AHFP12A 12v Wall Mount Diesel Pump Kit
Product Information:
Product Name: Macnaught 12V Wall Mount Diesel
Pump Kit (AHFP12A)
Description: The Macnaught 12V Wall Mount
Diesel Pump Kit is a self-priming, positive displacement, rotary
vane pump designed for transferring diesel fuel. It operates on 12V
DC and has a maximum flow rate of 60 liters per minute. The pump
comes with a wall mount plate, automatic nozzle, fuel meter,
4-meter power cable with fuse holder, and alligator clips. It also
features a built-in bypass valve to maintain operating pressure
below 2 Bar (29psi) and has a 30-minute duty cycle. The product is
compatible with Macnaught HA1S Diesel filter for better
performance.
Additional Products: Macnaught offers a range
of retractable hose reels, fuel nozzles, fuel meters, air-operated
or manual oil pumps, and greasing equipment to meet various fluid
handling needs.
Product Usage Instructions:
- Assembly:
- Select a 1 I/D suction hose or suction tube compatible with
diesel and with a pressure rating above 3.5 bar (50psi). - Securely fit the pump unit to the desired location using the
wall mount plate. - Connect the delivery hose to the outlet on the meter body.
- Connect the remaining end of the delivery hose to the automatic
nozzle.
- Insert the suction hose into the fuel tank. Ensure the tank or
barrel is anchored to prevent tipping. - Connect the alligator clips on the power cord to a battery
capable of delivering the necessary voltage and current. Attach the
red clip to the positive (+) battery terminal and the black clip to
the negative (-) battery terminal or vehicle frame.
- Before use, clean any dirt or moisture from the nozzle or
hoses. - Insert the nozzle into the container to be filled and insert
the suction hose into the diesel storage tank if applicable. - Avoid using a patch cord to extend the power cables to prevent
sparks that could cause a fire. - The meter displays both batch total and accumulative totals
when fluid passes through it. - To reset the batch total to zero, rotate the reset knob on the
meter. - Do not let the pump run dry or run in bypass mode for more than
2 minutes to prevent damage.
Please refer to the complete instruction manual provided with
your product for more detailed information and safety precautions.
If you need further assistance, contact your local Macnaught
distributor.
AHFP12A_2022
INSTRUCTION MANUAL
12V WALL MOUNT DIESEL PUMP KIT
AHFP12A
INSTRUCTION MANUAL
12V WALL MOUNT DIESEL PUMP KIT
AHFP12A
INTRODUCTION
Thank you for purchasing a Macnaught 12 volt Wall Mount Diesel Pump Kit.
The Macnaught Wall Mount Diesel Pump Kit is supplied, complete with Wall Mount plate, Automatic Nozzle, Fuel Meter, 4M power cable with fuse holder and alligator clips.
Wall mount plate
Mechanical meter
Pump unit
Macnaught also have a complete range of retractable hose reels, fuel nozzles, fuel meters, air operated or manual oil pumps and a full range of greasing equipment available to suit all of your fluid handling requirements.
GENERAL INFORMATION
This manual assists you in operating and maintaining your high flow electric diesel fuel pump. The information contained will help ensure many years of dependable trouble free operation.
Please read and retain this instruction manual to assist you in the operation and maintenance of this quality product. If you require any further assistance please contact your local Macnaught distributor.
DESCRIPTION
This diesel transfer pump is designed to reliably transfer diesel. The pump is a self priming, positive displacement, rotary vane pump operating on 12V DC. The pump will deliver up to 60 litres per minute, has a built-in bypass valve that keeps the operating pressure below 2 Bar (29psi) and the motor has a 30 minute duty cycle
If required Macnaught recommends that you use the Macnaught HA1S Diesel filter.
CAUTION
ONLY USE this pump with Diesel failure to do so may cause personal injury, damage the pump and would also void pump warranty. If the inline fuse supplied with this pump is removed warranty will be void.
Delivery hose Electric cable assembly
Auto nozzle
ASSEMBLY
Use oil resistant pipe sealant or Teflon® tape on all pipe threads.
1. Select a 1″ I/D suction hose or suction tube which is compatible with Diesel and has a pressure rating above 3.5 bar (50psi).
