Rail mount version: 1.04” green OLED Panel mount version: 4.3” color TFT Harsh version: 4.3” color TFT |
Keypad | DIN Rail mount version: 4 keys (Up, Down, Left, Enter); 0.9 mm thick polyester overlay (PET) with 0.178mm thick polycarbonate display lens |
Panel mount and harsh version: 5 keys (Up, Down, Left, Right, Enter); 0.9 mm thick polyester overlay (PET) with 0.178mm thick polycarbonate display lens | |
Communication | Standard Interfaces Ethernet Port: Ethernet TCP/IP interface for service setup (web interface) and basic control from PC |
Optional Automation Interfaces (none or one of the following) Dual Industrial Ethernet Port for PROFINET and EtherNet/IP which also support Media Ring Profile (PROFINET) and Device Level Ring (EtherNet/IP) Interface for PROFIBUS DP communication Interface for Modbus RTU communication | |
Optional Analog and Digital IOs (none or one of the following) 4~20mA Analog Output | |
4~20mA Analog Output, 3 Discrete Inputs, 4 Discrete outputs, Solid State 5 Discrete Inputs, 8 Discrete Outputs, Solid State | |
Approvals | Weights and Measures IND360 Analog and IND360 POWERCELL Europe: Class , TC11949 T11060 USA: Class Ⅲ n max. 10,000 CC No. 21-002 Canada: Class Ⅲ n max. 10,000 AM-6161 China: Class n max. 10,000 IND360 Precision Europe: Class , , TC11949 T11060 USA: Class Ⅲ n max. 10,000 CC No. 21-002 Canada: Class Ⅲ n max. 10,000 AM-6161 Product Safety UL, cUL, CE, FCC, CB |
DIN Rail Version Interface Features
Operator Interface, Front and Top
Display Features
Front Panel and Display Features, Panel-Mount and Harsh Environment Versions
Pushbutton Functions, All Versions
Scale Function Keys, Weighing Mode | DIN | Panel/Harsh | Scale Function Keys, Menu and Data Entry Modes |
When a container is on the scale, memorize tare value and display a net zero weight | Scroll up in a menu display | ||
Capture a new gross zero reference point | Scroll left in a menu display | ||
Clear the current tare value; the display will revert to the gross weight value | Scroll down in a menu display | ||
Transmits data from the terminal; long press enters Operator Menu [For details on the ePrint function, reference the User’s Guide] | Confirms an entry and/or moves to the next item in a menu display or to next lower menu level Moves cursor to the right | ||
Select softkey [Panel and harsh environment versions only] | Move to next lower menu level; select data entry field; confirm value entry. |
Operator Menu Icons [Accessible only if terminal is not in Approved Mode]
Information Recall | Access system information | |
Error Message | Display current error messages (e.g. Scale underload) | |
Enhanced Resolution | Display weight value with additional decimal place | |
Scale Setup | Set capacity and increment; calibrate zero and span; configure filter; reset calibration values | |
Application | Enable/disable embedded Application | |
Terminal | Display terminal settings, such as serial number | |
Communication | Enable/disable web server, PC applications, and ePrint | |
Maintenance | Access terminal maintenance functions |
Operating Instructions
Weights and Measures Approved Mode
When the terminal is used in metrologically-approved applications, it is sealed with a paper or wire seal. Do not tamper with the seal.
Two DIP switches, 1 and 2, are accessible on the top of the IND360, and inside the IND360 Harsh Environment model’s enclosure. The table below shows the location of the DIP switches and summarizes their functions.
Panel and DIN Rail Mount Enclosures | Switch 1 | Switch 2 | Function | ||
Standard (Automation) Mode | |||||
OFF | OFF | Normal operation | |||
OFF | ON | Master reset of all data during transmitter power-up | |||
Harsh Environment Enclosure | |||||
Approved Mode (for sales to public) | |||||
ON | OFF | Legal-for-trade mode; calibration data protected | |||
ON | ON | Reset of all except calibration (adjustment) data during transmitter power-up |
Web Browser Access to IND360 DIN Rail Mount Model
The IND360 can be configured and controlled directly from its front panel interface, or via a web browser interface. The interface is also a diagnostic tool for service purposes. For web browser access:
- IND360: Web Server must be Enabled in Access Security menu.
- PC, IND360: physically connected to the same network
- PC, IND360: IP addresses configured correctly:
PC: Windows Control Panel | Network and Internet | Connections
IND360: Default – 192.168.0.8
On-Screen Menus
Menu Navigation
Within the Operator Menu, the Scale Function Keys work as follows:
Data Entry, DIN Rail Mount Version
When an on-screen item requires data entry, the Scale Function Keys work as follows:
Accessing and Exiting the Softkeys, Harsh Environment and Panel-Mount Versions
Accessing and Exiting the Operator Menu
Basic Functions
Zero
Tare
Tare Operation
Clear Tare
ePrint
Diagnostics and Maintenance
Common Errors
Overcapacity | Terminal cannot execute commands because the weight on the scale is over the adjusted (calibrated) capacity. The weight display shows blanked condition: |
Undercapacity | Terminal cannot execute commands because the weight is under the current captured zero. The weight display will show an under zero condition: |
Motion | If motion is detected when a command is received, the IND360 will wait for a no-motion condition. If a stable (no motion) weight condition is reached, the command is executed. If a no-motion state cannot be reached, the command is aborted and a “Scale In Motion” error displays. |
Failure to Zero | If pushbutton zero is enabled and the operator presses the ZERO scale function key, these common errors may occur: Zero Failed-Range: Gross weight outside the programmed zero range Zero Failed-Net Mode: zero failed because scale is in net mode Scale In Motion: zero failed due to motion on scale If EEE is shown on display, the terminal has not captured a zero reference at power-up |
Failure to Print | When an operator attempts to use the print function, these common errors could occur: ePrint improperly configured Scale In Motion: print failed due to motion on scale |
Function Disabled | Error occurs if an operator attempts to access a disabled function. |
Access Denied. User Not Authorized | Occurs if an operator attempts to access an unauthorized function. |
Cleaning the Terminal
Use a soft, clean cloth and mild glass cleaner. Do not spray cleaner directly onto terminal. Do not use industrial solvents such as acetone.
www.mt.com/ind-IND360
For more information
Mettler-Toledo
Im Langacher 44 8606 Greifensee Switzerland
Phone 800 438 4511
© 2021 Mettler-Toledo, LLC 30654686 Rev. 00, 01/2021
METTLER TOLEDO IND360 Quick Guide
30654686XXXXXXXX | 00 |01/2021
Documents / Resources
METTLER TOLEDO IND360 Ultra Fast Processing Weighing Terminal [pdf] User Guide IND360, Ultra Fast Processing Weighing Terminal, IND360 Ultra Fast Processing Weighing Terminal, Weighing Terminal, Terminal |