2. Fit the Pump unit securely to the desired location.
3. Connect the delivery hose to the outlet on the meter body.
4. Connect the remaining end of the delivery hose to the automatic nozzle
PUMP INSTALLATION
1. Insert the suction hose into to the fuel tank.
NOTE: Tanks or barrels should be anchored to prevent tipping in both the full and empty conditions.
2. Connect the alligator clips on the power cord to a battery capable of delivering the necessary voltage and current (see the Technical Data, back page of this manual)
a) Attach the RED clip to the positive (+) battery terminal. b) Attach the BLACK clip to the negative (-) battery terminal or to the vehicle frame.
2
macnaught | instruction manual
12V HIGH FLOW DIESEL PUMP KIT
AHFP12A
INSTRUCTION MANUAL
OPERATION
NOTE: Avoid sparks that could cause a fire: DO NOT use a patch cord to extend the power cables.
METER OPERATION
Both the batch total and accumulative totals turn simultaneously when fluid passes through the meter.
To reset the batch total to zero, rotate the reset knob.
DO NOT let the pump run dry or run in by-pass mode for more than 2 minutes or damage may occur.
1. Before use, wipe off any dirt or moisture that may have accumulated on the nozzle or hoses.
2. Insert nozzle into the container to be filled. Insert suction hose (if applicable) into the diesel storage tank.
3. Switch the motor on. 4. Operate the nozzle lever to dispense fluid. 5. When the desired amount of fluid has been dispensed,
release nozzle lever to stop flow. 6. Immediately switch motor off. 7. Nozzle and hoses should be kept clean and dry when
not in use.
MAINTENANCE
Important: Do not modify any part of the unit or any warranty on the product will be automatically void.
1. Inspect and clean the basket strainer located in the pump regularly. 2. Always clean the battery terminals and clips before use
to ensure a good connection. 3. Always relieve the line pressure by opening the nozzle,
draining hose. Disconnect power before starting any pump maintenance 4. Hoses should be inspected regularly. (Replace if found to be cracked or worn) 5. The rotor and vanes will eventually wear. They should be replaced if pump performance degrades. (refer to trouble shooting guide)
METER FIELD CALIBRATION
Calibration may be required depending on installation or after disassembly, metering different fluids or where meter wear has occurred.
NOTE: You will need to use an accurate measuring container with graduations up to at least 19 litre capacity.
CALIBRATION PROCEDURE
1. Set the batch total to Zero 2. Dispense 19 liters into your accurate measuring container 3. Check the total shown on the meter and compare with the actual total dispensed as shown in the container. 4. Adjust the calibration screw as required a) Turn the screw anti-clockwise to reduce the indicated amount b) Turn the screw clockwise to increase the indicated amount
Note: One full turn of the screw will change the indicated amount approximately 2 liters
5. Repeat steps 1 – 4 until meter calibration is acceptable.
macnaught.com.au
3
INSTRUCTION MANUAL
12V WALL MOUNT DIESEL PUMP KIT
AHFP12A
(Strainer removal or replace)
(Correct vane and rotor orientation)
NOTE: Assemble with dimple up and fit vanes in the correct orientation as shown.
1
4
macnaught | instruction manual
12V HIGH FLOW DIESEL PUMP KIT
AHFP12A
21
(Correct seal orientation)
INSTRUCTION MANUAL
(Poppet valve assembly / disassembly)
15 20
A B
8 90°
A
90°
B
90°
18
C
A PUSH
B TURN 90°
C EXIT
Peso indicativo
Rev.
1
2
3
4
5
ioni
-mK 3390.5955 kg Approvato
RM n°
macnaught.com.au
5
INSTRUCTION MANUAL
12V WALL MOUNT DIESEL PUMP KIT
AHFP12A
PUMP PART LIST
Item
Description
1
pump body pb 60 ltd
Qty 1
2
coupling motor flange pb ltd 1
4
screw tcce m5x16
2
5
12v motor for pb 60/85
1
8
hex spacer mf m5x25
2
9
motor cover ip55 pb1 60l
1
10
cable gland pg 13.5
1
11
cable gland nut gmp-gl 13.5 1
12
plate washer 5x10x1
2
Item
Description
13
self-locking nut m5
14
switch 22×30 + cover
15
swivel locking plate
16
screw te m5x12 flanged
17
o-ring 2015 nbr
18
by-pass valve
19
rotor ø45
20
small vane
21
pin 3x3x15 uni 6604-b
Qty 2 1 1 5 1 1 1 5 1
Item
Description
22
shaft seal ø19
Qty 1
23
by-pass spring
1
24
black reinforced bypass cap 1
25
cable with clamps + fuse
1
26
inox filter 16×49
1
27
filter seal
1
28
o-ring nbr70 body pump
1
AVAILABLE ACCESSORIES
Automatic nozzle / Manual nozzle Telescopic suction tube with strainer – ATS205
6
macnaught | instruction manual
12V HIGH FLOW DIESEL PUMP KIT
AHFP12A
INSTRUCTION MANUAL
METER PART LIST
3 2
21 27
28
25
26
20
Item
Description
Qty
2 chamber lid
1
3 meter body
1
20 measure chamber
1
21 adjustament bypass screw
1
27 reset knob
1
28 meter label
1
AVAILABLE ACCESSORIES
For seal kits:
For fascia and reset button set:
Order AMFM-1K (for pumps manufactured before Sep 2022) Order AMFM-1K-N (for pumps manufactured after Sep 2022) Order AMFM-2K (for pumps manufactured before Sep 2022)
Order AMFM-2K-N (for pumps manufactured after Sep 2022)
macnaught.com.au
7
INSTRUCTION MANUAL
12V WALL MOUNT DIESEL PUMP KIT
AHFP12A
TROUBLE SHOOTING GUIDE
Problem Pump fails to start
Cause 1) Suction hose/tube has a blockage 2) Outlet is blocked
3) Bypass poppet not closing 4) Vanes sticking
Pump vibrates but does not turn on Low Flow Motor overheating Motor not turning on Pump leaking out of weep hole
5) Excessive vane or rotor wear 6) Leak from front o’ring
1) Dirt jammed inside the pump 2) Faulty motor
3) Broken drive key
1) Blocked strainer 2) Restriction on the inlet or outlet 3) Excessive rotor or vane wear 4) By pass poppet blocked 5) Low fluid level in tank 1) Fluid too thick (viscous) 2) Motor running longer than 30 minutes
3) Blocked suction hose 4) Blocked strainer 1) Poor electrical connection 2) Battery low or faulty 3) Blown or faulty fuse 4) Faulty switch 1) Worn or damaged shaft seal 2) Fluid compatibility
METER TROUBLE SHOOTING GUIDE
Problem
Cause
Meter not reading
1) Blockage in the fluid chamber 2) Meter installed incorrectly
Batch total does not reset
Meter leaking
1) Reset knob not correctly engaged 2) Register is broken 1) Damaged o’ring seal
8
macnaught | instruction manual
Solution 1) Clear blockage from suction hose/tube 2) Check outlet hose and nozzle for blockage and correct operation 3) Check bypass valve is closing correctly 4) Check vanes are sliding freely in the slots (remove burrs or replace vanes if required) 5) Replace rotor and/or vanes 6) Check o’ring for correct sealing, replace if required 1) Clean pump chamber 2) Replace pump
3) Replace drive key
1) Clean or replace strainer 2) Incorrect size hoses used on inlet or outlet 3) Replace worn or damaged components 4) Check poppet valve for correct operation 5) Fill tank 1) Fluid to be no thicker than Diesel 2) Pump must only run for 30 minutes before cooling 3) Clean blockage from suction hose 4) Clean strainer 1) Clean terminals and battery clamps 2) Check battery 3) Check pump and/or replace fuse 4) Replace switch 1) Replace seal 2) Only use compatible fluid
Solution
1) Clear blockage from fluid chamber
2) Check the meter orientation (flow must be in direction of the arrow 1) Fit reset knob correctly 2) Replace meter 1) Replace o’ring
12V HIGH FLOW DIESEL PUMP KIT
AHFP12A
INSTRUCTION MANUAL
PUMP SPECIFICATIONS
Maximum Flow Nominal pressure Voltage Maximum Current Duty cycle Fuse Inlet / Outlet Temperature Wetted materials Maximum prime height Motor protection rating
AHFP12A
60ltr/min 2 bar
12 Volt 26 amp 30 min 40 amp 1″ BSP (F) -20 deg C / +50 deg C Zinc plated steel, Cast iron, Sintererd steel, POM-C, NBR
2m IP55
METER SPECIFICATIONS
Meter Type Flow rate Maximum pressure Accuracy Inlet / Outlet Temperature Display Weight Fluid Compatibility Materials of construction
Nutating disc 20 – 120 ltr/min 3.5bar (50psi)
+/- 1% 1″ BSP (F) -20 deg C / +50 deg C
4 digit 1.8 kg Diesel NBR, PBT, Brass, Steel
macnaught.com.au
9
INSTRUCTION MANUAL
12V WALL MOUNT DIESEL PUMP KIT
AHFP12A
ELECTRIC DIAGRAM
switch ON-OFF fuse motor
Electric cable selection table (minimum requirement):
Pump Model AFP24A AFP12A
AHFP12A
AHFP85L-12V
Fluid Flow Rate diesel 40LPM diesel 40LPM
diesel 60LPM
diesel 85LPM
Power Supply 12VCD 12VDC
12VDC
12VDC
Fuse 15A 30A
40A
40A
Total Cable Lenght 0-4 m 4-6m 0-4 m 4-6m 4-8m 0-4 m 4-6m 6-10m 0-4 m 4-6m 6-10m
Minimum Wire Section
2.5 mm2
11AWG
4 mm2
9AWG
2.5 mm2
13AWG
4 mm2
11AWG
6 mm2
9AWG
6 mm2
9AWG
10 mm2
7AWG
16 mm2
5AWG
6 mm2
9AWG
10 mm2
7AWG
16 mm2
5AWG
10 macnaught | instruction manual
INSTRUCTION MANUAL
12V2 HIGH FL3OW DIES4 EL PUM5 P KIT 6
7
8
AHFP12A
1
2
3
4
5
6
7
PUM1P5D3I-MPEBN0S/1IO6N0/S85 153 – PB0/1 60/85
112 111252 – PB0 60/85 152 – P1B7016-0/PB815 60/85 171 – PB1 60/85
INLET 1″BSP-G INLET 1″BSP-G
OUTLET 1″BSP-G OUTLET 1″BSP-G
14 14
112 112
METER DIMENSIONS
2
3
1
2
3
4 4
90
48 33
193 – PB0 60/85 263 – PB1 6900/85 48 33
193 – PB0 60/85
263 – PB1 60/85
Tolleranze generali
Peso indicativo
Rev.
1
2
3
4
5
6
7
8
Revisioni
UNI EN 22768-mK SW-Massa
Disegnato
kg Approvato
RM n°
Ing.A.Zanzanell
Data
i Data
22/10T/o2lle0r1an8ze
Data
generali 22/10/201P8eso
Firma indicativo
Rev.
1
2
3
4
5
6
7
Revisioni
–
CompUoNnIeEnNte2A2d7a6m8-mPuKmpSsW- -MasMsaateriale
Disegnato
kg Approvato
RM
n°
–
Ing.A.Zanzanell
Data Denominazione
i Data
Data
22/10/2018
22/10/2018
Firma
PB1 60 12V LTD
Proprietà
– Componente Adam PumpsCo-dice Materiale
PB16A24- 00
Foglio
1 di 1
Denominazione
PB1 60 12V LTD Proprietà della ADAM PUMPS Spa – Senza autorizzazione scritta della stessa il presente disegno non potrà essere comunque ut
costruzione dell’ oggetto rappresentato, nè venire comunicato a terzi o riprodotto. La società proprietaria tutela i propri diritti a ri
Proprietà
5
6 Codice
PB16A7 2400
18Fogl
Proprietà della ADAM PUMPS Spa – Senza autorizzazione scritta della stessa il presente disegno non potrà essere comu costruzione dell’ oggetto rappresentato, nè venire comunicato a terzi o riprodotto. La società proprietaria tutela i propri d
5
6
7
1″ BSP-G 1″ BSP-G
macnaught.com.au 11
NOTES
Note:
This product should be disposed of according to all applicable local and national government environment regulations and guidelines.
Built to last since 1948
Macnaught Pty Ltd 41-49 Henderson Street Turrella NSW 2205
Ph: 1800 185 102 Fax: 1800 186 402 E-mail: [email protected]
For Warranty Terms and Conditions see www.macnaught.com.au For a list of Australian Service Centres see www.macnaught.com.au

















